Sine-fit procedure for unevenly sampled, multiply clocked signals

被引:5
|
作者
Milotti, E
机构
[1] Univ Udine, Dipartimento Fis, I-33100 Udine, Italy
[2] Ist Nazl Fis Nucl, Sez Trieste, I-33100 Udine, Italy
关键词
D O I
10.1016/j.jcp.2004.07.005
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
When signals are unevenly sampled and homodyne or heterodyne setups are used that involve multiple clocks, it is not possible to use the standard algorithms to produce accurate spectral density estimates. The PVLAS experiment is an example of such an experimental scheme and here it is shown how to implement an algorithm which generalizes the standard sine-fit and Lomb-Scargle procedures to obtain both amplitude and phase of important Fourier components of the physical signal, with an application to PVLAS data. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:134 / 149
页数:16
相关论文
共 30 条
  • [1] Comparison of Sine-Fit Algorithms for Real Signals
    Orhan, Recep
    Serbes, Ahmet
    2018 26TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2018,
  • [2] One-Bit Sine-Fit
    Carbone, Paolo
    Schoukens, Johan
    De Angelis, Alessio
    Santoni, Francesco
    Comuniello, Antonella
    Moschitta, Antonio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [3] Characterization of ΔΣ converters by means of the sine-fit algorithm
    Nunzi, E.
    2006 IEEE Instrumentation and Measurement Technology Conference Proceedings, Vols 1-5, 2006, : 1051 - 1055
  • [4] The effective resolution measurements in scope of sine-fit test
    Hejn, K
    Pacut, A
    Kramarski, L
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (01) : 45 - 50
  • [5] The effective resolution measurement in scope of sine-fit test
    Hejn, K
    Kramarski, L
    Pacut, A
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 1148 - 1151
  • [6] Improved interpolation of unevenly sampled heart rate signals
    Mateo, J
    Laguna, P
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 137 - 140
  • [7] Time-base nonlinearity determination using iterated sine-fit analysis
    Stenbakken, GN
    Deyst, JP
    WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 1335 - 1340
  • [8] Time-base nonlinearity determination using iterated sine-fit analysis
    Stenbakken, GN
    Deyst, JP
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (05) : 1056 - 1061
  • [9] Digital processing of unevenly sampled signals by means of fitted splines
    Getmanov, VG
    MEASUREMENT TECHNIQUES, 2003, 46 (06) : 562 - 567
  • [10] Bayesian estimation of time delays between unevenly sampled signals
    Harva, Markus
    Raychaudhury, Somak
    NEUROCOMPUTING, 2008, 72 (1-3) : 32 - 38