Effect of fracture orientation on detection accuracy of vertical root fractures in non-endodontically treated teeth using cone beam computed tomography

被引:8
作者
Guo, Xiao-Long [1 ]
Li, Gang [1 ]
Yin, Shuang [1 ]
Ma, Ruo-Han [1 ]
Guo, Yu-Jiao [1 ]
Bornstein, Michael M. [2 ]
机构
[1] Peking Univ, Dept Oral & Maxillofacial Radiol, Sch & Hosp Stomatol, 22 Zhongguancun Nandajie, Beijing 100081, Peoples R China
[2] Univ Hong Kong, Oral & Maxillofacial Radiol, Appl Oral Sci, Fac Dent,Prince Philip Dent Hosp,Sai Ymg Pun, Hong Kong, Sar, Peoples R China
基金
中国国家自然科学基金;
关键词
Vertical root fracture; Cone beam computed tomography; Fracture orientation; Non-endodontically treated tooth; Diagnosis; DIAGNOSIS; RADIOGRAPHY; CT;
D O I
10.1007/s00784-019-02905-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study aimed to investigate the effect of fracture orientation on the detection accuracy of vertical root fractures (VRFs) in non-endodontically treated teeth using four different cone beam computed tomography (CBCT) units. Materials and methods Thirty eight out of 148 extracted human permanent teeth were chosen randomly, and VRFs were artificially induced to result in 20 mesiodistally and 18 buccolingually oriented root fractures. The fracture width was subsequently measured. All the teeth were scanned with four CBCT units. CBCT images were evaluated independently by two observers. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were calculated for each observer and fracture orientation. The AUC between the two fracture orientations was compared using Z test. Results The mean fracture width was 140 mu m (standard deviation 26.8 mu m). A statistically significant difference was found between the mesiodistal and buccolingual VRFs for the AUC from the CBCT unit 3D Accuitomo 170 (p = 0.02). There were no statistically significant differences between the mesiodistal and buccolingual VRFs for AUCs from the CBCT units NewTom VGi (p = 0.21), ProMax 3D Mid (p = 0.23), and i-CAT FLX (p = 0.21). Conclusion Fracture orientations of teeth with VRFs in non-endodontically treated teeth may play a role in the detection accuracy of CBCT images, but this effect seems to be dependent on the CBCT unit used.
引用
收藏
页码:4433 / 4439
页数:7
相关论文
共 31 条
[1]  
American Association of Endodontists, 2008, END COLL EXC CRACK T
[2]   A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth [J].
Brady, E. ;
Mannocci, F. ;
Brown, J. ;
Wilson, R. ;
Patel, S. .
INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (08) :735-746
[3]   Vertical root fracture in endodontically versus nonendodontically treated teeth - A survey of 315 cases in Chinese patients [J].
Chan, CP ;
Lin, CP ;
Tseng, SC ;
Jeng, JH .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 87 (04) :504-507
[4]   Cone beam computed tomography for the diagnosis of vertical root fractures: a systematic review of the literature and meta-analysis [J].
Corbella, Stefano ;
Del Fabbro, Massimo ;
Tamse, Aviad ;
Rosen, Eyal ;
Tsesis, Igor ;
Taschieri, Silvio .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2014, 118 (05) :593-602
[5]   Diagnosis of Mesiodistal Vertical Root Fractures in Teeth with Metal Posts: Influence of Applying Filters in Cone-beam Computed Tomography Images at Different Resolutions [J].
De Martin e Silva, Debora ;
Campos, Celso Neiva ;
Pires Carvalho, Antonio Carlos ;
Devito, Karina Lopes .
JOURNAL OF ENDODONTICS, 2018, 44 (03) :470-474
[6]   Dental cone beam CT image quality possibly reduced by patient movement [J].
Donaldson, K. ;
O'Connor, S. ;
Heath, N. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (02)
[7]   Accuracy of detecting vertical root fractures in non-root filled teeth using cone beam computed tomography: effect of voxel size and fracture width [J].
Guo, X. L. ;
Li, G. ;
Zheng, J. Q. ;
Ma, R. H. ;
Liu, F. C. ;
Yuan, F. S. ;
Lyu, P. J. ;
Guo, Y. J. ;
Yin, S. .
INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (06) :887-898
[8]   Comparison of Five Cone Beam Computed Tomography Systems for the Detection of Vertical Root Fractures [J].
Hassan, Bassam ;
Metska, Maria Elissavet ;
Ozok, Ahmet Rifat ;
van der Stelt, Paul ;
Wesselink, Paul Rudolf .
JOURNAL OF ENDODONTICS, 2010, 36 (01) :126-129
[9]   Detection of Vertical Root Fractures in Endodontically Treated Teeth by a Cone Beam Computed Tomography Scan [J].
Hassan, Bassam ;
Metska, Maria Elissavet ;
Ozok, Ahmet Rifat ;
van der Stelt, Paul ;
Wesselink, Paul Rudolf .
JOURNAL OF ENDODONTICS, 2009, 35 (05) :719-722
[10]   Vertical root fracture: Prevalence, etiology, and diagnosis [J].
Haueisen, Helga ;
Gaertner, Kathrin ;
Kaiser, Lea ;
Trohorsch, Dominik ;
Heidemann, Detlef .
QUINTESSENCE INTERNATIONAL, 2013, 44 (07) :467-474