Comparative Study of C-arms for Intraoperative 3-dimensional Imaging and Navigation in Minimally Invasive Spine Surgery Part I Applicability and Image Quality

被引:8
作者
Klingler, Jan-Helge [1 ]
Sircar, Ronen [1 ]
Scheiwe, Christian [1 ]
Kogias, Evangelos [1 ]
Volz, Florian [1 ]
Krueger, Marie T. [1 ]
Hubbe, Ulrich [1 ]
机构
[1] Freiburg Univ, Dept Neurosurg, Med Ctr, Breisacher Str 64, D-79106 Freiburg, Germany
来源
CLINICAL SPINE SURGERY | 2017年 / 30卷 / 06期
关键词
C-arm; image quality; intraoperative imaging; minimally invasive surgery; navigation; spine; 3-dimensional imaging; PEDICLE SCREW PLACEMENT; CONVENTIONAL FLUOROSCOPY; TRAUMA CARE; ACCURACY; FEASIBILITY; GUIDANCE; FUSION;
D O I
10.1097/BSD.0000000000000186
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: This was a retrospective analysis. Objective: This study compares 2 different 3-dimensional (3D) C-arm devices for intraoperative imaging and navigation with regard to clinical applicability and image quality. Summary of Background Data: Minimally invasive spine surgery requires intraoperative imaging techniques to adequately visualize the unexposed spine. For this purpose, mobile 3D C-arms became available along with the evolution of intraoperative navigation techniques. Methods: The C-arm devices Siremobil Iso-C 3D (Siemens) and Vision FD Vario 3D (Ziehm) perform an automated orbital rotation around the patient acquiring a 3D image set out of multiple successive fluoroscopic images. We report on technical specifications of the C-arms and our daily experience regarding clinical applicability. Furthermore, 5 spine surgeons evaluated blinded triplanar planes of 40 cervical, thoracic, and lumbar 3D scans that were obtained during routine surgery regarding usability for navigation. We assessed the delineation of cortical bone, artifacts, and overall image quality using a 0-10 numeric rating scale. Results: The Siremobil Iso-C 3D requires 128 seconds for its 190-degree scanning arc with equidistant isocenter. The Vision FD Vario 3D performs an elliptical scanning arc and completes its 135-degree scan in 64 seconds; furthermore, it features a flat panel detector and fully digital imaging. The smaller dimensions of the Vision FD Vario 3D made it easier to maneuver in the operating room compared with the more bulky Siremobil Iso-C 3D. With respect to image quality in cervical 3D scans, the Siremobil Iso-C 3D reached significantly higher scores in all categories. The Vision FD Vario 3D revealed less artifacts in lumbar 3D scans. Conclusions: The Siremobil Iso-C 3D provides high-quality 3D scans in slender spine regions (eg, cervical spine), whereas the Vision FD Vario 3D appears to have advantages in the lumbar spine. Further evolution and novel devices are needed to optimize image quality and handling.
引用
收藏
页码:276 / 284
页数:9
相关论文
共 19 条
[1]   Navigated minimally invasive thoracolumbar pedicle screw placement with flat panel 3-D imaging. A feasibility study [J].
Citak, Musa ;
Stubig, Timo ;
Kendoff, Daniel ;
Citak, Mustafa ;
O'Loughlin, Padhraig F. ;
Huefner, Tobias ;
Krettek, Christian .
TECHNOLOGY AND HEALTH CARE, 2010, 18 (02) :101-110
[2]   Iso-C/3-Dimensional Neuronavigation versus Conventional Fluoroscopy for Minimally Invasive Pedicle Screw Placement in Lumbar Fusion [J].
Fraser, J. ;
Gebhard, H. ;
Irie, D. ;
Parikh, K. ;
Haertl, R. .
MINIMALLY INVASIVE NEUROSURGERY, 2010, 53 (04) :184-190
[3]   Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques [J].
Gelalis, Ioannis D. ;
Paschos, Nikolaos K. ;
Pakos, Emilios E. ;
Politis, Angelos N. ;
Arnaoutoglou, Christina M. ;
Karageorgos, Athanasios C. ;
Ploumis, Avraam ;
Xenakis, Theodoros A. .
EUROPEAN SPINE JOURNAL, 2012, 21 (02) :247-255
[4]   Intraoperative three-dimensional navigation for pedicle screw placement [J].
Grützner, PA ;
Beutler, T ;
Wendl, K ;
von Recum, J ;
Wentzensen, A ;
Nolte, LP .
CHIRURG, 2004, 75 (10) :967-975
[5]   Intraoperative Iso-C C-arm navigation in cervical spinal surgery - Review of the first 52 cases [J].
Hott, JS ;
Papadopoulos, SM ;
Theodore, N ;
Dickman, CA ;
Sonntag, VKH .
SPINE, 2004, 29 (24) :2856-2860
[6]  
Klingler JH, 2014, J SPINAL DISORD TECH
[7]   Pedicle screw placement accuracy - A meta-analysis [J].
Kosmopoulos, Victor ;
Schizas, Constantin .
SPINE, 2007, 32 (03) :E111-E120
[8]   3D imaging with an isocentric mobile C-arm - Comparison of image quality with spiral CT [J].
Kotsianos, D ;
Wirth, S ;
Fischer, T ;
Euler, E ;
Rock, C ;
Linsenmaier, U ;
Pfeifer, KJ ;
Reiser, M .
EUROPEAN RADIOLOGY, 2004, 14 (09) :1590-1595
[9]   Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients [J].
Laine, T ;
Lund, T ;
Ylikoski, M ;
Lohikoski, J ;
Schlenzka, D .
EUROPEAN SPINE JOURNAL, 2000, 9 (03) :235-240
[10]   Comparison of the Percutaneous Screw Placement Precision of Isocentric C-arm 3-dimensional Fluoroscopy-navigated Pedicle Screw Implantation and Conventional Fluoroscopy Method With Minimally Invasive Surgery [J].
Nakashima, Hiroaki ;
Sato, Kouji ;
Ando, Toshihiro ;
Inoh, Hidefumi ;
Nakamura, Hiroshi .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (07) :468-472