Tomographic late evaluation of xenogeneic bone grafts in sockets o impacted third molars

被引:7
作者
Ferreira Junior, Osny [1 ]
Munhoz, Etiene Andrade [2 ]
Segantin, Jessica de Fatima [1 ]
Goncales, Eduardo Sanches [1 ]
Perri de Carvalho, Paulo Sergio [1 ]
机构
[1] Univ Sao Paulo, Fac Odontol Bauru, Dept Cirurgia Estomatol Patol & Radiol, Alameda Octavio Pinheiro Brisolla 9-75, BR-17012901 Bauru, SP, Brazil
[2] Univ Fed Santa Catarina, Ctr Ciencias Saude, Dept Estomatol, Florianopolis, SC, Brazil
关键词
Tomography; Heterografts; Third molar; Bone regeneration; BEAM COMPUTED-TOMOGRAPHY; PANORAMIC RADIOGRAPHY; ALVEOLAR CREST; EXTRACTION; SITES; LEVEL;
D O I
10.1590/1678-7757-2017-0396
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
It is necessary to preserve height and thickness of the alveolar bone to facilitate rehabilitation with osteointegratable implants or simply to maintain bone integrity after extraction. Biomaterials associated with resorbable or non-resorbable membranes, when placed in the region of the socket, may contribute to avoid this unwanted reabsorption. Objective: The objective of this study was to evaluate the distance of the crest of alveolar ridge to the cementoenamel junction (CD) of the lower second molars and the bone density of the third molar socket filled with Gen-Ted (R), 5 years after an exodontia using cone beam computed tomography (CBCT) to visualize the central region of the sockets, without overlapping of the buccal and lingual cortical bones. Material and Methods: A total of 12 individuals from an initial group of 39 patients submitted to extraction of the unruptured lower third molars and grafting of an association of inorganic bovine bone matrix, organic bovine bone matrix, collagen and bone morphogenetic proteins (BMP) (Gen-Techo (R)) on one side and the contralateral sockets filled only by clot, returned to control after 5 years, and were submitted to CBCT. The distance from the crest of alveolar bone to the CH and the bone density (BD) were measured using the i-CAT Vision Software. Results: The results showed that the distance from the crest of alveolar bone to the CH in the control group was similar to that observed before the exodontia; in the experimental group, this distance was smaller. Considering the BD measurement, a significantly higher density was observed in the experimental group (p<0.05). Conclusion: Part of the biomaterial was not absorbed and allowed the stability of the evaluated parameters after 5 years, being able to be used as a bone substitute in the socket.
引用
收藏
页数:6
相关论文
共 24 条
[21]   The Effect of Alloplastic Bone Graft and Absorbable Gelatin Sponge in Prevention of Periodontal Defects on the Distal Aspect of Mandibular Second Molars, After Surgical Removal of Impacted Mandibular Third Molar: A Comparative Prospective Study [J].
Singh M. ;
Bhate K. ;
Kulkarni D. ;
Santhosh Kumar S.N. ;
Kathariya R. .
Journal of Maxillofacial and Oral Surgery, 2015, 14 (1) :101-106
[22]   Comparison of cone beam computed tomography imaging with physical measures [J].
Stratemann, S. A. ;
Huang, J. C. ;
Maki, K. ;
Miller, A. J. ;
Hatcher, D. C. .
DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (02) :80-93
[23]   Grafting mandibular third molar extraction sites: A comparison of bioactive glass to a nongrafted site [J].
Throndson, RR ;
Sexton, SB .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2002, 94 (04) :413-419
[24]   Bone density assessments of oral implant sites using computerized tomography [J].
Turkyilmaz, I. ;
Toezuem, T. F. ;
Tumer, C. .
JOURNAL OF ORAL REHABILITATION, 2007, 34 (04) :267-272