Solar-assisted naturally ventilated double skin facade for buildings: Room impacts and indoor air quality

被引:9
作者
Tao, Yao [1 ]
Yan, Yihuan [1 ]
Fang, Xiang [1 ]
Zhang, Haihua [2 ]
Tu, Jiyuan [2 ]
Shi, Long [2 ]
机构
[1] Shanghai Univ Engn Sci, Sch Air Transportat Flying, Shanghai 201620, Peoples R China
[2] RMIT Univ, Sch Engn, Melbourne, Vic 3004, Australia
基金
澳大利亚研究理事会;
关键词
Natural ventilation; Double-skin facade; Solar irradiation; Renewable energy; CFD simulation; Indoor air quality; THERMAL PERFORMANCE; HEAT-TRANSFER; MEAN AGE; NODAL NETWORK; FLOW; CFD; CHIMNEY; SIMULATION; BEHAVIOR; DRIVEN;
D O I
10.1016/j.buildenv.2022.109002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Although the performance of naturally ventilation double-skin facade (NVDSF) assisted by solar radiation has been widely demonstrated for building energy saving, there are still several unsolved issues towards its application regarding the user space's side and its air quality. This study focuses on two aspects through validated CFD simulations: firstly, a theoretical model is calibrated for the use of an NVDSF connected to a room, with its validity examined by different solar intensities and applicable scenarios clarified; secondly, the age of air and ventilation efficiency under each scenario are evaluated. Results reveal the impacts due to air supply vent sizes, installation heights and aspect ratios, identify discounts in ventilation rates up to 14.8%, 15.3% and 2.9%, respectively. With a fixed air supply vent, different NVDSFs locations deliver almost identical natural ventilation rates (no more than 1.7% differences between cases), but significantly different indoor air quality - the difference in ventilation efficiencies can be up to 18%. An NVDSF located furthest to the air supply vent delivers the best indoor airflow distribution, with more fresh air coverage across the room and reduced bad circulation. The solar irradiation's (I) impact on natural ventilation rate (V) has been identified as V = 0.004I0.33 (new theoretical model) and V = 0.002I0.42 (CFD), which shows a good agreement with an average discrepancy of 6% for solar intensities 100-1000W/m2. This study highlights the importance of evaluating indoor air quality in addition to the ventilation rates for an NVDSF with a room, and provides a more accurate theoretical model for transition seasons' ventilation that can reflect impacts from solar intensities to assist in future strategy-making for mixedmode operations in buildings.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A review on applying ventilated double-skin facade to buildings in hot-summer and cold-winter zone in China
    Zhou, Juan
    Chen, Youming
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (04) : 1321 - 1328
  • [22] Modeling ventilation in naturally ventilated double-skin facade with a venetian blind
    Zeng, Zhen
    Li, Xiaofeng
    Li, Cheng
    Zhu, Yingxin
    BUILDING AND ENVIRONMENT, 2012, 57 : 1 - 6
  • [23] Double skin facade with Azolla; ventilation, Indoor Air Quality and Thermal Performance Assessment
    Parhizkar, Hooman
    Khoraskani, Roham Afghani
    Tahbaz, Mansoureh
    JOURNAL OF CLEANER PRODUCTION, 2020, 249
  • [24] A numerical study of indoor air quality in a ventilated room using different strategies of ventilation
    Koufi, L.
    Younsi, Z.
    Cherif, Y.
    Naji, H.
    El Ganaoui, M.
    MECHANICS & INDUSTRY, 2017, 18 (02)
  • [25] The impacts of facade and ventilation strategies on indoor thermal environment for a naturally ventilated residential building in Singapore
    Wang, LP
    Wong, NH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1320 - 1324
  • [26] The Impact of Traffic-Related Air Pollutants on the Indoor Air Quality of a Naturally Ventilated Building
    Tong, Zheming
    Chen, Yujiao
    Malkawi, Ali
    2017 ASHRAE WINTER CONFERENCE PAPERS, 2017,
  • [27] Coupling TRNSYS 17 and CONTAM: simulation of a naturally ventilated double-skin facade
    Khalifa, Ines
    Ernez, Leila Gharbi
    Znouda, Essia
    Bouden, Chiheb
    ADVANCES IN BUILDING ENERGY RESEARCH, 2015, 9 (02) : 293 - 304
  • [28] Experimental validation of a EnergyPlus model: Application of a multi-storey naturally ventilated double skin facade
    Andelkovic, Aleksandar S.
    Mujan, Igor
    Dakic, Stojanka
    ENERGY AND BUILDINGS, 2016, 118 : 27 - 36
  • [29] Coupled heat and mass transfer analysis for indoor air quality and thermal comfort in naturally ventilated offices
    Huang, Zhaopeng
    Li, Qiong
    He, Yiyuan
    Ding, Xiang
    Dong, Yunli
    Gao, Wenfeng
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [30] IMPROVING INDOOR AIR QUALITY OF NATURALLY VENTILATED CLASSROOMS IN THE NORTHEAST OF PORTUGAL
    Rodrigues, Filipe
    Feliciano, Manuel
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2019, 18 (07): : 1423 - 1437