Amperometric inhibition biosensors based on horseradish peroxidase and gold sononanoparticles immobilized onto different electrodes for cyanide measurements

被引:50
作者
Attar, Aisha [1 ,2 ]
Cubillana-Aguilera, Laura [2 ]
Naranjo-Rodriguez, Ignacio [2 ]
Hidalgo-Hidalgo de Cisneros, Jose Luis [2 ]
Maria Palacios-Santander, Jose [2 ]
Amine, Aziz [1 ]
机构
[1] Univ Hassan II Mohammedia, Fac Sci & Tech, Mohammadia 20650, Morocco
[2] Univ Cadiz, Dept Quim Analit, Inst Univ Invest Microscopia Elect & Mat IMEYMAT, Fac Ciencias, Cadiz 11510, Spain
关键词
Cyanide; Enzyme biosensor; Horseradish peroxidase; Sonogel-carbon; Gold sononanoparticles; CARBON ELECTRODE; NANOPARTICLES; OXIDASE; DESIGN; SENSOR;
D O I
10.1016/j.bioelechem.2014.08.003
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
New biosensors based on inhibition for the detection of cyanide and the comparison of the analytical performances of nine enzyme biosensor designs by using three different electrodes: Sonogel-Carbon, glassy carbon and gold electrodes were discussed. Three different horseradish peroxidase immobilization procedures with and without gold sononanoparticles were studied. The amperometric measurements were performed at an applied potential of -0.15 V vs. Ag/AgCl in 50 mM sodium acetate buffer solution pH = 5.0. The apparent kinetic parameters (K-mapp, V-maxapp) of immobilized HRP were calculated in the absence of inhibitor (cyanide) by using caffeic acid, hydroquinone, and catechol as substrates. The presence of gold sononanoparticles enhanced the electron transfer reaction and improved the analytical performance of the biosensors. The HRP kinetic interactions reveal non-competitive binding of cyanide with an apparent inhibition constant (K-i) of 2.7 mu M and I-50 of 1.3 mu M. The determination of cyanide can be achieved in a dynamic range of 0.1-58.6 mu M with a detection limit of 0.03 mu M which is lower than those reported by previous studies. Hence this biosensing methodology can be used as a new promising approach for detecting cyanide. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 44 条
  • [1] Configurations used in the design of screen-printed enzymatic biosensors.: A review
    Albareda-Sirvent, M
    Merkoçi, A
    Alegret, S
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) : 153 - 163
  • [2] Enzyme inhibition-based biosensors for food safety and environmental monitoring
    Amine, A
    Mohammadi, H
    Bourais, I
    Palleschi, G
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) : 1405 - 1423
  • [3] CYANIDE DETERMINATION USING AN AMPEROMETRIC BIOSENSOR BASED ON CYTOCHROME-OXIDASE INHIBITION
    AMINE, A
    ALAFANDY, M
    KAUFFMANN, JM
    PEKLI, MN
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (17) : 2822 - 2827
  • [4] Analytical aspects of enzyme reversible inhibition
    Amine, Aziz
    El Harrad, Loubna
    Arduini, Fabiana
    Moscone, Danila
    Palleschi, Giuseppe
    [J]. TALANTA, 2014, 118 : 368 - 374
  • [5] ANZECC 2000 Guidelines, Australian and New Zealand Guidelines for Fresh and Marine Water Quality
  • [6] Impedance spectroscopy and conductometric biosensing for probing catalase reaction with cyanide as ligand and inhibitor
    Bouyahia, Naima
    Hamlaoui, Mohamed Larbi
    Hnaien, Mouna
    Lagarde, Florence
    Jaffrezic-Renault, Nicole
    [J]. BIOELECTROCHEMISTRY, 2011, 80 (02) : 155 - 161
  • [7] Modified electrode approaches for nitric oxide sensing
    Casero, E
    Losada, J
    Pariente, F
    Lorenzo, E
    [J]. TALANTA, 2003, 61 (01) : 61 - 70
  • [8] A novel amperometric phenol biosensor based on immobilized HRP on poly(glycidylmethacrylate)-grafted iron oxide nanoparticles for the determination of phenol derivatives
    Cevik, Emre
    Senel, Mehmet
    Baykal, Abdulhadi
    Abasiyanik, M. Fatih
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 396 - 405
  • [9] An amperometric biosensor based on acetylcholinesterase immobilized onto iron oxide nanoparticles/multi-walled carbon nanotubes modified gold electrode for measurement of organophosphorus insecticides
    Chauhan, Nidhi
    Pundir, Chandra Shekhar
    [J]. ANALYTICA CHIMICA ACTA, 2011, 701 (01) : 66 - 74
  • [10] A novel bienzyme glucose biosensor based on three-layer Au-Fe3O4@SiO2 magnetic nanocomposite
    Chen, Xiaojun
    Zhu, Jinwei
    Chen, Zixuan
    Xu, Chenbin
    Wang, Yan
    Yao, Cheng
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 159 (01): : 220 - 228