Towards Partial Discharge Automatic and Unsupervised Monitoring: A Technological Breakthrough for MV Electrical Asset Condition Monitoring and Diagnostics

被引:0
作者
Montanari, G. C. [1 ]
Schwartz, S. [1 ,2 ]
Yang, Q. [1 ]
Nath, D. [1 ]
Ghosh, R. [1 ]
Cuzner, R. [2 ]
机构
[1] CAPS Florida State Univ, Tallahassee, FL 32306 USA
[2] Univ Wisconsin, Milwaukee, WI 53201 USA
来源
2022 9TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD) | 2022年
关键词
Partial Discharge; Separation; Recognition; Identification; Automatic Unsupervised Software; MV Electrical Assets; INSULATION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Medium Voltage (MV) electrical assets are no longer just distribution networks, since also electrified transportation is moving towards kV, if not tens on kV, of target operating voltage and renewable power generation, being largely distributed, is also often delivered through MV links. A characteristic aspect of the evolution of MV assets is the type of power supply, which is moving towards a hybrid concept: voltage can be DC or modulated AC, that includes voltage transients, ripple, and harmonics. As regards insulation systems, however, this trend can be fatal for life and reliability, since the type of stress to be withstood, mostly electrical and thermal (but also mechanical and environmental, for example in aerospace or electric vehicles), could be far beyond the reference used for decades for the design of electrical insulation, which has been based on AC sinusoidal electrical stress. The implication is that even good and conservative design could not work anymore to avoid premature breakdown, due both intrinsic and, especially, extrinsic accelerated aging. Hence, besides relying upon the best available design practice, monitoring the health conditions of MV asset components is becoming crucial to get grid/asset working effectively for the whole planned operation life. However, measuring/monitoring diagnostic quantities often relies upon expert interpretation of diagnostic monitoring results, which for matters of cost, data amount and timing, is not feasible for MV assets on a large scale. This paper has the purpose to discuss the feasibility of an innovative, automatic approach to PD monitoring which has the potentiality to allow MV asset components to self-diagnose their health conditions and interact smartly with asset and maintenance managers. The fundamentals of the algorithms developed for such a smart component and examples of its application on electrical and electronics asset components ( as PCB and spacers) are presented in the paper.
引用
收藏
页码:588 / 592
页数:5
相关论文
共 31 条
  • [21] Partial Discharge Measurement and Condition Monitoring in Power-electronics Controlled Rotating Machines: Issues and Solutions in Advanced Electrified Transport and Aerospace Applications
    Ghosh, Riddhi
    Montanari, Gian Carlo
    Seri, Paolo
    2020 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD 2020), 2020, : 358 - 363
  • [22] An Unsupervised Approach to Partial Discharge Monitoring in Rotating Machines: Detection to Diagnosis With Reduced Need of Expert Support
    Seri, Paolo
    Ghosh, Riddhi
    Montanari, Gian Carlo
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2021, 36 (03) : 2485 - 2492
  • [23] Microstrip Patch Antenna for Partial Discharge Detection as a Condition Monitoring Tool of Power System Assets
    Ediriweera, W. E. P. S.
    Priyanayana, K. S.
    Rajakaruna, R. M. A. P.
    Ranasinghe, R. A. K. G.
    Lucas, J. R.
    Samarasinghe, R.
    2017 3RD INTERNATIONAL MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON), 2017, : 368 - 372
  • [24] ON-LINE PARTIAL DISCHARGE INSULATION CONDITION MONITORING OF COMPLETE HIGH VOLTAGE (HV) NETWORKS
    Renforth, Lee
    Giussani, Riccardo
    Mendiola, Michael T.
    Dodd, Lewis
    2017 INDUSTRY APPLICATIONS SOCIETY 64TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE (PCIC), 2017, : 103 - 111
  • [25] A Perspective on Online Partial Discharge Monitoring for Assessment of the Condition of Rotating Machine Stator Winding Insulation
    Stone, G. C.
    IEEE ELECTRICAL INSULATION MAGAZINE, 2012, 28 (05) : 8 - 13
  • [26] Partial Discharge Location using Unsynchronized Radiometer Network for Condition Monitoring in HV Substations - A Proposed Approach
    de Souza Neto, J. M. R.
    de Macedo, E. C. T.
    da Rocha Neto, J. S.
    da Costa, E. G.
    Bhatti, S. A.
    Glover, I. A.
    25TH INTERNATIONAL CONGRESS ON CONDITION MONITORING AND DIAGNOSTIC ENGINEERING (COMADEM 2012), 2012, 364
  • [27] Simple statistical approach presenting Partial Discharge data in large pool of MV motors in continuous and remote PD monitoring system
    Blokhintsev, Igor
    Kozusko, Jim
    Oberer, Brian
    Anzaldi, David
    2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 339 - 343
  • [28] Summary of industry practices, guides and standards related to on-line partial discharge monitoring of stator insulation condition
    Green, V
    Sasic, M
    Wright, B
    INDUSTRY APPLICATIONS SOCIETY 52ND ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2005, : 359 - 365
  • [29] Partial Discharge measurements in Electrical Machines controlled by Variable Speed Drives: from Design Validation to permanent PD Monitoring
    Fornasari, Luca
    Caprara, Andrea
    Montanari, Gian Carlo
    2013 9TH IEEE INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2013, : 384 - 390
  • [30] A method for monitoring partial discharge of electrical cable based on magneto-optic crystal optical fiber current sensor
    Zheng, Haiming
    Fang, Bin
    Yao, Penghui
    Hao, Peng
    Yao, X. Steve
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS X, 2020, 11554