Benchmarking Outcomes: Reoperation for Aortic Valve Patient-Prosthesis Mismatch

被引:4
|
作者
Keeling, William B. [1 ]
Beckerman, Ziv [1 ]
Wei, Jane [1 ]
Binongo, Jose [1 ]
Leshnower, Bradley G. [1 ]
Chen, Edward P. [1 ]
机构
[1] Emory Univ, Div Cardiothorac Surg, Dept Surg, Sch Med, 49 Jesse Hill Jr Dr 238-C, Atlanta, GA 30303 USA
关键词
AFFECT SURVIVAL; REPLACEMENT; IMPLANTATION; STENOSIS;
D O I
10.1016/j.athoracsur.2020.07.032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Surgical reoperations for symptomatic aortic valve patient-prosthesis mismatch (PPM) are com-plex. The purpose of this research was to investigate the clinical and echocardiographic outcomes of patients who underwent reoperation for correction of symptomatic PPM after prior aortic valve replacement. Methods. An institutional review identified 60 patients from 2004 to 2018 who underwent reoperative aortic valve replacement for PPM without structural valve degenera-tion. Univariate analyses were conducted to evaluate risk factors for perioperative mortality. Results. Median patient age was 62.8 (interquartile range, 48.3-68.7) years, and mean body mass index was 29.2 +/- 6.6 kg/m2. Thirty-nine (66%) patients underwent a first-time reoperation, and 18 (30.5%) underwent a second-time reoperation. The median interval between initial operation to reoperation for the treatment of PPM was 89 months. Thirty-four (56.7%) patients un-derwent aortic root replacement, while the remainder (43.3%) underwent aortic valve replacement. Additional procedures included replacement of the ascending aorta with or without aortic arch in 26 (43.3%) patients and coronary artery bypass grafting in 7 (12%) patients. Operative mortality and the rates of stroke and renal failure were 5.0%, 3.3%, and 5.0%, respectively. Echo-cardiographic follow-up was available in 64.9% of pa-tients at a mean follow-up of 36.5 months. Preoperative mean pressure gradients were 32.1 +/- 16.0 mm Hg and mean aortic valve area was 0.8 +/- 0.3 cm2, and both improved to 6.6 +/- 4.2 mm Hg and 2.3 +/- 0.7 cm2 (P < .001). Conclusions. Reoperative surgery for PPM is complex but may be performed with good outcomes and low mortality in experienced centers. These data provide excellent clinical and hemodynamic benchmarks for the treatment of PPM in the current era of valve-in-valve transcatheter aortic valve replacement. (C) 2021 by The Society of Thoracic Surgeons
引用
收藏
页码:1472 / 1477
页数:6
相关论文
共 50 条
  • [41] Reconsideration of Patient-Prosthesis Mismatch Definition From the Valve Indexed Effective Orifice Area
    Sakamoto, Yoshimasa
    Yoshitake, Michio
    Naganuma, Hirokuni
    Kawada, Noriyasu
    Kinouchi, Katsushi
    Hashimoto, Kazuhiro
    ANNALS OF THORACIC SURGERY, 2010, 89 (06) : 1951 - 1955
  • [42] Avoiding Patient-Prosthesis Mismatch Is TAVI a New Solution?
    Stewart, William J.
    Rodriguez, L. Leonardo
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (10) : 1063 - 1066
  • [43] Prosthesis-patient mismatch in transcatheter aortic valve replacement
    Grubb, Kendra J.
    Kalra, Kanika
    Tom, Stephanie K.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2025, 72 : 31 - 33
  • [44] Patient-prosthesis mismatch after mitral valve-in-valve procedure - at the cost of life or serious consequence?
    Jagielak, Dariusz
    Kozaryn, Radoslaw
    Jaguszewski, Milosz
    Rogowski, Jan
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2015, 11 (02): : 154 - 155
  • [45] Optimizing Valve Selection in Valve-in-Valve Transcatheter Aortic Valve Replacement: A Case Study on Addressing Patient-Prosthesis Mismatch and Early Structural Valve Deterioration in a Morbidly Obese Patient
    Molina-Lopez, Victor H.
    Ortiz-Cartagena, Ismael
    Mercado-Crespo, Josue
    Campos-Esteve, Miguel A.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [46] Prosthesis-Patient Mismatch After Aortic Valve Replacement: Is It Time for a Redefinition?
    Mannacio, Vito
    De Amicis, Vincenzo
    Vosa, Carlo
    ANNALS OF THORACIC SURGERY, 2014, 97 (04) : 1482 - 1482
  • [48] Moderate Patient-Prosthesis Mismatch Has No Independent Effect on 30-Day Mortality After Isolated Aortic Valve Replacement
    Urso, Stefano
    Sadaba, Rafael
    Monleon-Getino, Toni
    Aldamiz-Echevarria, Gonzalo
    REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (04): : 409 - 414
  • [49] Impact of Pre-Existing Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures
    Pibarot, Philippe
    Simonato, Matheus
    Barbanti, Marco
    Linke, Axel
    Kornowski, Ran
    Rudolph, Tanja
    Spence, Mark
    Moat, Neil
    Aldea, Gabriel
    Mennuni, Marco
    Iadanza, Alessandro
    Amrane, Hafid
    Gaia, Diego
    Kim, Won-Keun
    Napodano, Massimo
    Baumbach, Hardy
    Finkelstein, Ariel
    Kobayashi, Junjiro
    Brecker, Stephen
    Don, Creighton
    Cerillo, Alfredo
    Unbehaun, Axel
    Attias, David
    Nejjari, Mohammed
    Jones, Noah
    Fiorina, Claudia
    Tchetche, Didier
    Philippart, Raphael
    Spargias, Konstantinos
    Hernandez, Jose-Maria
    Latib, Azeem
    Dvir, Danny
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (02) : 133 - 141
  • [50] Aortic root enlargement versus stentless valve implantation for avoidance of patient-prosthesis mismatch in patients with small aortic root: protocol for a systematic review
    Meneas, Christophe
    Voisine, Pierre
    Mestres, Carlos
    Sall, Fatouma
    Kabore, Remi
    N'guessan, Anon
    Yangni-Angate, Herve
    Mohammadi, Siamak
    Dagenais, Francois
    BMJ OPEN, 2024, 14 (08): : 1 - 4