Awareness of indications for device therapy among a broad range of physicians: a survey study

被引:19
作者
Hubinette, Clara [1 ,2 ]
Lund, Lars H. [1 ,2 ]
Gadler, Fredrik [1 ,2 ]
Stahlberg, Marcus [1 ,2 ]
机构
[1] Karolinska Inst, Dept Med, S-17177 Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Cardiol, S-17176 Stockholm, Sweden
来源
EUROPACE | 2014年 / 16卷 / 11期
关键词
Heart failure; Device therapy; Cardiac resynchronization therapy; Implantable cardioverter-defibrillator; Referring physicians; CARDIAC-RESYNCHRONIZATION THERAPY; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; CHRONIC HEART-FAILURE; NATIONAL-SURVEY; PROPHYLACTIC IMPLANTATION; MYOCARDIAL-INFARCTION; PRIMARY PREVENTION; GUIDELINES; KNOWLEDGE; ATTITUDES;
D O I
10.1093/europace/eut416
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Cardiac resynchronization therapy (CRT) and primary prophylactic implantable cardioverter-defibrillators (ICDs) are underutilized in heart failure (HF). This may originate from an unawareness of device benefits and indications among physicians responsible for HF care and referral. We aimed to describe the awareness of indications for device therapy in a generalized sample of Swedish physicians. Methods and results A randomly selected sample of Swedish physicians specializing in cardiology, internal medicine, and family medicine and interns (5% of eligible physicians, n = 519) was invited to fill in a 23-item survey, testing their awareness of indications for device therapy and, as comparison, pharmacological therapy. Acceptable awareness (AA) of CRT indication was prede-fined as recognizing that a left bundle branch block on ECG warrants further evaluation for CRT. Acceptable awareness of ICD indication was prede-fined as recognizing that ejection fraction <= 35% alone, without a history of ventricular tachycardia, is sufficient to warrant a primary prophylactic ICD. The response rate was 37% (n = 168). Overall, 32% met AA of CRT indication, and significantly less (15%) met AA of ICD indication. Specialist certification in cardiology was the only significant predictor for AA [odds ratio (95% confidence interval): 37 (10-138)]. However, even among cardiologists, awareness of ICD indications was low (61% with AA). Guideline-recommended indications for pharmacological therapy were conceived significantly better (P = 0.02) than device therapy [median (interquartile range) of correct answers: 50% (33-50) compared with 36% (14-57)]. Conclusions The study identified an important and substantial awareness gap in the medical community that may explain some of the previously reported low referral rates and utilization of device therapy in HF.
引用
收藏
页码:1580 / 1586
页数:7
相关论文
共 26 条
[1]   Response rates to mail surveys published in medical journals [J].
Asch, DA ;
Jedrziewski, MK ;
Christakis, NA .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1997, 50 (10) :1129-1136
[2]   Is heart failure guideline adherence being underestimated? The impact of therapeutic contraindications [J].
Atwater, Brett D. ;
Dai, David ;
Allen-Lapointe, Nancy M. ;
Al-Khatib, Sana M. ;
Zimmer, Louise O. ;
Sanders, Gillian D. ;
Peterson, Eric D. .
AMERICAN HEART JOURNAL, 2012, 164 (05) :750-U153
[3]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[4]   Low Referral Rate for Prophylactic Implantation of Cardioverter-Defibrillators in a Tertiary Care Medical Center [J].
Bradfield, Jason ;
Warner, Alberta ;
Bersohn, Malcolm M. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 :S194-S197
[5]   2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy [J].
Brignole, Michele ;
Auricchio, Angelo ;
Baron-Esquivias, Gonzalo ;
Bordachar, Pierre ;
Boriani, Giuseppe ;
Breithardt, Ole-A ;
Cleland, John ;
Deharo, Jean-Claude ;
Delgado, Victoria ;
Elliott, Perry M. ;
Gorenek, Bulent ;
Israel, Carsten W. ;
Leclercq, Christophe ;
Linde, Cecilia ;
Mont, Llus ;
Padeletti, Luigi ;
Sutton, Richard ;
Vardas, Panos E. ;
Zamorano, Jose Luis ;
Achenbach, Stephan ;
Baumgartner, Helmut ;
Bax, Jeroen J. ;
Bueno, Hctor ;
Dean, Veronica ;
Deaton, Christi ;
Erol, Cetin ;
Fagard, Robert ;
Ferrari, Roberto ;
Hasdai, David ;
Hoes, Arno W. ;
Kirchhof, Paulus ;
Knuuti, Juhani ;
Kolh, Philippe ;
Lancellotti, Patrizio ;
Linhart, Ales ;
Nihoyannopoulos, Petros ;
Piepoli, Massimo F. ;
Ponikowski, Piotr ;
Sirnes, Per Anton ;
Tamargo, Juan Luis ;
Tendera, Michal ;
Torbicki, Adam ;
Wijns, William ;
Windecker, Stephan ;
Kirchhof, Paulus ;
Blomstrom-Lundqvist, Carina ;
Badano, Luigi P. ;
Aliyev, Farid ;
Bnsch, Dietmar ;
Baumgartner, Helmut .
EUROPACE, 2013, 15 (08) :1070-1118
[6]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[7]   European utilization of the implantable defibrillator: has 10 years changed the 'enigma'? [J].
Camm, A. John ;
Nisam, Seah .
EUROPACE, 2010, 12 (08) :1063-1069
[8]   Referring physicians' discordance with the primary prevention implantable cardioverter-defibrillator guidelines: A national survey [J].
Castellanos, Jorge M. ;
Smith, Lisa M. ;
Varosy, Paul D. ;
Dehlendorf, Christine ;
Marcus, Gregory M. .
HEART RHYTHM, 2012, 9 (06) :874-881
[9]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[10]   Cardiac resynchronization therapy utilization for heart failure: Findings from IMPROVE HF [J].
Curtis, Anne B. ;
Yancy, Clyde W. ;
Albert, Nancy M. ;
Stough, Wendy Gattis ;
Gheorghiade, Mihai ;
Heywood, J. Thomas ;
McBride, Mark L. ;
Mehra, Mandeep R. ;
O'Connor, Christopher M. ;
Reynolds, Dwight ;
Walsh, Mary Norine ;
Fonarow, Gregg C. .
AMERICAN HEART JOURNAL, 2009, 158 (06) :956-964