A simple simultaneous geometric and intensity correction method for echo-planar imaging by EPI-based phase modulation

被引:19
作者
Chiou, JY [1 ]
Ahn, CB
Muftuler, LT
Nalcioglu, O
机构
[1] Univ Calif Irvine, Dept Elect & Comp Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Coll Med, John Tu & Thomas Yuen Ctr Funct Oncoimagin, Irvine, CA 92697 USA
[3] Kwangwoon Univ, Dept Elect Engn, Seoul 139701, South Korea
关键词
echo planar imaging (EPI); field inhomogeneity; geometric distortions; nonuniform intensity;
D O I
10.1109/TMI.2002.808362
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A technique, based on Echo planar imaging (EPI)-based phase modulation factor maps, is described for correction of EPI distortions resulting from field inhomogeneity. In this paper, a phase modulation factor was employed to remove the distortions. The phase modulation factor was obtained experimentally by collecting EPI images with a spin-echo (TE) spacing. DeltaTE, equal to the inter-echo time interval, T-i. Then, the distortions resulting from the field inhomogeneity were removed by modulating the k-space data with the phase modulation factor. One of the advantages of this method is that it requires only a few extra scans to collect the information on field inhomogeneity. The proposed method does not require a phase unwrapping procedure for field inhomogeneity correction and, hence, is easier to implement, compared to other techniques. In addition, it corrects geometric distortion as well as intensity distortions simultaneously, which is robust to external noise or estimation error in severely distorted images. In this work, we also compared the proposed technique with others including, a) interpolation method with EPI-based displacement maps, and b) modulation method with phase modulation factor maps generated from spin-echo images. The results suggest the proposed technique is superior in correcting severely distorted images.
引用
收藏
页码:200 / 205
页数:6
相关论文
共 17 条
[1]   IMAGE-RECONSTRUCTION FOR ECHO PLANAR IMAGING WITH NONEQUIDISTANT KAPPA-SPACE SAMPLING [J].
BRUDER, H ;
FISCHER, H ;
REINFELDER, HE ;
SCHMITT, F .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :311-323
[2]   Ghost artifact reduction for echo planar imaging using image phase correction [J].
Buonocore, MH ;
Gao, LS .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :89-100
[3]  
Chen NK, 1999, MAGNET RESON MED, V41, P1206, DOI 10.1002/(SICI)1522-2594(199906)41:6<1206::AID-MRM17>3.0.CO
[4]  
2-L
[5]   Artifact reduction in EPI with phase-encoded reference scan [J].
Hu, XP ;
Le, TH .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) :166-171
[6]   CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS [J].
JEZZARD, P ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :65-73
[7]   Simulated phase evolution rewinding (SPHERE): A technique for reducing B-0 inhomogeneity effects in MR images [J].
Kadah, YM ;
Hu, XP .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :615-627
[8]   A model-based method for phase unwrapping [J].
Liang, ZP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (06) :893-897
[9]  
Luk-Pat GT, 2001, MAGNET RESON MED, V45, P269, DOI 10.1002/1522-2594(200102)45:2<269::AID-MRM1036>3.0.CO
[10]  
2-5