Fetal pulse oximetry - A methodological study

被引:13
作者
Maesel, A
Martensson, L
Gudmundsson, S
Marsal, K
机构
[1] Dept. of Obstetrics and Gynecology, University of Lund, University Hospital MAS, Malmö
[2] Dept. of Obstetrics and Gynecology, University Hospital MAS
关键词
fetal; labor; pulse oximetry;
D O I
10.3109/00016349609033307
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background. During recent years fetal pulse oximetry has been under development for use in monitoring fetal oxygenation during labor. In a methodological study we have tested the practical applicability of one type of sensor (FS-IO Oxisensor, Nellcor(R)). Both obstetricians and midwives took active part in sensor placement. The readings of fetal arterial oxygen saturation (SpO(2)) were not taken into account when managing the patients. Methods. Oxygenation was monitored during labor in 96 singleton pregnancies, Mean SpO(2) levels were calculated when cervical dilatation was 4-7 cm and 8-10 cm. and in the second stage of labor. Student's t-test was used for paired comparisons. A p-value<0.05 was considered significant. Results. Of the 96 oxisensors. 91 (95%) were successfully placed. One mother felt pain which disappeared when the sensor was removed. Two of the newborns manifested an impression mark caused by the sensor, which disappeared completely within a day No infection or increased bleeding was noted. The mean recording lime was 134 minutes. SpO(2)-values were obtainable during 69% of the recording time. A significant fall of mean SpO(2) occurred between the first and second stages of labor. Conclusions. The method seems to be harmless for mother and child. and allows SpO(2)-values to be obtained during two thirds of the recording period. Further research is needed to evaluate the possible clinical value of the method.
引用
收藏
页码:144 / 148
页数:5
相关论文
共 16 条
[1]  
AMANO K, 1994, HYPOXISCHE GEFAHRDUN, P83
[2]  
CARBONNE B, 1994, HYPOXISCHE GEFAHRDUN, P203
[3]  
DILDY GA, 1993, OBSTET GYNECOL, V81, P630
[4]   INTRAPARTUM FETAL PULSE OXIMETRY - FETAL OXYGEN-SATURATION TRENDS DURING LABOR AND RELATION TO DELIVERY OUTCOME [J].
DILDY, GA ;
VANDENBERG, PP ;
KATZ, M ;
CLARK, SL ;
JONGSMA, HW ;
NIJHUIS, JG ;
LOUCKS, CA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) :679-684
[5]  
GARDOSI J, 1994, HYPOXISCHE GEFAHRDUN, P179
[6]   ARTIFACTS IN FETAL PULSE OXIMETRY - INCOMPLETE SENSOR-TO-SKIN CONTACT [J].
GARDOSI, JO ;
DAMIANOU, D ;
SCHRAM, CMH .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 170 (04) :1169-1173
[7]  
JOHNSON N, 1991, J PERINAT MED, V19, P297
[8]  
Johnson N., 1994, Journal of Obstetrics and Gynaecology (Abingdon), V14, P11, DOI 10.3109/01443619409025955
[9]   MONITORING THE FETUS WITH A SENSOR COVERED WITH AN IRREGULAR SURFACE CAN CAUSE SCALP ULCERATION [J].
JOHNSON, N ;
MCNAMARA, H .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1993, 100 (10) :961-963
[10]   ADHERENCE IN CHILDHOOD DIABETES - RESULTS OF A CONFIRMATORY FACTOR-ANALYSIS [J].
JOHNSON, SB ;
TOMER, A ;
CUNNINGHAM, WR ;
HENRETTA, JC .
HEALTH PSYCHOLOGY, 1990, 9 (04) :493-501