Benchmarking Outcomes: Reoperation for Aortic Valve Patient-Prosthesis Mismatch

被引:4
|
作者
Keeling, William B. [1 ]
Beckerman, Ziv [1 ]
Wei, Jane [1 ]
Binongo, Jose [1 ]
Leshnower, Bradley G. [1 ]
Chen, Edward P. [1 ]
机构
[1] Emory Univ, Div Cardiothorac Surg, Dept Surg, Sch Med, 49 Jesse Hill Jr Dr 238-C, Atlanta, GA 30303 USA
关键词
AFFECT SURVIVAL; REPLACEMENT; IMPLANTATION; STENOSIS;
D O I
10.1016/j.athoracsur.2020.07.032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Surgical reoperations for symptomatic aortic valve patient-prosthesis mismatch (PPM) are com-plex. The purpose of this research was to investigate the clinical and echocardiographic outcomes of patients who underwent reoperation for correction of symptomatic PPM after prior aortic valve replacement. Methods. An institutional review identified 60 patients from 2004 to 2018 who underwent reoperative aortic valve replacement for PPM without structural valve degenera-tion. Univariate analyses were conducted to evaluate risk factors for perioperative mortality. Results. Median patient age was 62.8 (interquartile range, 48.3-68.7) years, and mean body mass index was 29.2 +/- 6.6 kg/m2. Thirty-nine (66%) patients underwent a first-time reoperation, and 18 (30.5%) underwent a second-time reoperation. The median interval between initial operation to reoperation for the treatment of PPM was 89 months. Thirty-four (56.7%) patients un-derwent aortic root replacement, while the remainder (43.3%) underwent aortic valve replacement. Additional procedures included replacement of the ascending aorta with or without aortic arch in 26 (43.3%) patients and coronary artery bypass grafting in 7 (12%) patients. Operative mortality and the rates of stroke and renal failure were 5.0%, 3.3%, and 5.0%, respectively. Echo-cardiographic follow-up was available in 64.9% of pa-tients at a mean follow-up of 36.5 months. Preoperative mean pressure gradients were 32.1 +/- 16.0 mm Hg and mean aortic valve area was 0.8 +/- 0.3 cm2, and both improved to 6.6 +/- 4.2 mm Hg and 2.3 +/- 0.7 cm2 (P < .001). Conclusions. Reoperative surgery for PPM is complex but may be performed with good outcomes and low mortality in experienced centers. These data provide excellent clinical and hemodynamic benchmarks for the treatment of PPM in the current era of valve-in-valve transcatheter aortic valve replacement. (C) 2021 by The Society of Thoracic Surgeons
引用
收藏
页码:1472 / 1477
页数:6
相关论文
共 50 条
  • [31] A Retrospective Analysis of Standardized Gradient Calculations for Evaluating Patient-Prosthesis Mismatch Following Mechanical Aortic Valve Replacement
    Saglam, Muhammet Fethi
    Uguz, Emrah
    Erdogan, Kemal Esref
    Ercelik, Huseyin unsal
    Yucel, Murat
    Alili, Altay
    Elipek, Nur Gizem
    Karaca, Okay Guven
    Sener, Erol
    DIAGNOSTICS, 2025, 15 (05)
  • [32] Aortic Root Enlargement Is Safe and Reduces the Incidence of Patient-Prosthesis Mismatch: A Meta-analysis of Early and Late Outcomes
    Yu, Wanqing
    Tam, Derrick Y.
    Rocha, Rodolfo V.
    Makhdoum, Ahmad
    Ouzounian, Maral
    Fremes, Stephen E.
    CANADIAN JOURNAL OF CARDIOLOGY, 2019, 35 (06) : 782 - 790
  • [33] Valve-in-valve TAVR using the SAPIEN 3 transcatheter heart valve: still plagued by patient-prosthesis mismatch
    Saxon, John T.
    Cohen, David J.
    Feldman, Ted
    EUROINTERVENTION, 2018, 14 (04) : E377 - E379
  • [34] Aortoventriculoplasty for Correction of Patient-Prosthesis Mismatch Examples
    Vural, Kerem M.
    Ozyalcin, Sertan
    Turkmen, Ufuk
    Bozkurt, Tezcan
    HEART LUNG AND CIRCULATION, 2014, 23 (03) : E96 - E99
  • [35] Prosthesis-patient mismatch after transcatheter aortic valve implantation
    Leone, Pier Pasquale
    Pagnesi, Matteo
    Regazzoli, Damiano
    Latib, Azeem
    GIORNALE ITALIANO DI CARDIOLOGIA, 2020, 21 (11) : 26S - 34S
  • [36] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
    Takagi, Hisato
    Umemoto, Takuya
    ANNALS OF THORACIC SURGERY, 2016, 101 (03) : 872 - 880
  • [37] Patient-prosthesis mismatch in patients treated with transcatheter aortic valve implantation - predictors, incidence and impact on clinical efficacy. A preliminary study
    Zbronski, Karol
    Rymuza, Bartosz
    Scislo, Piotr
    Grodecki, Kajetan
    Dobkowska, Paulina
    Wawrzacz, Marek
    Wilimski, Radoslaw
    Slowikowska, Anna
    Kochman, Janusz
    Filipiak, Krzysztof J.
    Opolski, Grzegorz
    Huczek, Zenon
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2017, 13 (04): : 281 - 287
  • [38] Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era
    Tuzcu, E. Murat
    Oezkan, Alper
    Kapadia, Samir R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1919 - 1922
  • [39] The effect of patient-prosthesis mismatch on survival after aortic and mitral valve replacement: a 10 year, single institution experience
    Das De, Sudeep
    Nanjappa, Ashok
    Morcos, Karim
    Aftab, Sadia
    Butler, John
    Pathi, Vivek
    Curry, Philip
    Nair, Sukumaran
    JOURNAL OF CARDIOTHORACIC SURGERY, 2019, 14 (01)
  • [40] Comprehensive Hemodynamic Performance and Frequency of Patient-Prosthesis Mismatch of the St. Jude Medical Trifecta™ Bioprosthetic Aortic Valve
    Yadlapati, Ajay
    Diep, Jimmy
    Barnes, Mary-Jo
    Grogan, Tristan
    Bethencourt, Daniel M.
    Vorobiof, Gabriel
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (04) : 516 - 523