Distribution of Absorbed Dose in Cone-Beam Breast Computed Tomography: a Phantom Study with Radiochromic Films

被引:0
作者
Russo, Paolo [1 ]
Coppola, Teresa [1 ]
Mettivier, Giovanni [1 ]
Montesi, Maria Cristina [1 ]
Lauria, Adele [1 ]
机构
[1] Univ Naples Federico II, Lab Med Phys, Dipartimento Sci Fis, I-80126 Naples, Italy
来源
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2009年
关键词
CT; GEOMETRY;
D O I
10.1109/NSSMIC.2009.5401788
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cone-Beam Breast Computed Tomography (CBBCT) of the pendant breast with dedicated scanners is an experimental X-ray 3-D imaging technique for breast cancer diagnosis under evaluation in comparison to conventional two-view 2-D mammography of the compressed breast. In CBBCT it is generally assumed that a more uniform distribution of the radiation dose to the breast volume can be obtained, with respect to mammography, at equal Mean Glandular Dose (MGD) levels. In fact, in CBBCT the X-ray beam rotates for 360 deg around the breast, while in a mammography view the breast is irradiated from one side only. Using a CBBCT laboratory scanner developed by our group, we have measured the distribution of the radiation dose in a hemi-ellipsoidal PMMA breast phantom of 14 cm diameter simulating the average uncompressed breast, using radiochromic films type XR-SP inserted at mid-plane in the phantom. The technique factors were 80 kVp (5.6 mm AI Half Value Layer), tube load 23-100 mAs, for an air kerma at isocenter in the range 4.7-20 mGy, corresponding to a MGD of 3.3-15.8 mGy for a 14 cm diameter breast of 50% glandularity. Results indicate a relative dose variation Delta = ((edge-center)/center) up to 25% at a distance of 50 mm from the nipple. As for the relative dose variation along the phantom longitudinal axis, the maximum value measured is delta = ((nipple-chest wall)/chest wall) = -15%, indicating that the dose decreases from the chest wall toward the nipple. The values of the parameters Delta and delta depend also on the height of the X-ray tube focal spot with respect to the phantom vertex (nipple).
引用
收藏
页码:3463 / 3470
页数:8
相关论文
共 19 条
[1]   Technique factors and their relationship to radiation dose in pendant geometry breast CT [J].
Boone, JM ;
Kwan, ALC ;
Seibert, JA ;
Shah, N ;
Lindfors, KK ;
Nelson, TR .
MEDICAL PHYSICS, 2005, 32 (12) :3767-3776
[2]   Dedicated breast CT: Radiation dose and image quality evaluation [J].
Boone, JM ;
Nelson, TR ;
Lindfors, KK ;
Seibert, JA .
RADIOLOGY, 2001, 221 (03) :657-667
[3]   Cone-beam volume CT breast imaging: Feasibility study [J].
Chen, B ;
Ning, R .
MEDICAL PHYSICS, 2002, 29 (05) :755-770
[4]   Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography [J].
Crotty, D. J. ;
McKinley, R. L. ;
Tornai, M. P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (03) :603-616
[5]  
*FOOD DRUG ADM, MAMM QUAL STAND FIN
[6]   Breast CT [J].
Glick, Stephen J. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2007, 9 :501-526
[7]   Dedicated breast CT: Initial clinical experience [J].
Lindfors, Karen K. ;
Boone, John M. ;
Nelson, Thomas R. ;
Yang, Kai ;
Kwan, Alexander L. C. ;
Miller, DeWitt F. .
RADIOLOGY, 2008, 246 (03) :725-733
[8]   Analysis of a novel offset cone-beam computed mammotomography system geometry for accomodating various breast sizes [J].
McKinley, Randolph L. ;
Tornai, Martin P. ;
Brzymialkiewicz, Caryl ;
Madhav, Priti ;
Samei, Ehsan ;
Bowsher, James E. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2006, 21 :48-55
[9]   Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55 [J].
Niroomand-Rad, A ;
Blackwell, CR ;
Coursey, BM ;
Gall, KP ;
Galvin, JM ;
McLaughlin, WL ;
Meigooni, AS ;
Nath, R ;
Rodgers, JE ;
Soares, CG .
MEDICAL PHYSICS, 1998, 25 (11) :2093-2115
[10]  
O'Connell A.M., 2009, Journal of Radiology Nursing, V28, P3