Awareness of indications for device therapy among a broad range of physicians: a survey study

被引:18
作者
Hubinette, Clara [1 ,2 ]
Lund, Lars H. [1 ,2 ]
Gadler, Fredrik [1 ,2 ]
Stahlberg, Marcus [1 ,2 ]
机构
[1] Karolinska Inst, Dept Med, S-17177 Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Cardiol, S-17176 Stockholm, Sweden
来源
EUROPACE | 2014年 / 16卷 / 11期
关键词
Heart failure; Device therapy; Cardiac resynchronization therapy; Implantable cardioverter-defibrillator; Referring physicians; CARDIAC-RESYNCHRONIZATION THERAPY; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; CHRONIC HEART-FAILURE; NATIONAL-SURVEY; PROPHYLACTIC IMPLANTATION; MYOCARDIAL-INFARCTION; PRIMARY PREVENTION; GUIDELINES; KNOWLEDGE; ATTITUDES;
D O I
10.1093/europace/eut416
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Cardiac resynchronization therapy (CRT) and primary prophylactic implantable cardioverter-defibrillators (ICDs) are underutilized in heart failure (HF). This may originate from an unawareness of device benefits and indications among physicians responsible for HF care and referral. We aimed to describe the awareness of indications for device therapy in a generalized sample of Swedish physicians. Methods and results A randomly selected sample of Swedish physicians specializing in cardiology, internal medicine, and family medicine and interns (5% of eligible physicians, n = 519) was invited to fill in a 23-item survey, testing their awareness of indications for device therapy and, as comparison, pharmacological therapy. Acceptable awareness (AA) of CRT indication was prede-fined as recognizing that a left bundle branch block on ECG warrants further evaluation for CRT. Acceptable awareness of ICD indication was prede-fined as recognizing that ejection fraction <= 35% alone, without a history of ventricular tachycardia, is sufficient to warrant a primary prophylactic ICD. The response rate was 37% (n = 168). Overall, 32% met AA of CRT indication, and significantly less (15%) met AA of ICD indication. Specialist certification in cardiology was the only significant predictor for AA [odds ratio (95% confidence interval): 37 (10-138)]. However, even among cardiologists, awareness of ICD indications was low (61% with AA). Guideline-recommended indications for pharmacological therapy were conceived significantly better (P = 0.02) than device therapy [median (interquartile range) of correct answers: 50% (33-50) compared with 36% (14-57)]. Conclusions The study identified an important and substantial awareness gap in the medical community that may explain some of the previously reported low referral rates and utilization of device therapy in HF.
引用
收藏
页码:1580 / 1586
页数:7
相关论文
共 26 条
  • [1] Response rates to mail surveys published in medical journals
    Asch, DA
    Jedrziewski, MK
    Christakis, NA
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 1997, 50 (10) : 1129 - 1136
  • [2] Is heart failure guideline adherence being underestimated? The impact of therapeutic contraindications
    Atwater, Brett D.
    Dai, David
    Allen-Lapointe, Nancy M.
    Al-Khatib, Sana M.
    Zimmer, Louise O.
    Sanders, Gillian D.
    Peterson, Eric D.
    [J]. AMERICAN HEART JOURNAL, 2012, 164 (05) : 750 - U153
  • [3] Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    Bardy, GH
    Lee, KL
    Mark, DB
    Poole, JE
    Packer, DL
    Boineau, R
    Domanski, M
    Troutman, C
    Anderson, J
    Johnson, G
    McNulty, SE
    Clapp-Channing, N
    Davidson-Ray, LD
    Fraulo, ES
    Fishbein, DP
    Luceri, RM
    Ip, JH
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) : 225 - 237
  • [4] Low Referral Rate for Prophylactic Implantation of Cardioverter-Defibrillators in a Tertiary Care Medical Center
    Bradfield, Jason
    Warner, Alberta
    Bersohn, Malcolm M.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 : S194 - S197
  • [5] 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
    Brignole, Michele
    Auricchio, Angelo
    Baron-Esquivias, Gonzalo
    Bordachar, Pierre
    Boriani, Giuseppe
    Breithardt, Ole-A
    Cleland, John
    Deharo, Jean-Claude
    Delgado, Victoria
    Elliott, Perry M.
    Gorenek, Bulent
    Israel, Carsten W.
    Leclercq, Christophe
    Linde, Cecilia
    Mont, Llus
    Padeletti, Luigi
    Sutton, Richard
    Vardas, Panos E.
    Zamorano, Jose Luis
    Achenbach, Stephan
    Baumgartner, Helmut
    Bax, Jeroen J.
    Bueno, Hctor
    Dean, Veronica
    Deaton, Christi
    Erol, Cetin
    Fagard, Robert
    Ferrari, Roberto
    Hasdai, David
    Hoes, Arno W.
    Kirchhof, Paulus
    Knuuti, Juhani
    Kolh, Philippe
    Lancellotti, Patrizio
    Linhart, Ales
    Nihoyannopoulos, Petros
    Piepoli, Massimo F.
    Ponikowski, Piotr
    Sirnes, Per Anton
    Tamargo, Juan Luis
    Tendera, Michal
    Torbicki, Adam
    Wijns, William
    Windecker, Stephan
    Kirchhof, Paulus
    Blomstrom-Lundqvist, Carina
    Badano, Luigi P.
    Aliyev, Farid
    Bnsch, Dietmar
    Baumgartner, Helmut
    [J]. EUROPACE, 2013, 15 (08): : 1070 - 1118
  • [6] Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure
    Bristow, MR
    Saxon, LA
    Boehmer, J
    Krueger, S
    Kass, DA
    De Marco, T
    Carson, P
    DiCarlo, L
    DeMets, D
    White, BG
    DeVries, DW
    Feldman, AM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) : 2140 - 2150
  • [7] European utilization of the implantable defibrillator: has 10 years changed the 'enigma'?
    Camm, A. John
    Nisam, Seah
    [J]. EUROPACE, 2010, 12 (08): : 1063 - 1069
  • [8] Referring physicians' discordance with the primary prevention implantable cardioverter-defibrillator guidelines: A national survey
    Castellanos, Jorge M.
    Smith, Lisa M.
    Varosy, Paul D.
    Dehlendorf, Christine
    Marcus, Gregory M.
    [J]. HEART RHYTHM, 2012, 9 (06) : 874 - 881
  • [9] The effect of cardiac resynchronization on morbidity and mortality in heart failure
    Cleland, JGF
    Daubert, J
    Erdmann, E
    Freemantle, N
    Gras, D
    Kappenberger, L
    Tavazzi, L
    Cleland, JGF
    Daubert, JC
    Erdmann, E
    Gras, D
    Kappenberger, L
    Klein, W
    Tavazzi, L
    Poole-Wilson, PA
    Rydén, L
    Wedel, H
    Wellens, HJJ
    Uretsky, B
    Thygesen, K
    Böcker, D
    Marijianowski, MMH
    Freemantle, N
    Calvert, MJ
    Christ, G
    Fruhwald, F
    Hofmann, R
    Krypta, A
    Leisch, F
    Pacher, R
    Rauscha, F
    Tavernier, R
    Thomsen, PEB
    Boesgaard, S
    Eiskjær, H
    Esperen, GT
    Haarbo, J
    Hagemann, A
    Korup, E
    Moller, M
    Mortensen, P
    Sogaard, P
    Vesterlund, T
    Huikuri, H
    Niemelä, KI
    Toivonen, L
    Bauer, F
    Cohen-Solal, A
    Crocq, C
    Djiane, P
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) : 1539 - 1549
  • [10] Cardiac resynchronization therapy utilization for heart failure: Findings from IMPROVE HF
    Curtis, Anne B.
    Yancy, Clyde W.
    Albert, Nancy M.
    Stough, Wendy Gattis
    Gheorghiade, Mihai
    Heywood, J. Thomas
    McBride, Mark L.
    Mehra, Mandeep R.
    O'Connor, Christopher M.
    Reynolds, Dwight
    Walsh, Mary Norine
    Fonarow, Gregg C.
    [J]. AMERICAN HEART JOURNAL, 2009, 158 (06) : 956 - 964