Benchmarking Outcomes: Reoperation for Aortic Valve Patient-Prosthesis Mismatch

被引:4
作者
Keeling, William B. [1 ]
Beckerman, Ziv [1 ]
Wei, Jane [1 ]
Binongo, Jose [1 ]
Leshnower, Bradley G. [1 ]
Chen, Edward P. [1 ]
机构
[1] Emory Univ, Div Cardiothorac Surg, Dept Surg, Sch Med, 49 Jesse Hill Jr Dr 238-C, Atlanta, GA 30303 USA
关键词
AFFECT SURVIVAL; REPLACEMENT; IMPLANTATION; STENOSIS;
D O I
10.1016/j.athoracsur.2020.07.032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Surgical reoperations for symptomatic aortic valve patient-prosthesis mismatch (PPM) are com-plex. The purpose of this research was to investigate the clinical and echocardiographic outcomes of patients who underwent reoperation for correction of symptomatic PPM after prior aortic valve replacement. Methods. An institutional review identified 60 patients from 2004 to 2018 who underwent reoperative aortic valve replacement for PPM without structural valve degenera-tion. Univariate analyses were conducted to evaluate risk factors for perioperative mortality. Results. Median patient age was 62.8 (interquartile range, 48.3-68.7) years, and mean body mass index was 29.2 +/- 6.6 kg/m2. Thirty-nine (66%) patients underwent a first-time reoperation, and 18 (30.5%) underwent a second-time reoperation. The median interval between initial operation to reoperation for the treatment of PPM was 89 months. Thirty-four (56.7%) patients un-derwent aortic root replacement, while the remainder (43.3%) underwent aortic valve replacement. Additional procedures included replacement of the ascending aorta with or without aortic arch in 26 (43.3%) patients and coronary artery bypass grafting in 7 (12%) patients. Operative mortality and the rates of stroke and renal failure were 5.0%, 3.3%, and 5.0%, respectively. Echo-cardiographic follow-up was available in 64.9% of pa-tients at a mean follow-up of 36.5 months. Preoperative mean pressure gradients were 32.1 +/- 16.0 mm Hg and mean aortic valve area was 0.8 +/- 0.3 cm2, and both improved to 6.6 +/- 4.2 mm Hg and 2.3 +/- 0.7 cm2 (P < .001). Conclusions. Reoperative surgery for PPM is complex but may be performed with good outcomes and low mortality in experienced centers. These data provide excellent clinical and hemodynamic benchmarks for the treatment of PPM in the current era of valve-in-valve transcatheter aortic valve replacement. (C) 2021 by The Society of Thoracic Surgeons
引用
收藏
页码:1472 / 1477
页数:6
相关论文
共 14 条
[1]   Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method? [J].
Bleiziffer, Sabine ;
Eichinger, Walter B. ;
Hettich, Ina ;
Guenzinger, Ralf ;
Ruzicka, Daniel ;
Bauernschmitt, Robert ;
Lange, Ruediger .
HEART, 2007, 93 (05) :615-620
[2]   Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves [J].
Dvir, Danny ;
Webb, John G. ;
Bleiziffer, Sabine ;
Pasic, Miralem ;
Waksman, Ron ;
Kodali, Susheel ;
Barbanti, Marco ;
Latib, Azeem ;
Schaefer, Ulrich ;
Rodes-Cabau, Josep ;
Treede, Hendrik ;
Piazza, Nicolo ;
Hildick-Smith, David ;
Himbert, Dominique ;
Walther, Thomas ;
Hengstenberg, Christian ;
Nissen, Henrik ;
Bekeredjian, Raffi ;
Presbitero, Patrizia ;
Ferrari, Enrico ;
Segev, Amit ;
de Weger, Arend ;
Windecker, Stephan ;
Moat, Neil E. ;
Napodano, Massimo ;
Wilbring, Manuel ;
Cerillo, Alfredo G. ;
Brecker, Stephen ;
Tchetche, Didier ;
Lefevre, Thierry ;
De Marco, Federico ;
Fiorina, Claudia ;
Petronio, Anna Sonia ;
Teles, Rui C. ;
Testa, Luca ;
Laborde, Jean-Claude ;
Leon, Martin B. ;
Kornowski, Ran .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (02) :162-170
[3]   The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement [J].
Fallon, John M. ;
DeSimone, Joseph P. ;
Brennan, J. Matthew ;
O'Brien, Sean ;
Thibault, Dylan P. ;
DiScipio, Anthony W. ;
Pibarot, Philippe ;
Jacobs, Jeffrey P. ;
Malenka, David J. ;
Clarizia, Nadia A. ;
Ruel, Marc .
ANNALS OF THORACIC SURGERY, 2018, 106 (01) :14-23
[4]   Patient-prosthesis mismatch in aortic valve replacement:: really tolerable? [J].
Fuster, RG ;
Argudo, JAM ;
Albarova, OG ;
Sos, FH ;
López, SC ;
Codoñer, MB ;
Miñano, JAB ;
Albarran, IR .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (03) :441-449
[5]   Prosthesis-Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement From the STS/ACC TVT Registry [J].
Herrmann, Howard C. ;
Daneshvar, Samuel A. ;
Fonarow, Gregg C. ;
Stebbins, Amanda ;
Vemulapalli, Sreekanth ;
Desai, Nimesh D. ;
Malenka, David J. ;
Thourani, Vinod H. ;
Rymer, Jennifer ;
Kosinski, Andrzej S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) :2701-2711
[6]   Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: A prospective observational study [J].
Hong, Soonchang ;
Yi, Gijong ;
Youn, Young-Nam ;
Lee, Sak ;
Yoo, Kyung-Jong ;
Chang, Byung-Chul .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (05) :1098-1104
[7]   Patient-prosthesis mismatch does not affect survival following aortic valve replacement [J].
Howell, Neil J. ;
Keogh, Bruce E. ;
Barnet, Vivien ;
Bonser, Robert S. ;
Graham, Timothy R. ;
Rooney, Stephen J. ;
Wilson, Ian C. ;
Pagano, Domenico .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (01) :10-14
[8]   Patient-Prosthesis Mismatch in Patients With Aortic Stenosis Undergoing Isolated Aortic Valve Replacement Does Not Affect Survival [J].
Howell, Neil J. ;
Keogh, Bruce E. ;
Ray, Daniel ;
Bonser, Robert S. ;
Graham, Tim R. ;
Mascaro, Jorge ;
Rooney, Stephen J. ;
Wilson, Ian C. ;
Pagano, Domenico .
ANNALS OF THORACIC SURGERY, 2010, 89 (01) :60-64
[9]   Re-operation for bioprosthetic aortic structural failure - risk assessment [J].
Jamieson, WRE ;
Burr, LH ;
Miyagishima, RT ;
Janusz, MT ;
Fradet, GJ ;
Ling, H ;
Lichtenstein, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 24 (06) :873-878
[10]   PROBLEM OF VALVE PROSTHESIS PATIENT MISMATCH [J].
RAHIMTOOLA, SH .
CIRCULATION, 1978, 58 (01) :20-24