An improved method for simultaneous analysis of aminothiols in human plasma by high-performance liquid chromatography with fluorescence detection

被引:47
作者
Cevasco, Giorgio [1 ,2 ]
Piatek, Anna Maria [1 ]
Scapolla, Carlo [1 ]
Thea, Sergio [1 ]
机构
[1] Univ Genoa, Dept Chem & Ind Chem, I-16146 Genoa, Italy
[2] CNR, Inst Chem Methodol, Rome, Italy
关键词
Aminothiols; Benzofurazan; Derivatization; Fluorescence; HPLC; Human plasma; FLUOROGENIC REAGENT; TOTAL HOMOCYSTEINE; CYSTEINE; THIOLS; QUANTIFICATION; DERIVATIZATION; CYSTEAMINE; URINE;
D O I
10.1016/j.chroma.2010.02.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Altered levels of aminothiols in biological fluids are thought to be an important risk indicator for several diseases, and reliable methods for the accurate determination of aminothiols concentrations in plasma are thus required. In this paper ammonium 5-bromo-7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (SBD-BF) is proposed as a convenient fluorogenic derivatizating reagent for the determination of aminothiols (cysteine, cysteinylglycine, homocysteine and glutathione) by HPLC with fluorescence detection. The reactions of SBD-BF with aminothiols at room temperature are about three-times faster than those of ammonium 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (the most frequently employed reagent) at 60 C. The derivatives of SBD-BF with cysteine, cysteinylglycine, homocysteine and glutathione are easily separated by HPLC and their calibration curves show excellent linearity over the range 0.05-20 mu mol/L with excellent r(2) values for all analytes. SBD-BF reacts with thiols under mild conditions, i.e. at 25 degrees C over about 30 min, and is proposed as a suitable fluorogenic reagent for thiol derivatization to be introduced in analytical clinical chemistry. The detection limits of Cys, Cys-Gly, Hcy and GSH at a signal-to-noise ratio of 5 were 0.1 mu M for Cys, 0.01 mu M for Cys-Gly and Hcy, and 0.02 mu M for GSH. Furthermore, validation parameters of the proposed method are quite satisfactory. As an application of this method the determination of thiol derivatives in human plasma was carried out on a number of samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2158 / 2162
页数:5
相关论文
共 24 条
[1]   Analysis of plasma thiols by high-performance liquid chromatography with ultraviolet detection [J].
Bald, E ;
Chwatko, G ;
Glowacki, R ;
Kusmierek, K .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1032 (1-2) :109-115
[2]   Determination of plasma aminothiols by high performance liquid chromatography after precolumn derivatization with N-(2-acridonyl)maleimide [J].
Benkova, Bistra ;
Lozanov, Valentin ;
Ivanov, Ivaylo P. ;
Todorova, Antonia ;
Milanov, Ivan ;
Mitev, Vanio .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 870 (01) :103-108
[3]   Ammonium 5-bromo-7-fluorobenzo-2oxa-1,3-diazole-4-sulphonate: A new fluorogenic reagent for the determination of aminothiols by HPLC [J].
Cevasco, Giorgio ;
Mumot, Anna Maria ;
Scapolla, Carlo ;
Thea, Sergio .
CLINICAL CHEMISTRY, 2007, 53 (12) :2221-2222
[4]   OXIDATION OF SUBSTITUTED ANILINES TO NITROSO-COMPOUNDS [J].
DINUNNO, L ;
FLORIO, S ;
TODESCO, PE .
JOURNAL OF THE CHEMICAL SOCIETY C-ORGANIC, 1970, (10) :1433-&
[5]   Methods for homocysteine analysis and biological relevance of the results [J].
Ducros, V ;
Demuth, K ;
Sauvant, MP ;
Quillard, M ;
Caussé, E ;
Candito, M ;
Read, MH ;
Drai, J ;
Garcia, I ;
Gerhardt, MF .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 781 (1-2) :207-226
[6]   Rapid measurement of total plasma homocysteine by HPLC [J].
Frick, B ;
Schröcksnadel, K ;
Neurauter, G ;
Wirleitner, B ;
Artner-Dworzak, E ;
Fuchs, D .
CLINICA CHIMICA ACTA, 2003, 331 (1-2) :19-23
[7]   Plasma total homocysteine quantification: an improvement of the classical high-performance liquid chromatographic method with fluorescence detection of the thiol-SBD derivatives [J].
Garcia, AJ ;
Apitz-Castro, R .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 779 (02) :359-363
[8]  
HANSON JR, 2004, J CHEM RES S, V10, P699
[9]   Quantification of intracellular homocysteine by stable isotope dilution liquid chromatography/tandem mass spectrometry [J].
Huang, Yuehua ;
Lu, Zhi-Yong ;
Brown, Karen S. ;
Whitehead, Alexander S. ;
Blair, Ian A. .
BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (01) :107-112
[10]   A validated HPLC-fluorescence method with a semi-micro column for routine determination of homocysteine, cysteine and cysteamine, and the relation between the thiol derivatives in normal human plasma [J].
Ichinose, Saori ;
Nakamura, Mayumi ;
Maeda, Mayu ;
Ikeda, Rie ;
Wada, Mitsuhiro ;
Nakazato, Mio ;
Ohba, Yoshihito ;
Takamura, Noboru ;
Maeda, Takahiro ;
Aoyagi, Kiyoshi ;
Nakashima, Kenichiro .
BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (09) :935-939