Effect of a Noise-Optimized Second-Generation Monoenergetic Algorithm on Image Noise and Conspicuity of Hypervascular Liver Tumors: An In Vitro and In Vivo Study

被引:46
作者
Marin, Daniele [1 ]
Ramirez-Giraldo, Juan Carlos [2 ]
Gupta, Sonia [1 ]
Fu, Wanyi [1 ]
Stinnett, Sandra S. [3 ]
Mileto, Achille [1 ]
Bellini, Davide [1 ]
Patel, Bhavik [1 ]
Samei, Ehsan [4 ]
Nelson, Rendon C. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Erwin Rd, Durham, NC 27710 USA
[2] Siemens Med Solut USA, Malvern, PA USA
[3] Duke Univ, Med Ctr, Ctr Eye, Erwin Rd, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, RAI Labs, Carl E Ravin Adv Imaging Labs, Erwin Rd, Durham, NC 27710 USA
关键词
dual-energy CT; hypervascular liver tumors; MDCT; monoenergetic reconstruction algorithm; noise; DUAL-ENERGY CT; RADIATION-DOSE REDUCTION; ITERATIVE RECONSTRUCTION; ABDOMINAL CT; SIZE; SELECTION; QUALITY;
D O I
10.2214/AJR.15.15512
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to investigate whether the reduction in noise using a second-generation monoenergetic algorithm can improve the conspicuity of hypervascular liver tumors on dual-energy CT (DECT) images of the liver. MATERIALS AND METHODS. An anthropomorphic liver phantom in three body sizes and iodine-containing inserts simulating hypervascular lesions was imaged with DECT and single-energy CT at various energy levels (80-140 kV). In addition, a retrospective clinical study was performed in 31 patients with 66 hypervascular liver tumors who underwent DECT during the late hepatic arterial phase. Datasets at energy levels ranging from 40 to 80 keV were reconstructed using first-and second-generation monoenergetic algorithms. Noise, tumor-to-liver contrast-to-noise ratio (CNR), and CNR with a noise constraint (CNRNC) set with a maximum noise increase of 50% were calculated and compared among the different reconstructed datasets. RESULTS. The maximum CNR for the second-generation monoenergetic algorithm, which was attained at 40 keV in both phantom and clinical datasets, was statistically significantly higher than the maximum CNR for the first-generation monoenergetic algorithm (p < 0.001) or single-energy CT acquisitions across a wide range of kilovoltage values. With the second-generation monoenergetic algorithm, the optimal CNRNC occurred at 55 keV, corresponding to lower energy levels compared with first-generation algorithm (predominantly at 70 keV). Patient body size did not substantially affect the selection of the optimal energy level to attain maximal CNR and CNRNC using the second-generation monoenergetic algorithm. CONCLUSION. A noise-optimized second-generation monoenergetic algorithm significantly improves the conspicuity of hypervascular liver tumors.
引用
收藏
页码:1222 / 1232
页数:11
相关论文
共 21 条
[1]  
[Anonymous], 2011, 204 AAPM
[2]  
[Anonymous], 2009, P SPIE
[3]   Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation [J].
Brady, Samuel L. ;
Kaufman, Robert A. .
RADIOLOGY, 2012, 265 (03) :832-840
[4]   Precision of Iodine Quantification in Hepatic CT: Effects of Iterative Reconstruction With Various Imaging Parameters [J].
Chen, Baiyu ;
Marin, Daniele ;
Richard, Samuel ;
Husarik, Daniela ;
Nelson, Rendon ;
Samei, Ehsan .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) :W475-W482
[5]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[6]   Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media [J].
Grant, Katharine L. ;
Flohr, Thomas G. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Thomas, Christoph ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2014, 49 (09) :586-592
[7]   Radiation Dose Reduction in Abdominal Computed Tomography During the Late Hepatic Arterial Phase Using a Model-Based Iterative Reconstruction Algorithm How Low Can We Go? [J].
Husarik, Daniela B. ;
Marin, Daniele ;
Samei, Ehsan ;
Richard, Samuel ;
Chen, Baiyu ;
Jaffe, Tracy A. ;
Bashir, Mustafa R. ;
Nelson, Rendon C. .
INVESTIGATIVE RADIOLOGY, 2012, 47 (08) :468-474
[8]   Application- and patient size-dependent optimization of x-ray spectra for CT [J].
Kalender, Willi A. ;
Deak, Paul ;
Kellermeier, Markus ;
van Straten, Marcel ;
Vollmar, Sabrina V. .
MEDICAL PHYSICS, 2009, 36 (03) :993-1007
[9]   Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT [J].
Leng, Shuai ;
Yu, Lifeng ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
RADIOLOGY, 2015, 276 (02) :562-570
[10]   Virtual Monochromatic Spectral Imaging with Fast Kilovoltage Switching: Improved Image Quality as Compared with That Obtained with Conventional 120-kVp CT [J].
Matsumoto, Kazuhiro ;
Jinzaki, Masahiro ;
Tanami, Yutaka ;
Ueno, Akihisa ;
Yamada, Minoru ;
Kuribayashi, Sachio .
RADIOLOGY, 2011, 259 (01) :257-262