A Risk Assessment of Transmission Line Overload Based on MLSI/PSO

被引:0
|
作者
Izhak, R. [1 ]
Ali, A. [1 ]
Nazir, Muhammad S. [2 ]
Malik, Muhammad Z. [2 ]
机构
[1] Univ Malaysia Pahang, Fac Elect & Elect Engn, Kuantan, Malaysia
[2] Huaiyin Inst Technol, Coll Automat, Huaian 223003, Peoples R China
关键词
Transmission line; overload; and generation rescheduling; PROBABILISTIC LOAD-FLOW;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Aiming at the randomness of the output power of distributed generation, a method of transmission line overload risk assessment based on MLSI/PSO is proposed. Based on the traditional partial swarm optimization algorithm, the corresponding weights are selected according to the influence factors of each input quantity, and the calculation accuracy of the traditional point estimation method is improved to realize the overload risk assessment of transmission lines. The risk of transmission line overload in IEEE30 bus system with wind-solar complementary generation unit is evaluated. The analysis results show that the proposed method has the characteristics of low calculation cost and high prediction accuracy compared with traditional point estimation method.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [1] Overload Risk Assessment of Power Transmission Line Considering Dynamic Line Rating
    Ding Z.
    Yu K.
    Wang C.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (09): : 146 - 152
  • [2] PSO Based Generator Rescheduling For Relieving Transmission Overload
    Paul, Jasmy
    Joseph, Tibin
    Sreedharan, Sasidharan
    2013 IEEE INTERNATIONAL MULTI CONFERENCE ON AUTOMATION, COMPUTING, COMMUNICATION, CONTROL AND COMPRESSED SENSING (IMAC4S), 2013, : 409 - 414
  • [3] A Bayesian approach for short-term transmission line thermal overload risk assessment
    Zhang, J
    Pu, J
    McCalley, JD
    Stern, H
    Gallus, WA
    IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (03) : 770 - 778
  • [4] ASSESSMENT MODEL AND OPTIMIZATION CONTROL TO TRANSMISSION LINE OVERLOAD
    Zhang, Jian-Hua
    Fan, Luo
    Zheng, Jing-Jing
    Lin, Yue
    ENERGY, ENVIRONMENTAL & SUSTAINABLE ECOSYSTEM DEVELOPMENT, 2016,
  • [5] Transmission Line Overload Risk Assessment for Power Systems With Wind and Load-Power Generation Correlation
    Li, Xue
    Zhang, Xiong
    Wu, Lei
    Lu, Pan
    Zhang, Shaohua
    IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (03) : 1233 - 1242
  • [6] Fire risk assessment of transmission line based on BP neural network
    1600, Science and Engineering Research Support Society (08):
  • [7] Aging Risk Assessment based on Fuzzy logic for overhead transmission line
    Wang Yong
    Peng Chigang
    Liao Ruchao
    Zhou Huamin
    Zhang Ying
    Ke Tianjin
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 2606 - 2611
  • [9] Risk Control of Transmission Line Overload for Wind-Integrated Power Systems
    李雪
    路攀
    王春亮
    Journal of Donghua University(English Edition), 2014, 31 (02) : 124 - 127
  • [10] Risk assessment of the iced transmission line galloping based on fuzzy and cluster algorithms
    Zhang, Zhimeng
    Liu, Jie
    Jia, Boyan
    JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2022, 22 (05) : 1413 - 1432