Relationship between the pressure and diameter of the carotid artery in humans

被引:140
作者
Sugawara, M [1 ]
Niki, K [1 ]
Furuhata, H [1 ]
Ohnishi, S [1 ]
Suzuki, S [1 ]
机构
[1] Tokyo Womens Med Coll, Sch Med, Dept Cardiovasc Sci, Shinjuku Ku, Tokyo 162, Japan
关键词
carotid artery; pressure; diameter; echo tracking; catheter-tipped micromanometer;
D O I
10.1007/PL00007261
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to examine the assumption of similarity between pressure and diameter-change waveforms in humans. We measured carotid arterial pressure and diameter change, simultaneously, in six patients with heart disease. In all patients, the carotid arterial pressure-diameter relationship could, in practice, be regarded as being linear.
引用
收藏
页码:49 / 51
页数:3
相关论文
共 2 条
[1]   A noninvasive method of measuring wave intensity, a new hemodynamic index: application to the carotid artery in patients with mitral regurgitation before and after surgery [J].
Niki, K ;
Sugawara, M ;
Uchida, K ;
Tanaka, R ;
Tanimoto, K ;
Imamura, H ;
Sakomura, Y ;
Ishizuka, N ;
Koyanagi, H ;
Kasanuki, H .
HEART AND VESSELS, 1999, 14 (06) :263-271
[2]   Noninvasive measurement of aortic pressure waveform by ultrasound [J].
Watanabe, H ;
Kawai, M ;
Sibata, T ;
Hara, M ;
Furuhata, H ;
Mochizuki, S .
HEART AND VESSELS, 1998, 13 (02) :79-86