A laser probe coupled with ICP-double-focusing sector-field mass spectrometer for in situ analysis of geological samples and U-Pb dating of zircon

被引:139
|
作者
Tiepolo, M
Bottazzi, P
Palenzona, M
Vannucci, R
机构
[1] CNR, Ist Geosci & Georisorse, Sez Pavia, I-27100 Pavia, Italy
[2] Univ Pavia, Dipartimento Sci Terra, I-27100 Pavia, Italy
关键词
laser ablation; ICP-MS; double-focusing sector-field mass spectrometer; precision; accuracy; trace elements; U-Pb; zircon dating;
D O I
10.2113/gscanmin.41.2.259
中图分类号
P57 [矿物学];
学科分类号
070901 ;
摘要
Quadrupole ICP-MS is currently the method of choice for laser-ablation applications, since sector-field instruments are generally considered too slow for the acquisition of rapidly varying signals. However, the new generation of double-focusing sector-field mass spectrometers is capable of rapidly scanning the mass spectrum both magnetically and electrostatically, and the combination of these two scan modes approaches the performance of quadrupoles for most practical applications. We present the instrumental configuration and operating conditions of a LA-ICP-MS system, assembled by coupling a 266 nm laser source to a double-focusing magnetic-sector mass spectrometer ("Element", Finnigan MAT). The capability of the adopted Configuration to furnish hi.-h-quality ill situ trace-element analysis of minerals and U-Pb geochronological data is described. Concentrations of thirty geochemically relevant elements (LILE, HFSE, REE, actinides) were determined on geological samples with good precision and accuracy (<10%), evaluated using two USGS basaltic glass reference materials, BCR-2 and BIR-1. The high sensitivity and low background allowed extremely low limits of detection (down to the ppb level) for the heaviest elements, and between 10 and 100 ppb for the lighter masses. The first results on U:Pb ratio determinations are also very positive. By adopting an external matrix-matched standard for corrections of mass bias and laser-induced fractionation of elements, precision and accuracy in age determinations to better than similar to2% are attained on the zircon standard 91500.
引用
收藏
页码:259 / 272
页数:14
相关论文
共 17 条
  • [1] Multielement analysis of petroleum samples by laser ablation double focusing sector field inductively coupled plasma mass spectrometry (LA-ICP MS)
    Vorapalawut, Nopparat
    Pohl, Pawel
    Bouyssiere, Brice
    Shiowatana, Juwadee
    Lobinski, Ryszard
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) : 618 - 622
  • [2] Zircon fission-track and U-Pb double dating using femtosecond laser ablation-inductively coupled plasma-mass spectrometry: A technical note
    Iwano, Hideki
    Danhara, Tohru
    Danhara, Yugo
    Hirabayashi, Saori
    Nakajima, Toru
    Sakai, Harutaka
    Hirata, Takafumi
    ISLAND ARC, 2020, 29 (01) : 1 - 10
  • [3] In situ petrographic thin section U-Pb dating of zircon, monazite, and titanite using laser ablation-MC-ICP-MS
    Simonetti, A
    Heaman, LM
    Chacko, T
    Banerjee, NR
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 253 (1-2) : 87 - 97
  • [4] U-Pb dating of zircons from PZ3-MZ igneous complexes of Transbaikalia by sector-field mass spectrometry with laser sampling: technique and comparison with SHRIMP
    Khubanov, V. B.
    Buyantuev, M. D.
    Tsygankov, A. A.
    RUSSIAN GEOLOGY AND GEOPHYSICS, 2016, 57 (01) : 190 - 205
  • [5] Evaluation of Pb-Pb and U-Pb laser ablation ICP-MS zircon dating using matrix-matched calibration samples with a frequency quadrupled (266 nm) Nd-YAG laser
    Bruguier, O
    Télouk, P
    Cocherie, A
    Fouillac, AM
    Albarède, F
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2001, 25 (2-3): : 361 - 373
  • [6] Multi-element analysis of bread, cheese, fruit and vegetables by double-focusing sector-field inductively coupled plasma mass spectrometry
    Khouzam, Rola Bou
    Lobinski, Ryszard
    Pohl, Pawel
    ANALYTICAL METHODS, 2011, 3 (09) : 2115 - 2120
  • [7] In situ Pb geochronology of zircon with laser ablation-inductively coupled plasma-sector field mass spectrometry
    Tiepolo, M
    CHEMICAL GEOLOGY, 2003, 199 (1-2) : 159 - 177
  • [8] Spot zircon U-Pb isotope analysis by ICP-MS coupled with a frequency quintupled (213 nm) Nd-YAG laser system
    Xia, XP
    Sun, M
    Zhao, GC
    Li, HM
    Zhou, MF
    GEOCHEMICAL JOURNAL, 2004, 38 (02) : 191 - 200
  • [9] Micro-analytical zircon and monazite U-Pb isotope dating by laser ablation-inductively coupled plasma-quadrupole mass spectrometry
    Alagna, Keegan E.
    Petrelli, Maurizio
    Perugini, Diego
    Poli, Giampiero
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2008, 32 (01) : 103 - 120
  • [10] High spatial resolution in situ U-Pb dating using laser ablation multiple ion counting inductively coupled plasma mass spectrometry (LA-MIC-ICP-MS)
    Xie, Lie-Wen
    Yang, Jin-Hui
    Yin, Qing-Zhu
    Yang, Yue-Heng
    Liu, Jing-Bo
    Huang, Chao
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (05) : 975 - 986