Calibration and Laboratory Testing of Computer Measuring System 8AE-PD Dedicated for Analysis of Acoustic Emission Signals Generated by Partial Discharges Within Oil Power Transformers

被引:9
作者
Witos, Franciszek [1 ]
Szerszen, Grzegorz [2 ]
Opilski, Zbigniew [1 ]
Setkiewicz, Maciej [1 ]
Olszewska, Aneta [1 ]
Duda, Dominik [3 ]
Mazniewski, Krzysztof [3 ]
Szadkowski, Marek [3 ]
机构
[1] Silesian Tech Univ, Fac Elect Engn, Dept Optoelect, Krzywoustego 2, PL-44100 Gliwice, Poland
[2] State Higher Vocat Sch Tarnow, Dept Elect & Telecommun, Mickiewicza 8, PL-33100 Tarnow, Poland
[3] Silesian Tech Univ, Fac Elect Engn, Inst Power Syst & Control, Krzywoustego 2, PL-44100 Gliwice, Poland
关键词
multichannel system; calibration; acoustic emission; partial discharge; power oil transformers; IDENTIFICATION; LOCATION;
D O I
10.1515/aoa-2017-0032
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the paper, there are presented a general description of the constructed measuring system 8AE-PD, the results of calibration of this system by the Hsu-Nielsen method as well as the testing of the measuring system during recording signals generated by Hsu-Nielsen sources in a steel plate and a modeled partial discharge (PD) source. There is also presented the methodology of investigations by the calibrated acoustic emission method. The results of analyses of PD signals coming from the modeled sources are given. In particular, there are described the properties of acoustic emission (AE) signals generated by the PDs as well as the dependencies of the peak-to-peak voltage U-mm, the RMS voltage U-rms and the descriptors of acronyms ADP and ADC on the apparent charge Q introduced by the modeled PD source. There are determined the limit values of the apparent charge Q introduced by the modeled PD source for which the recorded signal is identified as originating from the PDS.
引用
收藏
页码:297 / 311
页数:15
相关论文
共 20 条
[1]  
[Anonymous], 1347722010 EN
[2]   Identification of a specific type of PD from acoustic emission frequency spectra [J].
Boczar, T .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2001, 8 (04) :598-606
[3]  
Duda Dominik, 2014, Przeglad Elektrotechniczny, V90, P129, DOI 10.12915/pe.2014.10.33
[4]   Anusual Application of Partial Discharges to Diagnose of High Voltage Power Transformers [J].
Gacek, Z. ;
Szadkowski, M. ;
Malitowski, G. ;
Witos, F. ;
Olszewska, A. .
ACTA PHYSICA POLONICA A, 2011, 120 (04) :609-615
[5]  
HSU NN, 1981, MATER EVAL, V39, P60
[6]   Development of a fibre-optic sensor for partial discharges in oil-filled power transformers [J].
MacAlpine, M ;
Zhao, ZQ ;
Demokan, MS .
ELECTRIC POWER SYSTEMS RESEARCH, 2002, 63 (01) :27-36
[7]  
MALECKI I, 1993, ACUSTICA, V79, P112
[8]  
Meissner M., 1992, PRACE IPPT, V36
[9]   Location of Partial Discharge Sources and Analysis of Signals in Chosen Power Oil Transformers by Means of Acoustic Emission Method [J].
Olszewska, A. ;
Witos, F. .
ACTA PHYSICA POLONICA A, 2012, 122 (05) :921-926
[10]   Location and Identification of Acoustic Signals Recorded in Power Oil Transformers within the Band of 20-180 kHz [J].
Olszewska, A. ;
Witos, F. .
ACTA PHYSICA POLONICA A, 2011, 120 (04) :709-712