The Impact of Rapid On-Site Evaluation on the Quality and Diagnostic Value of Thyroid Nodule Fine-Needle Aspirations

被引:16
作者
Muri, Raphaela [1 ,2 ]
Trippel, Mafalda [3 ]
Borner, Urs [4 ]
Weidner, Sabine [5 ,6 ]
Trepp, Roman [1 ,7 ]
机构
[1] Univ Bern, Dept Diabet Endocrinol Nutr Med & Metab, Bern, Switzerland
[2] Univ Bern, Grad Sch Hlth Sci, Bern, Switzerland
[3] Univ Bern, Inst Pathol, Bern, Switzerland
[4] Univ Bern, Dept Otorhinolaryngol Head & Neck Surg, Bern, Switzerland
[5] Bern Univ Hosp, Dept Nucl Med, Inselspital, Bern, Switzerland
[6] Univ Bern, Bern, Switzerland
[7] Univ Bern, Bern Univ Hosp, Dept Diabet Endocrinol Med & Metab, Inselspital, CH-3010 Bern, Switzerland
关键词
Bethesda system; cytology; histology; rapid on-site evaluation; thyroid nodules; ultrasound-guided fine-needle aspiration; ADEQUACY ASSESSMENT; BETHESDA SYSTEM; ONSITE EVALUATION; CYTOPATHOLOGY; CYTOLOGY; FNA;
D O I
10.1089/thy.2021.0551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Ultrasound-guided fine-needle aspiration (FNA) is the preferred method to evaluate the dignity of thyroid nodules. Nevertheless, the often-reported high nondiagnostic rate burdens affected patients and the health care system. Rapid on-site evaluation (ROSE) constitutes an addition to the thyroid FNA procedure, with various studies showing its beneficial effect on the Bethesda I nondiagnostic rate. We aimed to assess whether ROSE may reduce the rate of Bethesda categories III and V. Additionally, we examined the influence of ROSE on specimen quality.Methods: We performed a retrospective cohort study, comparing Bethesda categorization and specimen quality in specimens subject to ROSE compared with those not subject to ROSE. We also evaluated aspects of specimen quality that differed according to the use of ROSE. We subcategorized Bethesda I into insufficient cellularity or artifacts, and Bethesda categories III and V into cellular without artifacts, sparsely cellular, or artifacts.Results: We evaluated 5030 thyroid FNAs. ROSE was performed in 1304 (25.9%) cases, and ROSE was not utilized for 3726 (74.1%) specimens. The rate of Bethesda I nondiagnostic and Bethesda III categories was reduced in specimens subject to ROSE (4.3%, 56/1304) compared with non-ROSE (39.9%, 1487/3726, p < 0.001). The rate of both benign Bethesda II and malignant Bethesda VI diagnoses was 91.6% (1194/1270) in ROSE specimens compared with 56.6% (1999/3530) in non-ROSE (p < 0.001). This was reflected by a significant improvement in diagnostic accuracy with ROSE (areas under the curve [AUC](non-ROSE) = 0.811, AUC(ROSE) = 0.895, p = 0.004). The overall rate of specimens flawed by sparse cellularity in Bethesda categories III and V was 0.1% (1/1304) in ROSE specimens compared with 1.2% (45/3726) in non-ROSE (p < 0.001). The overall artifact rate was 0.3% (4/1304) for ROSE specimens and 2.5% (92/3726) for non-ROSE (p < 0.001).Conclusions: ROSE significantly increased diagnostic accuracy by improving FNA specimens quantitatively and qualitatively. We suggest considering ROSE as standard of care for thyroid FNAs.
引用
收藏
页码:667 / 674
页数:8
相关论文
共 50 条
[21]   Fine-needle aspiration of thyroid and diagnostic accuracy [J].
Singh, Preeti ;
Rathi, Monika ;
Jaiswal, Vijay ;
Verma, Nidhi ;
Gupta, Priya ;
Karuna, Veer ;
Verma, Snehlata .
INTERNATIONAL JOURNAL OF HEALTH AND ALLIED SCIENCES, 2020, 9 (03) :223-228
[22]   Quality Improvement by Standardization of Procurement and Processing of Thyroid Fine-Needle Aspirates in the Absence of On-site Cytological Evaluation [J].
Sidiropoulos, Nikoletta ;
Dumont, Larry J. ;
Golding, Allan C. ;
Quinlisk, Francis L. ;
Gonzalez, Jorge L. ;
Padmanabhan, Vijayalakshmi .
THYROID, 2009, 19 (10) :1049-1052
[23]   Diagnostic value of thyroglobulin assay in cervical lymph node fine-needle aspirations for metastatic differentiated thyroid cancer [J].
Giovanella, Luca ;
Bongiovanni, Massimo ;
Trimboli, Pierpaolo .
CURRENT OPINION IN ONCOLOGY, 2013, 25 (01) :6-13
[24]   False negative rate of fine-needle aspiration in thyroid nodules: impact of nodule size and ultrasound pattern [J].
Ahn, Hye Shin ;
Na, Dong Gyu ;
Baek, Jung Hwan ;
Sung, Jin Yong ;
Kim, Ji-Hoon .
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2019, 41 (04) :967-973
[25]   Fine-Needle Aspiration Biopsy of Adrenal Gland Lesions: The Roles of Image Guidance, Rapid On-Site Evaluation and Additional Tissue Sampling [J].
Yu, Sanhong ;
Dolezal, Darin ;
Aslanian, Harry R. ;
Cai, Guoping .
CYTOPATHOLOGY, 2025, 36 (03) :228-235
[26]   Significance of Repeatedly Nondiagnostic Thyroid Fine-Needle Aspirations [J].
Renshaw, Andrew A. .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2011, 135 (05) :750-752
[27]   A New Cytology Staining Method: A Fast Approach for Rapid On-Site Evaluation on Thyroid Fine-Needle Aspiration Cytology [J].
Alves, Paula de Melo ;
Ferreira, Fernando ;
Oliveira, Telma ;
Alves, Daniela ;
Canberk, Sule ;
Schmitt, Fernando C. .
ACTA CYTOLOGICA, 2023, 67 (03) :289-294
[28]   Rapid On-Site Evaluation Increases Endoscopic Ultrasound-Guided Fine-Needle Aspiration Adequacy for Pancreatic Lesions [J].
Schmidt, Robert L. ;
Witt, Benjamin L. ;
Matynia, Anna P. ;
Barraza, Gonzalo ;
Layfield, Lester J. ;
Adler, Douglas G. .
DIGESTIVE DISEASES AND SCIENCES, 2013, 58 (03) :872-882
[29]   Impact of rapid on-site evaluation on diagnostic accuracy of EUS-guided fine-needle aspiration of solid pancreatic lesions: experience from a single center [J].
Irem Guvendir ;
Itir Ebru Zemheri ;
Kamil Ozdil .
BMC Gastroenterology, 22
[30]   Endoscopic ultrasound fine needle biopsy was not more cost-effective than fine-needle aspiration with rapid on-site evaluation in gastrointestinal lesions diagnosis [J].
Sbeit, Wisam ;
Khoury, Tawfik .
DIAGNOSTIC CYTOPATHOLOGY, 2021, 49 (08) :944-947