In vivo measurement of the three-dimensional motion of the sacroiliac joint

被引:20
|
作者
Wilke, HJ [1 ]
Fischer, K [1 ]
Jeanneret, B [1 ]
Claes, L [1 ]
Magerl, F [1 ]
机构
[1] Univ Ulm, Abt Unfallchirurg Forsch & Biomech, D-89081 Ulm, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE | 1997年 / 135卷 / 06期
关键词
sacroiliac joint; biomechanics; low-back pain; in vivo; three-dimensional motion;
D O I
10.1055/s-2008-1039744
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to quantify in vivo the three-dimensional motion patterns of the sacroiliac joint during passive manipulations as the opinions about the extent of motion of this joint are varied. 12 sacroiliac joints of 6 patients with clinically and radiologically normal joints were investigated. All patients were treated with an external fixator for diagnostic purposes of low back pain unrelated to this study. The motion of the sacroiliac joint was measured continuously with a three-dimensional goniometric system, which was mounted at the end of Schanz screws implanted in S1 and the ilium. All measurements showed relatively small rotation angles around the three main axis of the body between the ilium and the sacrum (< 2 degrees) and very small translations between the screw entry points into the bones (<1 mm). The maximum rotation angle in the sagittal plane was 1.3 degrees on the right joint and 1.6 degrees on the left joint for flexion plus extension. It is questionable whether this motion can be quantified during manual manipulation. Extension of the hip always produced the largest motion in the sacroiliac joint.
引用
收藏
页码:550 / 556
页数:7
相关论文
共 50 条
  • [21] Three-dimensional in vivo kinematics of the distal radioulnar joint in malunited distal radius fractures
    Moore, DC
    Hogan, KA
    Crisco, JJ
    Akelman, E
    DaSilva, MF
    Weiss, APC
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (02): : 233 - 242
  • [22] In vivo three-dimensional motion analysis of the forearm with radioulnar synostosis treated by the Kanaya procedure
    Oka, K
    Doi, K
    Suzuki, K
    Murase, T
    Goto, A
    Yoshikawa, H
    Sugamoto, K
    Moritomo, H
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (05) : 1028 - 1035
  • [23] Systematic review of sacroiliac joint motion and the effect of screw fixation
    Cardwell, Maxwell C.
    Meinerz, Carolyn M.
    Martin, Jill M.
    Beck, Chad J.
    Wang, Mei
    Schmeling, Gregory J.
    CLINICAL BIOMECHANICS, 2021, 85
  • [24] Sacroiliac joint motion in patients with degenerative lumbar spine disorders
    Nagamoto, Yukitaka
    Iwasaki, Motoki
    Sakaura, Hironobu
    Sugiura, Tsuyoshi
    Fujimori, Takahito
    Matsuo, Yohei
    Kashii, Masafumi
    Murase, Tsuyoshi
    Yoshikawa, Hideki
    Sugamoto, Kazuomi
    JOURNAL OF NEUROSURGERY-SPINE, 2015, 23 (02) : 209 - 216
  • [25] Assessment of Biomechanical Changes After Sacroiliac Joint Fusion by Application of the 3-Dimensional Motion Analysis Technique
    Jeong, Je Hoon
    Leasure, Jeremi M.
    Park, Jon
    WORLD NEUROSURGERY, 2018, 117 : E538 - E543
  • [26] Experimental characterization of motion resistance of the sacroiliac joint
    Toyohara, Ryota
    Hammer, Niels
    Ohashi, Toshiro
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2024, 35 (01) : 53 - 63
  • [27] Three-dimensional kinematics of the tarsal joint at the trot
    Lanovaz, J. L.
    Khumsap, S.
    Clayton, H. M.
    Stick, J. A.
    Brown, J.
    EQUINE VETERINARY JOURNAL, 2002, 34 : 308 - 313
  • [28] Dynamic evaluation of the contact characteristics and three-dimensional motion for the ankle joint with lateral ligament injuries
    Kawakami, K
    Omori, G
    Terashima, S
    Sakamoto, M
    Hara, T
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2001, 44 (04) : 1082 - 1088
  • [29] Effective shape of ball-and-socket prosthesis in restoring range of thumb motion for total thumb carpometacarpal joint arthroplasty: three-dimensional motion analysis
    Kurosawa, Akihiro
    Higuchi, Masahiro
    Tachiya, Hiroshi
    Tada, Kaoru
    Murai, Atsuro
    Nishi, Taiki
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [30] Reliability and measurement error of sagittal spinal motion parameters in 220 patients with chronic low back pain using a three-dimensional measurement device
    Mieritz, Rune M.
    Bronfort, Gert
    Jakobsen, Markus D.
    Aagaard, Per
    Hartvigsen, Jan
    SPINE JOURNAL, 2014, 14 (09) : 1835 - 1843