Surface and Interface Charge Accumulation and Decay of Oil-paper Insulation under DC Voltage

被引:18
作者
Du, B. X. [1 ]
Zhu, W. B. [1 ]
Zhang, J. G. [2 ]
Li, X. L. [1 ]
机构
[1] Tianjin Univ, Sch Elect & Informat Engn, Key Lab Smart Grid, Educ Minist, Tianjin 300072, Peoples R China
[2] State Grid Cangzhou Power Supply Co, Cangzhou 061001, Hebei, Peoples R China
关键词
Converter transformer; HVDC bushings; interface charge; surface potential; trap; charge accumulation; charge decay; PERFORMANCE;
D O I
10.1109/TDEI.2017.006153
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Oil-paper insulation system is an extraordinarily essential system of converter transformer as well as HVDC bushing. This paper studies the interface charge accumulation and dissipation characteristics of oil-paper insulation system under DC voltage. In this paper, an induced electrification was used to charge the oil-paper samples. The amplitudes of the DC voltage varied from 1 to 4 kV and the paper was 0.13 mm in thickness. From the research of different voltage amplitudes and charging times of the paper, conclusions can be drawn that the decay is fast initially, and then becomes slower with the lapse of time. At last the dissipation trend tends to be flat. With the increase of the voltage amplitudes, the surface potential rises more rapidly, and higher voltage would also cause the charge to dissipate more quickly. Longer charging times would cause the charge to dissipate a bit more slowly. The decay rate of the negative voltage is a little smaller than that of the positive charge. Moreover, when it comes to the effect on the interface charge of the paper layers, the surface potential is more proportional to the increase of paper layers. When the amplitude of the voltage applied in the test is small or the charging time is short enough, the interface charge can be hardly accumulated on the bottom layer. In addition, the tdV/dt and the decay time curves under the positive voltage usually have two peak values, while there is only one peak value in most of the curves under the negative condition.
引用
收藏
页码:939 / 946
页数:8
相关论文
共 26 条
[1]  
[Anonymous], HIGH VOLTAFE ENG
[2]  
[Anonymous], IEEE INT C PROP APPL
[3]  
[Anonymous], IEEE T DIELECTR ELEC
[4]  
[Anonymous], IEEE INT S EL
[5]  
[Anonymous], 2004, 606412 IEC
[6]  
Arora R, 2011, HIGH VOLTAGE AND ELECTRICAL INSULATION ENGINEERING, P1, DOI 10.1002/9780470947906
[7]   Surface Charge Accumulation and Decay of Direct-fluorinated RTV Silicone Rubber [J].
Du, B. X. ;
Li, Z. L. ;
Li, Jie .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (05) :2338-2342
[8]   Dynamic Behavior of Surface Charge on Direct-fluorinated Polyimide Films [J].
Du, B. X. ;
Li, Jie ;
Du, Wei .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (03) :947-954
[9]   Creepage discharge characteristics over solid-liquid interfaces with grounded side electrode [J].
Hanaoka, R ;
Kohrin, T ;
Miyagawa, T ;
Nishi, T .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (02) :308-315
[10]   DIELECTRIC PERFORMANCE OF IMPROVED GAS INSULATED BUSHING FOR UHV GIS [J].
HOSOKAWA, M ;
OKUMURA, K ;
YAMAGIWA, T ;
ISHIKAWA, T ;
OZAWA, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 1987, 2 (02) :359-366