Biomechanical evaluation of anterior cervical spine stabilization

被引:79
|
作者
Grubb, MR [1 ]
Currier, BL [1 ]
Shih, JS [1 ]
Bonin, V [1 ]
Grabowski, JJ [1 ]
Chao, EYS [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Orthoped, Rochester, MN 55905 USA
关键词
biomechanics; cervical spine; spinal instrumentation;
D O I
10.1097/00007632-199804150-00009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An in vitro biomechanical study. Objectives. To simulate a severe compressive flexion injury for determination of the relative stability of different anterior instrumentation systems in a porcine model and to validate this model in human cadaveric specimen. Summary of Background Data. Anterior plate fixation is useful for high-grade mechanical insufficiency of the cervical spine and may prevent the need for a second procedure. Methods. The cervical spines of 45 porcine and 12 cadaveric specimens were subjected to nondestructive flexion, lateral bending, and torsional testing on a modified universal testing machine. A corpectomy was performed with release of the posterior ligamentous structures. The specimens were stabilized with one of three anterior plate constructs. The nondestructive testing was repeated to evaluate structural stability (stiffness and neutral zone). Finally, destructive testing examined failure moment, energy to failure, and mechanism of failure. Results. The instrumented specimens had flexural and lateral bending and torsional stiffness values that were similar to or greater than those of their paired intact specimens. The cervical spine locking plate had a significantly higher flexural stiffness ratio (plated:intact), torsional stiffness ratio, lower flexural neutral zone ratio, higher failure moment, and higher energy to failure than did the Caspar plate. Conclusions. The cervical spine locking plate is theoretically safer than the Caspar system because the posterior vertebral body cortex is not breached by the fixation screws, and the screws are less likely to back out anteriorly and irritate the esophagus. According to these results, the cervical spine locking plate system is biomechanically equivalent to and in some cases more stable than the Caspar system for fixation of a severe compressive flexion injury.
引用
收藏
页码:886 / 892
页数:7
相关论文
共 50 条
  • [11] Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems
    Wolfgang Lehmann
    Daniel Briem
    Michael Blauth
    Ulf Schmidt
    European Spine Journal, 2005, 14 : 243 - 249
  • [12] Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems
    Lehmann, W
    Briem, D
    Blauth, M
    Schmidt, U
    EUROPEAN SPINE JOURNAL, 2005, 14 (03) : 243 - 249
  • [13] Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase
    Wolfgang Lehmann
    Michael Blauth
    Daniel Briem
    Ulf Schmidt
    European Spine Journal, 2004, 13 : 69 - 75
  • [14] Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase
    Lehmann, W
    Blauth, M
    Briem, D
    Schmidt, U
    EUROPEAN SPINE JOURNAL, 2004, 13 (01) : 69 - 75
  • [15] Anterior instrumentation of the thoracolumbar spine - A biomechanical comparison
    Dick, JC
    Brodke, DS
    Zdeblick, TA
    Bartel, BD
    Kunz, DN
    Rapoff, AJ
    SPINE, 1997, 22 (07) : 744 - 750
  • [16] BIOMECHANICAL ASPECTS OF CERVICAL-SPINE INJURIES
    WALZ, F
    ORTHOPADE, 1994, 23 (04): : 262 - 267
  • [17] AN IN-VITRO BIOMECHANICAL COMPARISON OF THE OROSCO AND AO LOCKING PLATES FOR ANTERIOR CERVICAL-SPINE FIXATION
    SMITH, SA
    LINDSEY, RW
    DOHERTY, BJ
    ALEXANDER, J
    DICKSON, JH
    JOURNAL OF SPINAL DISORDERS, 1995, 8 (03): : 220 - 223
  • [18] Biomechanical study of anterior cervical corpectomy and step-cut grafting with bioabsorbable screws fixation in cadaveric cervical spine model
    Zhang, Jian
    He, Xijing
    Li, Haopeng
    Wang, Dong
    Zhao, Weidong
    Xu, Jiehua
    Lan, Binshang
    Xu, Siyue
    SPINE, 2006, 31 (19) : 2195 - 2201
  • [19] Biomechanical evaluation of a dynamic fusion cage design for cervical spine: A finite element study
    Liu, Jung-Tung
    Chen, Wen-Chuan
    Wei, Hung-Wen
    ADVANCES IN MECHANICAL ENGINEERING, 2017, 9 (05)
  • [20] An assessment of early tracheostomy after anterior cervical stabilization in patients with acute cervical spine trauma
    Berney, Susan
    Opdam, Helen
    Bellomo, Rinaldo
    Liew, Susan
    Skinner, Elizabeth
    Egi, Moritoki
    Denehy, Linda
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (03): : 749 - 753