Binding capacity differences for antibodies and Fc-fusion proteins on protein A chromatographic materials

被引:128
作者
Ghose, Sanchayita
Hubbard, Brian
Cramer, Steven M. [1 ]
机构
[1] Rensselaer Polytech Inst, Dept Chem & Biol Engn, Troy, NY USA
[2] Purificat Proc Dev, Amgen, WA USA
关键词
monoclonal antibodies; Fc-fusion proteins; Protein A chromatography; binding capacity; steric hindrance;
D O I
10.1002/bit.21044
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A range of studies were carried out to investigate the underlying reason for differences in dynamic binding capacities observed with various antibodies and Fc-fusion proteins during Protein A chromatography. Dynamic binding capacities were determined for these biomolecules using different protein A stationary phase materials. SEC was carried out to determine the relative sizes of the antibodies and fusion proteins: Pore diffusivities and static binding capacities were also determined on these Protein A resin materials. Trends in the dynamic binding capacities for these molecules did not correlate with differences in pore diffusion coefficients as might be expected for a mass transfer limited system. Instead, dynamic binding capacities were seen to follow the same trends as the static binding capacities and the apparent size of the molecules. Differences in static binding capacities were attributed to be due to differences in steric factor between the molecules. Solution binding stoichiometry studies were employed to estimate intro-Protein A steric effects while binding to the various domains within a Protein A ligand. In addition, steric hindrance was also found to exist between adjacent immobilized Protein A ligands on the chromatographic surface. The combination of intro and inter Protein A steric hindrances can explain differences in binding capacities observed between various antibody and Fc fusion proteins. The effect of Protein A ligand density on these supports was also examined and the results indicate that increasing Protein A ligand density leads to a situation of diminishing returns for binding capacity due to increased steric hindrance on the resin surface. The results presented in this paper show that steric hindrances can dominate over mass transfer effects in causing capacity variation between different molecules on the same stationary phase. This can lead to the development of more cost-efficient chromatographic stationary phases as well as provide information during the selection of Protein A media for preparative purification of monoclonal antibodies and Fc fusion proteins. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:768 / 779
页数:12
相关论文
共 32 条
[1]  
ARUFFO A, 1999, ANTIBODY FUSION PROT
[2]   STERIC MASS-ACTION ION-EXCHANGE - DISPLACEMENT PROFILES AND INDUCED SALT GRADIENTS [J].
BROOKS, CA ;
CRAMER, SM .
AICHE JOURNAL, 1992, 38 (12) :1969-1978
[3]   IMMUNOGLOBULIN-G - FUNCTIONAL SITES [J].
BURTON, DR .
MOLECULAR IMMUNOLOGY, 1985, 22 (03) :161-206
[4]  
Fahrner RL, 1999, BIOTECHNOL APPL BIOC, V30, P121
[5]   The optimal flow rate and column length for maximum production rate of protein A affinity chromatography [J].
Fahrner, RL ;
Iyer, HV ;
Blank, GS .
BIOPROCESS ENGINEERING, 1999, 21 (04) :287-292
[6]   Factorial screening of antibody purification processes using three chromatography steps without protein A [J].
Follman, DK ;
Farner, RL .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1024 (1-2) :79-85
[7]   PREDICTION OF ULTIMATE SEPARATION IN PARAMETRIC PUMPS [J].
FOO, SC ;
RICE, RG .
AICHE JOURNAL, 1975, 21 (06) :1149-1158
[8]  
Gagnon P.S., 1996, PURIFICATION TOOLS M, P155
[9]   Antibody variable region interactions with Protein A: Implications for the development of generic purification processes [J].
Ghose, S ;
Allen, M ;
Hubbard, B ;
Brooks, C ;
Cramer, SM .
BIOTECHNOLOGY AND BIOENGINEERING, 2005, 92 (06) :665-673
[10]   Use and optimization of a dual-flowrate loading strategy to maximize throughput in protein-A affinity chromatography [J].
Ghose, S ;
Nagrath, D ;
Hubbard, B ;
Brooks, C ;
Cramer, SM .
BIOTECHNOLOGY PROGRESS, 2004, 20 (03) :830-840