Arterial pressure waveform analysis versus thermodilution cardiac output measurement during open abdominal aortic aneurysm repair A prospective observational study

被引:14
作者
Montenij, Leonard J. [1 ]
Buhre, Wolfgang F. [4 ]
de Jong, Steven A. [1 ]
Harms, Jeroen H. [1 ]
van Herwaarden, Joost A. [2 ]
Kruitwagen, Cas L. J. J. [3 ]
de Waal, Eric E. C.
机构
[1] Univ Med Ctr Utrecht, Dept Anaesthesiol, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Vasc Surg, NL-3584 CX Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Julius Ctr Biostat, NL-3584 CX Utrecht, Netherlands
[4] Maastricht Univ, Med Ctr, Dept Anaesthesia & Pain Therapy, Maastricht, Netherlands
关键词
MECHANICAL VENTILATION; LIVER-TRANSPLANTATION; FLUID RESPONSIVENESS; PULSE CONTOUR; PRECISION; ACCURACY; SURGERY; FLOTRAC/VIGILEO; METAANALYSIS; SOFTWARE;
D O I
10.1097/EJA.0000000000000160
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND Arterial pressure waveform analysis enables continuous, minimally invasive measurement of cardiac output. Haemodynamic instability compromises the reliability of the technique and a means of maintaining accurate measurement in this circumstance would be useful. OBJECTIVES To investigate the accuracy, precision and trending ability of arterial pressure waveform cardiac output obtained with FloTrac/Vigileo, versus pulmonary artery thermodilution in patients undergoing elective open abdominal aortic aneurysm repair. DESIGN A prospective observational study. SETTING Operating room in a university hospital. PATIENTS Twenty-two patients scheduled for elective, open abdominal aortic aneurysm repair. MAIN OUTCOME MEASURES Bias, limits of agreement and mean error as determined with Bland-Altman analysis between arterial waveform and thermodilution cardiac output assessment at four time points: after induction of anaesthesia (t(1)); after aortic cross-clamping (t(2)); after clamp release (t(3)); and after skin closure (t(4)). Trending ability from t(1) to t(2), t(2) to t(3) and t(3) to t(4), determined with four-quadrant and polar plot methodology. Clinically acceptable boundaries were defined in advance. RESULTS Bland-Altman analysis revealed a bias of 0.54 l min(-1) (thermodilution minus arterial waveform cardiac output) for pooled data, and 0.51 (t(1)), -0.42 (t(2)), 0.98 (t(3)) and 0.98 (t(4)) l min(-1) at the different time points. Limits of agreement (LOA) were [-3.0 to 4.0] (pooled), [-2.0 to 3.0] (t(1)), [-3.1 to 2.3] (t(2)), [-2.5 to 4.4] (t(3)) and [-1.7 to 3.7] (t(4)) l min(-1), resulting in mean errors of 58% (pooled), 45% (t(1)), 53% (t(2)), 52% (t(3)) and 41% (t(4)). Four-quadrant concordance was 65%. Polar plot analysis resulted in an angular bias of -12 degrees, with radial LOA of -60 degrees to 36 degrees. CONCLUSION Bias between arterial waveform and thermodilution cardiac output was within a predefined acceptable range, but the mean error was above the accepted range of 30%. Trending ability was poor. Arterial waveform and thermodilution cardiac outputs are, therefore, not interchangeable in patients undergoing open abdominal aortic aneurysm repair.
引用
收藏
页码:13 / 19
页数:7
相关论文
共 35 条
  • [1] Accuracy of arterial pressure waveform analysis for cardiac output measurement in comparison with thermodilution methods in patients undergoing living donor liver transplantation
    Akiyoshi, Kozaburo
    Kandabashi, Tadashi
    Kaji, Junko
    Yamaura, Ken
    Yoshimura, Hayashi
    Irita, Kazuo
    Hoka, Sumio
    [J]. JOURNAL OF ANESTHESIA, 2011, 25 (02) : 178 - 183
  • [2] Cardiac output monitoring: an integrative perspective
    Alhashemi, Jamal A.
    Cecconi, Maurizio
    Hofer, Christoph K.
    [J]. CRITICAL CARE, 2011, 15 (02):
  • [3] [Anonymous], 2008, Curr Anaesth Crit Care, DOI [10.1016/j.cacc.2008.07.001, DOI 10.1016/J.CACC.2008.07.001]
  • [4] Aronow WS, 2011, MINERVA MED, V102, P483
  • [5] The effect of anaesthesia and aortic clamping on cardiac output measurement using arterial pulse power analysis during aortic aneurysm repair
    Beattie, C.
    Moores, C.
    Thomson, A. J.
    Nimmo, A. F.
    [J]. ANAESTHESIA, 2010, 65 (12) : 1194 - 1199
  • [6] Evaluation of a New Software Version of the FloTrac/Vigileo (Version 3.02) and a Comparison with Previous Data in Cirrhotic Patients Undergoing Liver Transplant Surgery
    Biancofiore, Gianni
    Critchley, Lester A. H.
    Lee, Anna
    Yang, Xiao-xing
    Bindi, Lucia M.
    Esposito, Massimo
    Bisa, Massimo
    Meacci, Luca
    Mozzo, Roberto
    Filipponi, Franco
    [J]. ANESTHESIA AND ANALGESIA, 2011, 113 (03) : 515 - 522
  • [7] Measuring agreement in method comparison studies
    Bland, JM
    Altman, DG
    [J]. STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) : 135 - 160
  • [8] Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - with specific reference to the measurement of cardiac output
    Cecconi, Maurizio
    Rhodes, Andrew
    Poloniecki, Jan
    Della Rocca, Giorgio
    Grounds, R. Michael
    [J]. CRITICAL CARE, 2009, 13 (01):
  • [9] A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    Critchley, LAH
    Critchley, JAJH
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) : 85 - 91
  • [10] Assessment of Trending Ability of Cardiac Output Monitors by Polar Plot Methodology
    Critchley, Lester A.
    Yang, Xiao X.
    Lee, Anna
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (03) : 536 - 546