Platelet-Derived Microparticles Generated by Neonatal Extracorporeal Membrane Oxygenation Systems

被引:27
|
作者
Meyer, Andrew D. [1 ]
Gelfond, Jonathan A. L. [2 ]
Wiles, Andrew A. [3 ]
Freishtat, Robert J. [3 ]
Rais-Bahrami, Khoydar [4 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Pediat, Div Pediat Crit Care, San Antonio, TX 78229 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, Dept Epidemiol & Biostat, San Antonio, TX 78229 USA
[3] Childrens Natl Med Ctr, Dept Integrat Syst Biol, Washington, DC 20010 USA
[4] Children Natl Med Ctr, Ctr Hosp Based Subspecialties, Div Neonatol, Washington, DC USA
关键词
cardiopulmonary bypass; ECMO; flow cytometry; cell-derived microparticles; blood platelets; hemolysis; LIFE-SUPPORT ORGANIZATION; CARDIOPULMONARY BYPASS; FLOW-CYTOMETRY; TISSUE FACTOR; SHEAR-STRESS; WHOLE-BLOOD; DEVICES; PROCOAGULANT; ACTIVATION; THROMBOSIS;
D O I
10.1097/MAT.0000000000000164
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Current anticoagulation strategies do not eliminate thromboembolic stroke or limb loss during neonatal extracorporeal membrane oxygenation (ECMO), a form of cardiopulmonary bypass (CPB). In adults, CPB surgery generates prothrombotic platelet-derived microparticles (PMPs), submicron membrane vesicles released from activated platelets. However, information on PMP generation in neonatal ECMO systems is lacking. The objective of this study was to compare PMP generation in five different neonatal ECMO systems, using a simulated circuit with swine blood at 300 ml/min for 4 hours. Systems were composed of both newer components (centrifugal pump and hollow-fiber oxygenator) and traditional components (roller-head pump and silicone membrane oxygenator). Free plasma hemoglobin levels were measured as an indicator of hemolysis and flow cytometry-measured PMP. Hemolysis generated in all ECMO systems was similar to that observed in noncirculated static blood (p = 0.48). There was no difference in net PMP levels between different oxygenators with a given pump. In contrast, net PMP generation in ECMO systems with a centrifugal pump was at least 2.5 times greater than in roller-head pump systems. This was significant when using either a hollow-fiber (p < 0.005) or a silicone membrane (p < 0.05) oxygenator. Future studies are needed to define the relationship between pump-generated PMP and thrombosis.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [41] Circulating and platelet-derived microparticles in human blood enhance thrombosis on atherosclerotic plaques
    Suades, Rosa
    Padro, Teresa
    Vilahur, Gemma
    Badimon, Lina
    THROMBOSIS AND HAEMOSTASIS, 2012, 108 (06) : 1208 - 1219
  • [42] Plasma Levels of Platelet-Derived Microparticles in Patients with Obstructive Sleep Apnea Syndrome
    Maruyama, Keiko
    Morishita, Eriko
    Sekiya, Akiko
    Omote, Mika
    Kadono, Tadaaki
    Asakura, Hidesaku
    Hashimoto, Masami
    Kobayashi, Masako
    Nakatsumi, Yasuto
    Takada, Shigeo
    Ohtake, Shigeki
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2012, 19 (01) : 98 - 104
  • [43] Development of a NanoBioAnalytical platform for "on-chip" qualification and quantification of platelet-derived microparticles
    Obeid, Sameh
    Ceroi, Adam
    Mourey, Guillaume
    Saas, Philippe
    Elie-Caille, Celine
    Boireau, Wilfrid
    BIOSENSORS & BIOELECTRONICS, 2017, 93 : 250 - 259
  • [44] DETECTION OF PLATELET-DERIVED MICROPARTICLES USING FLOW CYTOMETRY AND ITS CLINICAL APPLICATION
    崔巍
    马文新
    林其燧
    韩晔华
    ChineseMedicalSciencesJournal, 2003, (01) : 26 - 30
  • [45] Platelet-Derived Microparticles and Platelet Function Profile in Children With Congenital Heart Disease
    Ismail, Eman Abdel Rahman
    Youssef, Omneya Ibrahim
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2013, 19 (04) : 424 - 432
  • [46] Plasma Platelet-derived Microparticles in Patients with Connective Tissue Diseases
    Oyabu, Chinami
    Morinobu, Akio
    Sugiyama, Daisuke
    Saegusa, Jun
    Tanaka, Shino
    Morinobu, Sahoko
    Tsuji, Goh
    Kasagi, Shimpei
    Kawano, Seiji
    Kumagai, Shunichi
    JOURNAL OF RHEUMATOLOGY, 2011, 38 (04) : 680 - 684
  • [47] Circulating microparticles as biomarkers of stroke: A focus on the value of endothelial- and platelet-derived microparticles
    El-Gamal, Heba
    Parray, Aijaz S.
    Mir, Fayaz A.
    Shuaib, Ashfaq
    Agouni, Abdelali
    JOURNAL OF CELLULAR PHYSIOLOGY, 2019, 234 (10) : 16739 - 16754
  • [48] Advances in Neonatal Extracorporeal Support The Role of Extracorporeal Membrane Oxygenation and the Artificial Placenta
    Gray, Brian W.
    Shaffer, Andrew W.
    Mychaliska, George B.
    CLINICS IN PERINATOLOGY, 2012, 39 (02) : 311 - +
  • [49] Effects of febuxostat on platelet-derived microparticles and adiponectin in patients with hyperuricema
    Nishizawa, Tohru
    Taniura, Takehito
    Nomura, Shosaku
    BLOOD COAGULATION & FIBRINOLYSIS, 2015, 26 (08) : 887 - 892
  • [50] Platelet Function During Extracorporeal Membrane Oxygenation in Adult Patients: A Systematic Review
    Balle, Camilla Mains
    Jeppesen, Anni Norgaard
    Christensen, Steffen
    Hvas, Anne-Mette
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2018, 5