Real-time 3D surface-image-guided beam setup in radiotherapy of breast cancer

被引:53
作者
Djajaputra, D [1 ]
Li, SD [1 ]
机构
[1] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21231 USA
关键词
breast cancer; image-guided radiotherapy; 3D surface image;
D O I
10.1118/1.1828251
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We describe an approach for external beam radiotherapy of breast cancer that utilizes the three-dimensional (3D) surface information of the breast. The surface data of the breast are obtained from a 3D optical camera that is rigidly mounted on the ceiling of the treatment vault. This 3D camera utilizes light in the visible range therefore it introduces no ionization radiation to the patient. In addition to the surface topographical information of the treated area, the camera also captures gray-scale information that is overlaid on the 3D surface image. This allows us to visualize the skin markers and automatically determine the isocenter position and the beam angles in the breast tangential fields. The field sizes and shapes of the tangential, supraclavicular, and internal mammary gland fields can all be determined according to the 3D surface image of the target. A least-squares method is first introduced for the tangential-field setup that is useful for compensation of the target shape changes. The entire process of capturing the 3D surface data and subsequent calculation of beam parameters typically requires less than 1 min. Our tests on phantom experiments and patient images have achieved the accuracy of 1 mm in shift and 0.5degrees in rotation. Importantly, the target shape and position changes in each treatment session can both be corrected through this real-time image-guided system. (C) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:65 / 75
页数:11
相关论文
共 37 条
[1]  
Aref A, 1998, Med Dosim, V23, P15, DOI 10.1016/S0958-3947(97)00116-7
[2]   Methods for modeling and predicting mechanical deformations of the breast under external perturbations [J].
Azar, FS ;
Metaxas, DN ;
Schnall, MD .
MEDICAL IMAGE ANALYSIS, 2002, 6 (01) :1-27
[3]   Evaluation of methods for opto-electronic body surface sensing applied to patient position control in breast radiation therapy [J].
Baroni, G ;
Troia, A ;
Riboldi, M ;
Orecchia, R ;
Ferrigno, G ;
Pedotti, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (06) :679-688
[4]  
Baroni G, 2000, Comput Aided Surg, V5, P296, DOI 10.3109/10929080009148897
[5]   Real-time three-dimensional motion analysis for patient positioning verification [J].
Baroni, G ;
Ferrigno, G ;
Orecchia, R ;
Pedotti, A .
RADIOTHERAPY AND ONCOLOGY, 2000, 54 (01) :21-27
[6]  
*BRIT STAND I, 1993, 61217 BS EN
[7]   MATCHING OF ADJACENT RADIATION BEAMS FOR ISOCENTRIC RADIOTHERAPY [J].
CASEBOW, MP .
BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (680) :735-740
[8]   The use of an optical outlining system for weekly on-set verification of patients with carcinoma of the breast [J].
Casebow, MP ;
Harris, RL ;
Jarvis, RJ .
RADIOTHERAPY AND ONCOLOGY, 1998, 46 (01) :99-103
[9]   A NONDIVERGENT 3 FIELD MATCHING TECHNIQUE FOR BREAST IRRADIATION [J].
CHU, JCH ;
SOLIN, LJ ;
HWANG, CC ;
FOWBLE, B ;
HANKS, GE ;
GOODMAN, RL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (04) :1037-1040
[10]   3-FIELD ISOCENTRIC TECHNIQUE FOR BREAST IRRADIATION USING INDIVIDUALIZED SHIELDING BLOCKS [J].
CONTE, G ;
NASCIMBEN, O ;
TURCATO, G ;
POLICO, R ;
IDI, MB ;
BELLERI, LM ;
BERGOGLIO, F ;
SIMONATO, F ;
STEA, L ;
BUGIN, F ;
BORTOT, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (06) :1299-1305