Unobtrusive Vital Sign Monitoring in Automotive Environments-A Review

被引:93
作者
Leonhardt, Steffen [1 ]
Leicht, Lennart [1 ]
Teichmann, Daniel [2 ]
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Chair Med Informat Technol, D-52076 Aachen, Germany
[2] MIT, IMES, Boston, MA 02139 USA
关键词
unobtrusive monitoring techniques; car seat; driver state monitoring; vehicle; electrocardiogram; steering wheel; capacitive electrocardiogram; magnetic impedance; eddy currents; ballistocardiography; photoplethysmography; PPG imaging; infrared thermography; RADAR; FACIAL EXPRESSION RECOGNITION; HEART-RATE-VARIABILITY; MEASUREMENT SYSTEM; MOTION ARTIFACTS; ECG MEASUREMENT; NONCONTACT; STRESS; RADAR; VIDEO; CAR;
D O I
10.3390/s18093080
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This review provides an overview of unobtrusive monitoring techniques that could be used to monitor some of the human vital signs (i.e., heart activity, breathing activity, temperature and potentially oxygen saturation) in a car seat. It will be shown that many techniques actually measure mechanical displacement, either on the body surface and/or inside the body. However, there are also techniques like capacitive electrocardiogram or bioimpedance that reflect electrical activity or passive electrical properties or thermal properties (infrared thermography). In addition, photopleythysmographic methods depend on optical properties (like scattering and absorption) of biological tissues and-mainly-blood. As all unobtrusive sensing modalities are always fragile and at risk of being contaminated by disturbances (like motion, rapidly changing environmental conditions, triboelectricity), the scope of the paper includes a survey on redundant sensor arrangements. Finally, this review also provides an overview of automotive demonstrators for vital sign monitoring.
引用
收藏
页数:38
相关论文
共 182 条
[61]  
Izumi S., CONTACT LESS HEART R
[62]   MONITORING OF THE BALLISTOCARDIOGRAM WITH THE STATIC CHARGE SENSITIVE BED [J].
JANSEN, BH ;
LARSON, BH ;
SHANKAR, K .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) :748-751
[63]  
Jeanne V., 2013, P INT C CONN VEH EXP
[64]  
Jeong I.C., 2007, P 2007 IEEE INT VEH
[65]  
Jung SJ, 2012, 2012 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), P305, DOI 10.1109/ICCE.2012.6161880
[66]   Driver fatigue and drowsiness monitoring system with embedded electrocardiogram sensor on steering wheel [J].
Jung, Sang-Joong ;
Shin, Heung-Sub ;
Chung, Wan-Young .
IET INTELLIGENT TRANSPORT SYSTEMS, 2014, 8 (01) :43-50
[67]   A new look at the essence of the imaging photoplethysmography [J].
Kamshilin, Alexei A. ;
Nippolainen, Ervin ;
Sidorov, Igor S. ;
Vasilev, Petr V. ;
Erofeev, Nikolai P. ;
Podolian, Natalia P. ;
Romashko, Roman V. .
SCIENTIFIC REPORTS, 2015, 5
[68]  
Kao TYJ, 2013, I C COMP SYST APPLIC
[69]   Estimation of Respiratory Rate From Photoplethysmographic Imaging Videos Compared to Pulse Oximetry [J].
Karlen, Walter ;
Garde, Ainara ;
Myers, Dorothy ;
Scheffer, Cornie ;
Ansermino, J. Mark ;
Dumont, Guy A. .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2015, 19 (04) :1331-1338
[70]   A systematic review of novel technology for monitoring infant and newborn heart rate [J].
Kevat, Ajay C. ;
Bullen, Denise V. R. ;
Davis, Peter G. ;
Kamlin, C. Omar F. .
ACTA PAEDIATRICA, 2017, 106 (05) :710-720