Glenoid component lucencies are associated with poorer patient-reported outcomes following anatomic shoulder arthroplasty

被引:24
|
作者
Schoch, Bradley S. [1 ]
Wright, Thomas W. [1 ]
Zuckerman, Joseph D. [2 ]
Bolch, Charlotte [3 ]
Flurin, Pierre-Henri [4 ]
Roche, Chris [3 ]
King, Joseph J. [1 ]
机构
[1] Univ Florida, Dept Orthopaed Surg & Rehabil, 3450 Hull Rd, Gainesville, FL 32611 USA
[2] NYU, New York, NY USA
[3] Exactech, Gainesville, FL USA
[4] Ctr Chirurg Orthoped & Sport, Bordeaux, France
关键词
Failure; glenoid loosening; loosening; outcomes; patient-reported outcomes; shoulder arthroplasty; RADIOGRAPHIC ASSESSMENT; COMPUTED-TOMOGRAPHY; HUMERAL COMPONENTS; REPLACEMENT; SURVIVAL; BONE;
D O I
10.1016/j.jse.2019.03.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: High rates of radiographic glenoid loosening following anatomic total shoulder arthroplasty (TSA) are documented at midterm follow-up. Small studies remain conflicted on the impact of lucent lines on clinical outcomes. This study assesses the impact of radiolucent lines on function and patient-reported outcomes (PROs) following TSA. Methods: We retrospectively evaluated 492 primary TSAs performed between February 2005 and April 2016. Radiographs were evaluated for glenoid loosening according to the Lazarus grade at a mean of 5.3 years (range, 2-12 years). Clinical outcome measures included range of motion and American Shoulder and Elbow Surgeons, Constant, University of California-Los Angeles, Simple Shoulder Test, and Shoulder Pain and Disability Index scores. Outcomes were compared between patients with and patients without glenoid lucent lines and in relation to lucency grade. Results: At most recent follow-up, 308 glenoids (63%) showed no radiolucent lines (group 0) and 184 demonstrated peri-glenoid lucencies (group 1). The groups were similar regarding age, sex, body mass index, comorbidities, and prior surgery. At follow-up, group 1 demonstrated significantly lower improvements in forward elevation (P = .02) and all PROs (P <= .005). Subgroup analysis by radiolucency grade showed that forward elevation diminished with increasing radiolucent score and exceeded the minimal clinically important difference (MCID) above grade 2 lucencies. A similar decline in PROs was observed with increasing lucency grade. These differences did not exceed the MOD below grade 5 lucencies. Discussion: Peri-implant glenoid lucencies following TSA are associated with lower forward elevation and PROs. Lucencies above grade 2 are associated with clinically important losses in overhead motion. However, differences below the MCID are maintained for PROs below grade 5 glenoid lucencies. (C) 2019 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:1956 / 1963
页数:8
相关论文
共 50 条
  • [1] The Glenoid Component in Anatomic Shoulder Arthroplasty
    Pinkas, Daphne
    Wiater, Brett
    Wiater, J. Michael
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2015, 23 (05) : 317 - 326
  • [2] Revisions for aseptic glenoid component loosening after anatomic shoulder arthroplasty
    Aibinder, William R.
    Schoch, Bradley
    Schleck, Cathy
    Sperling, John W.
    Cofield, Robert H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (03) : 443 - 449
  • [3] Failure of the Glenoid Component in Anatomic Total Shoulder Arthroplasty
    Papadonikolakis, Anastasios
    Neradilek, Moni Blazej
    Matsen, Frederick A., III
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (24) : 2205 - 2212
  • [4] Anatomic total shoulder arthroplasty with an inlay glenoid component: clinical outcomes and return to activity
    Cvetanovich, Gregory L.
    Naylor, Amanda J.
    O'Brien, Michael C.
    Waterman, Brian R.
    Garcia, Grant H.
    Nicholson, Gregory P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (06) : 1188 - 1196
  • [5] Prospective midterm results of a new convertible glenoid component in anatomic shoulder arthroplasty: a cohort study
    Magosch, Petra
    Lichtenberg, Sven
    Tauber, Mark
    Martetschlaeger, Frank
    Habermeyer, Peter
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (05) : 717 - 724
  • [6] Anatomic total shoulder arthroplasty with inlay glenoid component: A systematic review
    Berk, Alexander N.
    Cregar, William M.
    Rao, Allison J.
    Trofa, David P.
    Schiffern, Shadley C.
    Hamid, Nady
    Saltzman, Bryan M.
    SHOULDER & ELBOW, 2024, 16 (02) : 119 - 128
  • [7] The association between glenoid component design and revision risk in anatomic total shoulder arthroplasty
    Dillon, Mark T.
    Chan, Priscilla H.
    Prentice, Heather A.
    Burfeind, William E.
    Yian, Edward H.
    Singh, Anshuman
    Paxton, Elizabeth W.
    Navarro, Ronald A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (10) : 2089 - 2096
  • [8] Outcomes of Trabecular Metal-backed glenoid components in anatomic total shoulder arthroplasty
    Watson, Scott T.
    Gudger, Garland K., Jr.
    Long, Catherine D.
    Tokish, John M.
    Tolan, Stefan J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (03) : 493 - 498
  • [9] The effect of patient-reported metal allergies on the outcomes of shoulder arthroplasty
    Kennon, Justin C.
    Lee, Julia
    Songy, Chad
    Shukla, Dave
    Cofield, Robert H.
    Sanchez-Sotelo, Joaquin
    Sperling, John W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (02) : 296 - 301
  • [10] Responsiveness of patient-reported outcomes in shoulder arthroplasty: what are we actually measuring?
    Cronin, Kevin J.
    Magnuson, Justin A.
    Murphy, Meredith L.
    Unger, R. Zackary
    Jacobs, Cale A.
    Blake, Matthew H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (05) : 1174 - 1180