Integral Sliding-Mode Direct Torque Control of Doubly-Fed Induction Generators Under Unbalanced Grid Voltage

被引:89
作者
Chen, Si Zhe [1 ]
Cheung, Norbert C. [2 ]
Wong, Ka Chung [2 ]
Wu, Jie [1 ]
机构
[1] S China Univ Technol, Coll Elect Power, Guangzhou 510640, Peoples R China
[2] Hong Kong Polytech Univ, Dept Elect Engn, Kowloon, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Direct torque control (DTC); doubly-fed induction generator (DFIG); integral sliding-mode control; unbalanced grid voltage; wind-energy generation; POWER-CONTROL; DFIG; SYSTEMS;
D O I
10.1109/TEC.2009.2036249
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An integral sliding-mode direct torque control (ISM-DTC) scheme with space-vector modulation for wind-energy conversion systems based on doubly-fed induction generators (DFIGs) under unbalanced grid voltage is proposed. The torque and power pulsations at twice the grid frequency caused by unbalanced grid voltage can be minimized by the proposed ISM-DTC scheme. Compared with existing control schemes of DFIGs under unbalanced grid voltage, the parametric uncertainties are included into the design procedure of sliding-mode controller, which guarantees the robustness of the controller. Because the torque and reactive power are directly controlled by the rotor voltage, the measurement, coordinate transformation, and symmetrical component extraction of rotor current are eliminated, which simplifies the structure of the controller. Simulation and hardware implementation results validate the effect and parametric robustness of the proposed ISM-DTC scheme.
引用
收藏
页码:356 / 368
页数:13
相关论文
共 17 条
[1]  
Albertos P., 2004, ADV TK CONT SIGN PRO
[2]   Control of a doubly fed induction wind generator under unbalanced grid voltage conditions [J].
Brekken, Ted K. A. ;
Mohan, Ned .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :129-135
[3]   Direct torque control of PWM inverter-fed AC motors - A survey [J].
Buja, GS ;
Kazmierkowski, MP .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2004, 51 (04) :744-757
[4]  
CHUNG SK, P 1995 IEEE IND EL C, P668
[5]   PULSEWIDTH MODULATION FOR ELECTRONIC POWER CONVERSION [J].
HOLTZ, J .
PROCEEDINGS OF THE IEEE, 1994, 82 (08) :1194-1214
[6]   Improved Control of DFIG Systems During Network Unbalance Using PI-R Current Regulators [J].
Hu, Jiabing ;
He, Yikang ;
Xu, Lie ;
Williams, Barry W. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) :439-451
[7]  
MULJADI E, P 1999 INT IND APPL, P1359
[8]   Energy-reliability optimization of wind energy conversion systems by sliding mode control [J].
Munteanu, Iulian ;
Bacha, Seddik ;
Bratcu, Antoneta Iuliana ;
Guiraud, Joel ;
Roye, Daniel .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (03) :975-985
[9]   Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation [J].
Pena, R ;
Clare, JC ;
Asher, GM .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1996, 143 (03) :231-241
[10]   Modeling and experimental verification of grid interaction of a DFIG wind turbine [J].
Petersson, A ;
Thiringer, T ;
Harnefors, L ;
Petru, T .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (04) :878-886