Platelet-Derived Microparticles Generated by Neonatal Extracorporeal Membrane Oxygenation Systems

被引:27
|
作者
Meyer, Andrew D. [1 ]
Gelfond, Jonathan A. L. [2 ]
Wiles, Andrew A. [3 ]
Freishtat, Robert J. [3 ]
Rais-Bahrami, Khoydar [4 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Pediat, Div Pediat Crit Care, San Antonio, TX 78229 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, Dept Epidemiol & Biostat, San Antonio, TX 78229 USA
[3] Childrens Natl Med Ctr, Dept Integrat Syst Biol, Washington, DC 20010 USA
[4] Children Natl Med Ctr, Ctr Hosp Based Subspecialties, Div Neonatol, Washington, DC USA
关键词
cardiopulmonary bypass; ECMO; flow cytometry; cell-derived microparticles; blood platelets; hemolysis; LIFE-SUPPORT ORGANIZATION; CARDIOPULMONARY BYPASS; FLOW-CYTOMETRY; TISSUE FACTOR; SHEAR-STRESS; WHOLE-BLOOD; DEVICES; PROCOAGULANT; ACTIVATION; THROMBOSIS;
D O I
10.1097/MAT.0000000000000164
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Current anticoagulation strategies do not eliminate thromboembolic stroke or limb loss during neonatal extracorporeal membrane oxygenation (ECMO), a form of cardiopulmonary bypass (CPB). In adults, CPB surgery generates prothrombotic platelet-derived microparticles (PMPs), submicron membrane vesicles released from activated platelets. However, information on PMP generation in neonatal ECMO systems is lacking. The objective of this study was to compare PMP generation in five different neonatal ECMO systems, using a simulated circuit with swine blood at 300 ml/min for 4 hours. Systems were composed of both newer components (centrifugal pump and hollow-fiber oxygenator) and traditional components (roller-head pump and silicone membrane oxygenator). Free plasma hemoglobin levels were measured as an indicator of hemolysis and flow cytometry-measured PMP. Hemolysis generated in all ECMO systems was similar to that observed in noncirculated static blood (p = 0.48). There was no difference in net PMP levels between different oxygenators with a given pump. In contrast, net PMP generation in ECMO systems with a centrifugal pump was at least 2.5 times greater than in roller-head pump systems. This was significant when using either a hollow-fiber (p < 0.005) or a silicone membrane (p < 0.05) oxygenator. Future studies are needed to define the relationship between pump-generated PMP and thrombosis.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [31] Extracorporeal Membrane Oxygenation for Neonatal Respiratory Failure
    Betit, Peter
    Craig, Nancy
    RESPIRATORY CARE, 2009, 54 (09) : 1244 - 1251
  • [32] Acquired infection during neonatal and pediatric extracorporeal membrane oxygenation
    Cashen, Katherine
    Reeder, Ron
    Dalton, Heidi J.
    Berg, Robert A.
    Shanley, Thomas P.
    Newth, Christopher J. L.
    Pollack, Murray M.
    Wessel, David
    Carcillo, Joseph
    Harrison, Rick
    Dean, J. Michael
    Tamburro, Robert
    Meert, Kathleen L.
    PERFUSION-UK, 2018, 33 (06): : 472 - 482
  • [33] Outcomes following routine antithrombin III replacement during neonatal extracorporeal membrane oxygenation
    Stansfield, Brian K.
    Wise, Linda
    Ham, P. Benson, III
    Patel, Pinkal
    Parman, Malinda
    Jin, Chan
    Mathur, Sunil
    Harshfield, Gregory
    Bhatia, Jatinder
    JOURNAL OF PEDIATRIC SURGERY, 2017, 52 (04) : 609 - 613
  • [34] Prognostic value of cerebral tissue oxygen saturation during neonatal extracorporeal membrane oxygenation
    Clair, Marie-Philippine
    Rambaud, Jerome
    Flahault, Adrien
    Guedj, Romain
    Guilbert, Julia
    Guellec, Isabelle
    Durandy, Amelie
    Demoulin, Maryne
    Jean, Sandrine
    Mitanchez, Delphine
    Chalard, Francois
    Sileo, Chiara
    Carbajal, Ricardo
    Renolleau, Sylvain
    Leger, Pierre-Louis
    PLOS ONE, 2017, 12 (03):
  • [35] Impact of an inline extracorporeal membrane oxygenation hemofilter system in neonatal acute kidney injury
    Azar, Mohammed
    Alamir, Abdulrahman
    Al Qahtani, Abdullah Thabet
    Khamisa, Al Mokali
    Alfakeeh, Khalid
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2018, 14 : 811 - 816
  • [36] Apheresis platelet concentrates contain platelet-derived and endothelial cell-derived microparticles
    Rank, A.
    Nieuwland, R.
    Liebhardt, S.
    Iberer, M.
    Gruetzner, S.
    Toth, B.
    Pihusch, R.
    VOX SANGUINIS, 2011, 100 (02) : 179 - 186
  • [37] Platelet-derived microparticles and their cargos: The past, present and future
    Guo, Jingwen
    Cui, Bufeng
    Zheng, Jie
    Yu, Chang
    Zheng, Xuran
    Yi, Lixin
    Zhang, Simeng
    Wang, Keke
    ASIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2024, 19 (02)
  • [38] Antiplatelet Agents Inhibit the Generation of Platelet-Derived Microparticles
    Giacomazzi, Alice
    Degan, Maurizio
    Calabria, Stefano
    Meneguzzi, Alessandra
    Minuz, Pietro
    FRONTIERS IN PHARMACOLOGY, 2016, 7
  • [39] Changes in thyroid hormone concentrations during neonatal extracorporeal membrane oxygenation
    Leeuwen, L.
    van Heijst, A. F. J.
    van Rosmalen, J.
    de Rijke, Y. B.
    Beurskens, L. W. J. E.
    Tibboel, D.
    van den Akker, E. L. T.
    Usselstijn, H.
    JOURNAL OF PERINATOLOGY, 2017, 37 (08) : 906 - 910
  • [40] Therapeutic Hypothermia for Neonatal Encephalopathy and Extracorporeal Membrane Oxygenation
    Massaro, An
    Rais-Bahrami, Khodayar
    Chang, Taeun
    Glass, Penny
    Short, Billie Lou
    Baumgart, Stephen
    JOURNAL OF PEDIATRICS, 2010, 157 (03) : 499 - U192