Quantitation of mitral valve tenting in ischemic mitral regurgitation by transthoracic real-time three-dimensional echocardiography

被引:142
|
作者
Watanabe, N
Ogasawara, Y
Yamaura, Y
Kawamoto, T
Toyota, E
Akasaka, T
Yoshida, K
机构
[1] Kawasaki Med Sch, Dept Cardiol, Kurashiki, Okayama 7010192, Japan
[2] Kawasaki Med Sch, Dept Med Engn & Syst Cardiol, Kurashiki, Okayama 7010192, Japan
关键词
D O I
10.1016/j.jacc.2004.11.048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to investigate the geometric changes of the mitral leaflets and annulus, clarify the maximum tenting site of the leaflets, and quantify the valve tenting in ischemic mitral regurgitation (MR) using three-dimensional (3D) echocardiography. BACKGROUND Although the understanding of the mechanisms of ischemic MR has advanced recently, the geometric changes of the mitral leaflets and annulus have been assessed by two-dimensional echocardiography in the clinical setting, despite the unique configuration of the leaflets and annulus. METHODS Utilizing real-time 3D echocardiography, we obtained transthoracic volumetric images in 12 patients with ischemic MR presenting with global left ventricular dysfunction and in 10 controls. Original software was used to crop the 3D data into 18 radial planes, and we marked the mitral annulus and leaflets in each plane in mid-systole. The 3D images of the leaflets and annulus were reconstructed for the quantitative measurements. RESULTS In ischemic MR, the annulus flattened with apparent tenting of the leaflets. Maximum and mean tenting length were longer and tenting volume was larger in ischemic MR than control subjects (maximum tenting length: 9.8 +/- 2.0 mm vs. 3.1 +/- 1.2 mm, p < 0.0001, mean tenting length: 3.7 +/- 0.9 mm vs. 0.7 +/- 0.5 mm, p < 0.0001, tenting volume: 4.09 +/- 1.22 ml vs. 0.45 +/- 0.29 ml, p < 0.0001). The maximum tenting site was located in anterior leaflet in all patients. CONCLUSIONS We clearly demonstrated 3D geometric deformity of the mitral leaflets and annulus in ischemic MR using novel software for creating images by 3D echocardiography. This technique will be helpful in making a proper decision for the surgical strategy in each patient. (C) 2005 by the American College of Cardiology Foundation.
引用
收藏
页码:763 / 769
页数:7
相关论文
共 50 条
  • [1] Quantification and localization of mitral valve tenting in ischemic mitral.2 regurgitation using real-time three-dimensional echocardiography
    Ryan, Liam
    Jackson, Benjamin
    Parish, Landi
    Sakamoto, Hiroaki
    Plappert, Theodore
    Sutton, Martin St. John
    Gorman, Joseph, III
    Gorman, Robert
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 31 (05) : 839 - 844
  • [2] Geometric differences of the mitral valve tenting between anterior and inferior myocardial infarction with significant ischemic mitral regurgitation: Quantitation by novel software system with transthoracic real-time three-dimensional echocardiography
    Watanabe, Nozomi
    Ogasawara, Yasuo
    Yamaura, Yasuko
    Yamamoto, Katsunori
    Wada, Nozomi
    Kawamoto, Takahiro
    Toyota, Eiji
    Akasaka, Takashi
    Yoshida, Kiyoshi
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (01) : 71 - 75
  • [3] Value of mitral valve tenting volume determined by real-time three-dimensional echocardiography in patients with functional mitral regurgitation
    Song, Jong-Min
    Fukuda, Shota
    Kihara, Takashi
    Shin, Mi-Seung
    Garcia, Mario J.
    Thomas, James D.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (08): : 1088 - 1093
  • [4] Real-time three-dimensional echocardiography in ischemic mitral regurgitation
    Jackson, BM
    Parish, LM
    Gorman, RC
    Gorman, JH
    CIRCULATION, 2004, 110 (17) : 673 - 673
  • [5] Real-time three-dimensional echocardiography in ischemic mitral regurgitation
    Jackson, BM
    Parish, LM
    Gorman, RC
    Gorman, JH
    JOURNAL OF CARDIAC FAILURE, 2005, 11 (06) : S132 - S132
  • [6] Live/real-time three-dimensional transthoracic assessment of mitral regurgitation and mitral valve prolapse
    Miller, Andrew P.
    Nanda, Navin C.
    CARDIOLOGY CLINICS, 2007, 25 (02) : 319 - +
  • [7] Three-dimensional quantitation of mitral valve coaptation by a novel software system with transthoracic real-time three-dimensional echocardiography
    Tsukiji, Miwako
    Watanabe, Nozomi
    Yamaura, Yasuko
    Okahashi, Noriko
    Obase, Kikuko
    Neishi, Yoji
    Toyota, Eiji
    Kawamoto, Takahiro
    Okura, Hiroyuki
    Ogasawara, Yasuo
    Yoshida, Kiyoshi
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (01) : 43 - 46
  • [8] Automated quantification of mitral valve tenting volume in functional mitral regurgitation by three-dimensional echocardiography
    Huebscher, Anne
    Schwerg, Marius
    Hoffmann, Saskia
    Baldenhofer, Gerd
    Heupel, Christian
    Jasaityte, Ruta
    Kruck, Sebastian
    Stangl, Karl
    Dreger, Henryk
    Knebel, Fabian
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (07): : 1043 - 1048
  • [9] Mitral annulus flattens in patients with ischemic mitral regurgitation: Transthoracic real-time three-dimensional echocardiographic study
    Watanabe, N
    Akasaka, T
    Yamaura, Y
    Ogasawara, Y
    Wada, N
    Neishi, Y
    Koyama, Y
    Yoshida, K
    CIRCULATION, 2004, 110 (17) : 588 - 588
  • [10] Real-time three-dimensional dobutamine stress echocardiography for ischemic mitral regurgitation evaluation
    Liu Jiani
    Bai Wenjuan
    Chen, Xiongming
    Hong, Tang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C129 - C129