An in vitro evaluation of microtensile bond strengths of two adhesive bonding agents to residual dentine after caries removal using three excavation techniques

被引:40
作者
Banerjee, A. [1 ]
Kellow, S. [1 ]
Mannocci, F. [1 ]
Cook, R. J. [1 ]
Watson, T. F. [1 ]
机构
[1] KCL, Kings Coll London Dent Inst, London, England
关键词
Dentine; Caries; Excavation; Microtensile bond strength; Dentine bonding agent; Confocal microscopy; Composite; Silorane; Carisolv (TM) gel; Biosolv; SELF-ETCHING ADHESIVES; CARIOUS DENTIN; PRIMARY TEETH; AUTOFLUORESCENCE; SOUND; RESTORATIONS; INTERFACES; CRITERIA; LAYER;
D O I
10.1016/j.jdent.2010.03.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To assess amounts of residual dentine retained after using three excavation techniques; the microtensile bond strengths (mu TBS) to residual dentine, comparing etchrinse vs. self-etching adhesives. Methods: 42 carious molars were subdivided (N = 21) dependent upon adhesive/composite system (Adper Scotchbond 1XT and Filtek Supreme vs. Filtek Silorane adhesive and composite). Dividing into three (N = 7), dependent upon caries excavation technique employed (hand vs. chemo-mechanical: Carisolv (TM) gel vs. experimental enzymatic gel (SFC-V)), caries removal was assessed using visual/tactile criteria and in situ autofluorescence (AF) confocal fibre-optic micro-endoscopy (CFOME). Post-restoration/four-week hydrated storage, four 0.9 mm(2) beams per tooth underwent mu TBS testing/microscopic analysis of fractured surfaces. Three cavities from each excavation group were analysed using SEM. Results: SEM revealed surface roughness with smear layer occluding tubule orifices in hand-excavated samples and a reduced, variable smear layer for both chemo-mechanical systems. CFOME AF assessment indicated hand excavation left sound dentine, Carisolv (TM) left affected dentine and SFC-V slightly under-prepared clinically. Mean mu TBS values from etchrinse samples (27 MPa (SD 3.9), hand; 22 MPa (SD 5.1), Carisolv (TM); 26 MPa (SD 4.4), SFC-V) showed statistical differences between hand and Carisolv (TM) groups. Mean mu TBS data for self-etch samples (22 MPa (SD 3.3), hand; 27 MPa (SD 6.1), Carisolv (TM); 25 MPa (SD 4.7), SFC-V) showed significant differences between hand and Carisolv (TM), and hand vs. SFC-V. Failure loci distribution in etch-rinse samples was between dentine-adhesive, within adhesive and within composite whereas self-etch samples exhibited failure predominantly between adhesive and composite. Conclusions: Data indicated that all null hypotheses were disproved. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:480 / 489
页数:10
相关论文
共 33 条
[1]   Dentine caries excavation: a review of current clinical techniques [J].
Banerjee, A ;
Watson, TF ;
Kidd, EAM .
BRITISH DENTAL JOURNAL, 2000, 188 (09) :476-482
[2]   Autofluorescence and mineral content of carious dentine: Scanning optical and backscattered electron microscopic studies [J].
Banerjee, A ;
Boyde, A .
CARIES RESEARCH, 1998, 32 (03) :219-226
[3]   A confocal microscopic study relating the autofluorescence of carious dentine to its microhardness [J].
Banerjee, A ;
Sherriff, M ;
Kidd, EAM ;
Watson, TF .
BRITISH DENTAL JOURNAL, 1999, 187 (04) :206-210
[4]   In vitro evaluation of five alternative methods of carious dentine excavation [J].
Banerjee, A ;
Kidd, EAM ;
Watson, TF .
CARIES RESEARCH, 2000, 34 (02) :144-150
[5]  
Banerjee A, 2003, AM J DENT, V16, P228
[6]  
Banerjee A, 2000, Dent Update, V27, P272
[7]   Scanning electron microscopic observations of human dentine after mechanical caries excavation [J].
Banerjee, A ;
Kidd, EAM ;
Watson, TF .
JOURNAL OF DENTISTRY, 2000, 28 (03) :179-186
[8]  
BANERJEE A, EUROPEAN J IN PRESS
[9]  
BANERJEE A, PICKARDS MA IN PRESS
[10]   Microtensile bond strength of total-etch and self-etching adhesives to caries-affected dentine [J].
Ceballos, L ;
Camejo, DG ;
Fuentes, MV ;
Osorio, R ;
Toledano, M ;
Carvalho, RM ;
Pashley, DH .
JOURNAL OF DENTISTRY, 2003, 31 (07) :469-477