Optimized radiofrequency lesions through local impedance guidance for effective CTI ablation in right atrial flutter

被引:1
作者
Ducceschi, Valentino [1 ,12 ]
Zingarini, Gianluca [2 ]
Nigro, Gerardo [3 ]
Brasca, Francesco Maria Angelo [4 ]
Malacrida, Maurizio [5 ]
Carbone, Angelo [6 ]
Lavalle, Carlo [7 ]
Maglia, Giampiero [8 ]
Infusino, Tommaso [9 ]
Aloia, Antonio [10 ]
Nicolis, Daniele [11 ]
Auricchio, Claudia [5 ]
Uccello, Ambra [12 ]
Notaristefano, Francesco [2 ]
Rago, Anna [3 ]
Botto, Giovanni Luca [4 ]
Esposito, Luca [12 ]
机构
[1] Pellegrini Hosp, Via Portamedina Alla Pignasecca 41, I-80135 Naples, Italy
[2] Santa Maria della Misericordia Hosp, Perugia, Italy
[3] Monaldi Hosp, Dept Cardiol, Naples, Italy
[4] Garbagnate Milanese Hosp, Civile Hosp, Rho & Salvini Hosp, ASST Rhodense, Milan, Italy
[5] Boston Sci, Milan, Italy
[6] Maria SS Addolorata Hosp, Eboli, Italy
[7] Umberto I Hosp, Rome, Italy
[8] Pugliese Ciaccio Hosp, Catanzaro, Italy
[9] St Anna Hosp, Catanzaro, Italy
[10] Presidio Osped Vallo della Lucania, Div Cardiol, Vallo Della Lucania, Italy
[11] Carlo Poma Hosp, Mantua, Italy
[12] Buon Consiglio Fatebenefratelli Hosp, Div Cardiol, Naples, Italy
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2022年 / 45卷 / 05期
关键词
catheter ablation; DirectSense (TM); local impedance; right atrial flutter; Rhythmia (TM) mapping system; supraventricular tachycardia; CAVOTRICUSPID ISTHMUS ABLATION; TISSUE CONTACT FORCE; CATHETER ABLATION; PREDICTORS; OUTCOMES; INDEX;
D O I
10.1111/pace.14482
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although radiofrequency (RF) catheter ablation of cavo-tricuspid isthmus (CTI) is an established treatment for typical right atrial flutter (RAFL), it remains to be established whether local tissue impedance (LI) is able to predict effective CTI ablation and what LI drop values during ablation should be used to judge a lesion as effective. We aimed to investigate the ability of LI to predict ablation efficacy in patients with RAFL. Methods: RF delivery was guided by the DirectSense (TM) algorithm. Successful single RF application was defined according to a defragmentation of atrial potentials (DAP), reduction of voltage (RedV) by at least 80% or changes on unipolar electrogram (UPC). The ablation endpoint was the creation of bidirectional conduction block (BDB) across the isthmus. Results: 392 point-by-point RF applications were analyzed in 48 consecutive RAFL patients. The mean baseline LI was 105.4 +/- 12 Omega prior to ablation and 92.0 +/- 11 Omega after ablation (p < 0.0001). According to validation criteria, absolute drops in impedance were larger at successful ablation sites than at ineffective ablation sites (DAP: 17.8 +/- 6 Omega vs. 8.7 +/- 4 Omega; RedV: 17.2 +/- 6 Omega vs. 7.8 +/- 5 Omega; UPC: 19.6 +/- 6 Omega vs. 10.1 +/- 5 Omega, all p < 0.0001). LI drop values significantly increased according to the number of criteria satisfied (ranging from 7.5 Omega to 19.9). BDB was obtained in all cases. No procedure-related adverse events were reported. Conclusions: A LI-guided approach to CTI ablation was safe and effective in treating RAFL. The magnitude of LI drop was associated with effective lesion formation and BDB and could be used as a marker of ablation efficacy.
引用
收藏
页码:612 / 618
页数:7
相关论文
共 28 条
[1]   Long term follow up of radiofrequency catheter ablation of atrial flutter:: clinical course and predictors of atrial fibrillation occurrence [J].
Bertaglia, E ;
Zoppo, F ;
Bonso, A ;
Proclemer, A ;
Verlato, R ;
Corò, L ;
Mantovan, R ;
D'Este, D ;
Zerbo, F ;
Pascotto, P .
HEART, 2004, 90 (01) :59-63
[2]   2019 ESC Guidelines for the management of patients with supraventricular tachycardia The Task Force for the management of patients with supraventricular tachycardia of the European Society of Cardiology (ESC): Developed in collaboration with the Association for European Paediatric and Congenital Cardiology (AEPC) [J].
Brugada, Josep ;
Katritsis, Demosthenes G. ;
Arbelo, Elena ;
Arribas, Fernando ;
Bax, Jeroen J. ;
Blomstrom-Lundqvist, Carina ;
Calkins, Hugh ;
Corrado, Domenico ;
Deftereos, Spyridon G. ;
Diller, Gerhard-Paul ;
Gomez-Doblas, Juan J. ;
Gorenek, Bulent ;
Grace, Andrew ;
Ho, Siew Yen ;
Kaski, Juan-Carlos ;
Kuck, Karl-Heinz ;
Lambiase, Pier David ;
Sacher, Frederic ;
Sarquella-Brugada, Georgia ;
Suwalski, Piotr ;
Zaza, Antonio .
EUROPEAN HEART JOURNAL, 2020, 41 (05) :655-720
[3]   Outcomes After Ablation for Typical Atrial Flutter (from the Loire Valley Atrial Fibrillation Project) [J].
Clementy, Nicolas ;
Desprets, Laurent ;
Pierre, Bertrand ;
Lallemand, Benedicte ;
Simeon, Edouard ;
Brunet-Bernard, Anne ;
Babuty, Dominique ;
Fauchier, Laurent .
AMERICAN JOURNAL OF CARDIOLOGY, 2014, 114 (09) :1361-1367
[4]   Local catheter impedance drop during pulmonary vein isolation predicts acute conduction block in patients with paroxysmal atrial fibrillation: initial results of the LOCALIZE clinical trial [J].
Das, Moloy ;
Luik, Armin ;
Shepherd, Ewen ;
Sulkin, Matthew ;
Laughner, Jacob ;
Oesterlein, Tobias ;
Duffy, Elizabeth ;
Meyer, Christian ;
Jais, Pierre ;
Duchateau, Josselin ;
Yue, Arthur ;
Ullah, Waqas ;
Ramos, Pablo ;
Garcia-Bolao, Ignacio .
EUROPACE, 2021, 23 (07) :1042-1051
[5]   New mapping tools to assess lesion in atrial fibrillation [J].
Garcia-Bolao, Ignacio ;
Ramos, Pablo ;
Ballesteros, Gabriel ;
Vives, Enrique .
EUROPACE, 2019, 21 :2-4
[6]   A randomized trial of contact force in atrial flutter ablation [J].
Giehm-Reese, Mikkel ;
Kronborg, Mads Brix ;
Lukac, Peter ;
Kristiansen, Steen Buus ;
Jensen, Henrik Kjaerulf ;
Gerdes, Christian ;
Kristensen, Jens ;
Nielsen, Jan Moller ;
Nielsen, Jens Cosedis .
EUROPACE, 2020, 22 (06) :947-955
[7]   Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter [J].
Gould, Paul A. ;
Booth, Cameron ;
Dauber, Kieran ;
Ng, Kevin ;
Claughton, Andrew ;
Kaye, Gerald C. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (12) :1429-1436
[8]   Relationship Between Catheter Contact Force and Radiofrequency Lesion Size and Incidence of Steam Pop in the Beating Canine Heart Electrogram Amplitude, Impedance, and Electrode Temperature Are Poor Predictors of Electrode-Tissue Contact Force and Lesion Size [J].
Ikeda, Atsushi ;
Nakagawa, Hiroshi ;
Lambert, Hendrik ;
Shah, Dipen C. ;
Fonck, Edouard ;
Yulzari, Aude ;
Sharma, Tushar ;
Pitha, Jan V. ;
Lazzara, Ralph ;
Jackman, Warren M. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (06) :1174-1180
[9]   The benefit of tissue contact monitoring with an electrical coupling index during ablation of typical atrial flutter-a prospective randomised control trial [J].
Jones, Michael A. ;
Webster, David ;
Wong, Kelvin C. K. ;
Hayes, Christopher ;
Qureshi, Norman ;
Rajappan, Kim ;
Bashir, Yaver ;
Betts, Timothy R. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 41 (03) :237-244
[10]   Clinical Anatomy of the Cavotricuspid Isthmus and Terminal Crest [J].
Klimek-Piotrowska, Wieslawa ;
Holda, Mateusz K. ;
Koziej, Mateusz ;
Holda, Jakub ;
Piatek, Katarzyna ;
Tyrak, Kamil ;
Bolechala, Filip .
PLOS ONE, 2016, 11 (09)