Benchmarking Outcomes: Reoperation for Aortic Valve Patient-Prosthesis Mismatch

被引:4
|
作者
Keeling, William B. [1 ]
Beckerman, Ziv [1 ]
Wei, Jane [1 ]
Binongo, Jose [1 ]
Leshnower, Bradley G. [1 ]
Chen, Edward P. [1 ]
机构
[1] Emory Univ, Div Cardiothorac Surg, Dept Surg, Sch Med, 49 Jesse Hill Jr Dr 238-C, Atlanta, GA 30303 USA
关键词
AFFECT SURVIVAL; REPLACEMENT; IMPLANTATION; STENOSIS;
D O I
10.1016/j.athoracsur.2020.07.032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Surgical reoperations for symptomatic aortic valve patient-prosthesis mismatch (PPM) are com-plex. The purpose of this research was to investigate the clinical and echocardiographic outcomes of patients who underwent reoperation for correction of symptomatic PPM after prior aortic valve replacement. Methods. An institutional review identified 60 patients from 2004 to 2018 who underwent reoperative aortic valve replacement for PPM without structural valve degenera-tion. Univariate analyses were conducted to evaluate risk factors for perioperative mortality. Results. Median patient age was 62.8 (interquartile range, 48.3-68.7) years, and mean body mass index was 29.2 +/- 6.6 kg/m2. Thirty-nine (66%) patients underwent a first-time reoperation, and 18 (30.5%) underwent a second-time reoperation. The median interval between initial operation to reoperation for the treatment of PPM was 89 months. Thirty-four (56.7%) patients un-derwent aortic root replacement, while the remainder (43.3%) underwent aortic valve replacement. Additional procedures included replacement of the ascending aorta with or without aortic arch in 26 (43.3%) patients and coronary artery bypass grafting in 7 (12%) patients. Operative mortality and the rates of stroke and renal failure were 5.0%, 3.3%, and 5.0%, respectively. Echo-cardiographic follow-up was available in 64.9% of pa-tients at a mean follow-up of 36.5 months. Preoperative mean pressure gradients were 32.1 +/- 16.0 mm Hg and mean aortic valve area was 0.8 +/- 0.3 cm2, and both improved to 6.6 +/- 4.2 mm Hg and 2.3 +/- 0.7 cm2 (P < .001). Conclusions. Reoperative surgery for PPM is complex but may be performed with good outcomes and low mortality in experienced centers. These data provide excellent clinical and hemodynamic benchmarks for the treatment of PPM in the current era of valve-in-valve transcatheter aortic valve replacement. (C) 2021 by The Society of Thoracic Surgeons
引用
收藏
页码:1472 / 1477
页数:6
相关论文
共 50 条
  • [1] Patient-prosthesis mismatch following aortic valve replacement
    Bilkhu, Rajdeep
    Jahangiri, Marjan
    Otto, Catherine M.
    HEART, 2019, 105 : S28 - S33
  • [2] Surgical versus transcatheter aortic valve replacement: Impact of patient-prosthesis mismatch on outcomes
    Alnajar, Ahmed
    Hamad, Naser
    Azhar, Muhammad Z.
    Mousa, Yaseen
    Arora, Yingyot
    Lamelas, Joseph
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 5388 - 5394
  • [3] Predictors and outcomes of patient-prosthesis mismatch after transcatheter aortic valve replacement
    Stamou, Sotiris C.
    Chen, Kai
    James, Taylor M.
    Rothenberg, Mark
    Kapila, Arvind
    Faber, Cristiano
    Nores, Marcos A.
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (02) : 360 - 366
  • [4] Patient-prosthesis mismatch increases the mean platelet volume in patients with aortic valve replacement
    Bayram, Huseyin
    Hidiroglu, Mete
    Cetin, Levent
    Cicek, Omer Faruk
    Kucuker, Aslihan
    Uguz, Emrah
    Erdogan, Kemal Esref
    Sener, Erol
    SURGERY TODAY, 2015, 45 (05) : 559 - 563
  • [5] Patient-Prosthesis Mismatch in Patients Undergoing Bioprosthetic Aortic Valve Implantation Increases Risk of Reoperation for Structural Valve Deterioration
    Urso, Stefano
    Calderon, Pilar
    Sadaba, Rafael
    Mahillo, Ignacio
    Tunon, Jose
    Aldamiz, Gonzalo
    Fraile, Julian
    JOURNAL OF CARDIAC SURGERY, 2014, 29 (04) : 439 - 444
  • [6] Predicting patient-prosthesis mismatch by aortic root evaluation before aortic valve replacement
    Maeda, Koichi
    Kuratani, Toru
    Yoshioka, Daisuke
    Pak, Kyongsun
    Shimamura, Kazuo
    Toda, Koichi
    Sawa, Yoshiki
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 158 (01) : 61 - +
  • [7] Patient-prosthesis mismatch after minimally invasive aortic valve replacement
    Filip, Grzegorz
    Litwinowicz, Radoslaw
    Kapelak, Boguslaw
    Bryndza, Magdalena
    Bartus, Magdalena
    Konstanty-Kalandyk, Janusz
    Ceranowicz, Piotr
    Brzezinski, Maciej
    Gafoor, Sameer
    Bartus, Krzysztof
    KARDIOLOGIA POLSKA, 2018, 76 (05) : 908 - 910
  • [8] Patient-prosthesis mismatch after transapical aortic valve implantation: Incidence and impact on survival
    Kukucka, Marian
    Pasic, Miralem
    Dreysse, Stephan
    Mladenow, Alexander
    Habazettl, Helmut
    Hetzer, Roland
    Unbehaun, Axel
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (02) : 391 - 397
  • [9] Factors Determining Patient-Prosthesis Mismatch after Aortic Valve Replacement - A Prospective Cohort Study
    Bonderman, Diana
    Graf, Alexandra
    Kammerlander, Andreas A.
    Kocher, Alfred
    Laufer, Guenter
    Lang, Irene M.
    Mascherbauer, Julia
    PLOS ONE, 2013, 8 (12):
  • [10] Patient-Prosthesis Mismatch After Aortic Valve Intervention Another Win for Transcatheter Aortic Valve Replacement
    Prendergast, Bernard D.
    McConkey, Hannah Z. R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (08) : 781 - 783