Solar-assisted naturally ventilated double skin facade for buildings: Room impacts and indoor air quality

被引:11
作者
Tao, Yao [1 ]
Yan, Yihuan [1 ]
Fang, Xiang [1 ]
Zhang, Haihua [2 ]
Tu, Jiyuan [2 ]
Shi, Long [2 ]
机构
[1] Shanghai Univ Engn Sci, Sch Air Transportat Flying, Shanghai 201620, Peoples R China
[2] RMIT Univ, Sch Engn, Melbourne, Vic 3004, Australia
基金
澳大利亚研究理事会;
关键词
Natural ventilation; Double-skin facade; Solar irradiation; Renewable energy; CFD simulation; Indoor air quality; THERMAL PERFORMANCE; HEAT-TRANSFER; MEAN AGE; NODAL NETWORK; FLOW; CFD; CHIMNEY; SIMULATION; BEHAVIOR; DRIVEN;
D O I
10.1016/j.buildenv.2022.109002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Although the performance of naturally ventilation double-skin facade (NVDSF) assisted by solar radiation has been widely demonstrated for building energy saving, there are still several unsolved issues towards its application regarding the user space's side and its air quality. This study focuses on two aspects through validated CFD simulations: firstly, a theoretical model is calibrated for the use of an NVDSF connected to a room, with its validity examined by different solar intensities and applicable scenarios clarified; secondly, the age of air and ventilation efficiency under each scenario are evaluated. Results reveal the impacts due to air supply vent sizes, installation heights and aspect ratios, identify discounts in ventilation rates up to 14.8%, 15.3% and 2.9%, respectively. With a fixed air supply vent, different NVDSFs locations deliver almost identical natural ventilation rates (no more than 1.7% differences between cases), but significantly different indoor air quality - the difference in ventilation efficiencies can be up to 18%. An NVDSF located furthest to the air supply vent delivers the best indoor airflow distribution, with more fresh air coverage across the room and reduced bad circulation. The solar irradiation's (I) impact on natural ventilation rate (V) has been identified as V = 0.004I0.33 (new theoretical model) and V = 0.002I0.42 (CFD), which shows a good agreement with an average discrepancy of 6% for solar intensities 100-1000W/m2. This study highlights the importance of evaluating indoor air quality in addition to the ventilation rates for an NVDSF with a room, and provides a more accurate theoretical model for transition seasons' ventilation that can reflect impacts from solar intensities to assist in future strategy-making for mixedmode operations in buildings.
引用
收藏
页数:13
相关论文
共 50 条
[31]   Calculation of overall thermal transfer value (OTTV) for commercial buildings constructed with naturally ventilated double skin facade in subtropical Hong Kong [J].
Chan, A. L. S. ;
Chow, T. T. .
ENERGY AND BUILDINGS, 2014, 69 :14-21
[32]   Annual energy consumption evaluation of naturally ventilated double skin facade in hot summer and cold winter zone [J].
Chen, Youming ;
Li, Cong ;
Wang, Yanjin .
PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, :4369-4375
[33]   Summer performance of a naturally ventilated double-skin facade with adjustable glazed louvers for building energy retrofitting [J].
Lin, Zhenghao ;
Song, Yehao ;
Chu, Yingnan .
ENERGY AND BUILDINGS, 2022, 267
[34]   Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings [J].
Hummelgaard, J ;
Juhl, P ;
Sæbjörnsson, KO ;
Clausen, G ;
Toftum, J ;
Langkilde, G .
INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, :675-680
[35]   Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings [J].
Hummelgaard, J. ;
Juhl, P. ;
Saebjornsson, K. O. ;
Clausen, G. ;
Toftum, J. ;
Langkilde, G. .
BUILDING AND ENVIRONMENT, 2007, 42 (12) :4051-4058
[36]   Thermal Assessment of a Ventilated Double Skin Facade Component with a Set of Air Filtering Photocatalytic Slats in the Cavity [J].
Roig, Oriol ;
Cuerva, Eva ;
Pardal, Cristina ;
Guardo, Alfredo ;
Isalgue, Antonio ;
Lopez-Besora, Judit .
BUILDINGS, 2023, 13 (02)
[37]   Thermal performance analysis of naturally ventilated and perforated sheet based double skin facade system for hot summer conditions [J].
Sharma M.K. ;
Preet S. ;
Mathur J. ;
Chowdhury A. ;
Mathur S. .
International Journal of Ventilation, 2022, 21 (04) :263-283
[38]   Predicted thermal acceptance in naturally ventilated office buildings with double skin facades under Brazilian climates [J].
Barbosa, Sabrina ;
Ip, Kenneth .
JOURNAL OF BUILDING ENGINEERING, 2016, 7 :92-102
[39]   Indoor Air Quality in Naturally Ventilated Primary Schools: A Systematic Review of the Assessment & Impacts of CO2 Levels [J].
Honan, David ;
Gallagher, John ;
Garvey, John ;
Littlewood, John .
BUILDINGS, 2024, 14 (12)
[40]   Energy performance and applicability of naturally ventilated double skin facade with Venetian blinds in Yangtze River Area [J].
Wang, Yanjin ;
Chen, Youming ;
Li, Cong .
SUSTAINABLE CITIES AND SOCIETY, 2020, 61