Protein deposition from dry powder inhalers: Fine particle multiplets as performance modifiers

被引:132
|
作者
Lucas, P [1 ]
Anderson, K [1 ]
Staniforth, JN [1 ]
机构
[1] Univ Bath, Dept Pharm & Pharmacol, Bath BA2 7AY, Avon, England
关键词
dry powder aerosol; inhalation; protein; mixing; ternary component; polyethylene glycol;
D O I
10.1023/A:1011977826711
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose. To evaluate the use of carrier-based dry powder aerosols for inhalation delivery of proteins and examine the effect of fine particle excipients as potential formulation performance modifiers. Methods. Bovine serum albumin (BSA) was co-processed with maltodextrin by spray-drying to produce model protein particles. Aerosol formulations were prepared by tumble mixing protein powders with alpha-lactose monohydrate (63-90 mu m) or modified lactoses containing between 2.5 and 10% w/w fine particle lactose (FPL) or micronised polyethylene glycol 6000. Powder blends were characterised in terms of particle size distribution, morphology and powder flow. Formulation performance in Diskhaler(R) and Rotahaler(R) devices was investigated using a twin stage impinger operating at 60 l min(-1). Results. Inhalation performance of binary ordered mixes prepared using BSA-maltodextrin and lactose (63-90 mu m) was improved by addition of FPL and micronised PEG 6000. For the addition of 5% w/w FPL the protein fine particle fraction (0.5-6.4 mu m) using the Diskhaler(R) was increased from 31.7 +/- 2.4% to 47.4 +/- 2.2%. Inclusion of FPL and micronised PEG 6000 changed the bulk properties of inhalation powders and reduced powder flow but did not affect device emptying. Unexpectedly, Improvements in performance were found to be independent of the order of addition of FPL to the ternary powder formulations. SEM studies revealed that this was probably the result of a redistribution of protein particles between the coarse carrier lactose component and added FPL during mixing. Conclusions. Fine particle excipients can be used to improve the performance of carrier-based protein dry powder aerosols. Mechanistically, enhancement of performance is proposed to result from a redistribution of protein particles from coarse carrier particles to the fine particle component in the ternary mix.
引用
收藏
页码:562 / 569
页数:8
相关论文
共 50 条
  • [1] Protein Deposition from Dry Powder Inhalers: Fine Particle Multiplets as Performance Modifiers
    Paul Lucas
    Kerry Anderson
    John N. Staniforth
    Pharmaceutical Research, 1998, 15 : 562 - 569
  • [2] Predicting extrathoracic deposition from dry powder inhalers
    DeHaan, WH
    Finlay, WH
    JOURNAL OF AEROSOL SCIENCE, 2004, 35 (03) : 309 - 331
  • [3] Predicting extrathoracic deposition from dry powder inhalers
    Finlay, W.H. (warren.finlay@ualberta.ca), 1600, Elsevier Ltd (35):
  • [4] Are extra-fine particles from dry powder inhalers likely to improve lung deposition?
    Gjaltema, Doetie
    Hagedoorn, Paul
    Frijlink, Henderik
    de Boer, Anne H.
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [5] Variability of fine particle dose and lung deposition of budesonide delivered through two multidose dry powder inhalers
    Munzel, U
    Marschall, K
    Fyrnys, B
    Wedel, M
    CURRENT MEDICAL RESEARCH AND OPINION, 2005, 21 (06) : 827 - 833
  • [6] INVESTIGATING POWDER FLUIDISATION AND PARTICLE ENTRAINMENT FROM DRY POWDER INHALERS
    Vernall, C.
    Tibbatts, J.
    Stephens, T.
    Murphy, S. D.
    Price, R.
    Shur, J.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (04) : A256 - A256
  • [7] AN INVITRO METHOD FOR ASSESSING PARTICLE DEPOSITION FROM METERED PRESSURISED AEROSOLS AND DRY POWDER INHALERS
    MARTIN, GP
    BELL, AE
    MARRIOTT, C
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1988, 44 (1-3) : 57 - 63
  • [8] Predicting the Fine Particle Fraction of Dry Powder Inhalers Using Artificial Neural Networks
    Muddle, Joanna
    Kirton, Stewart B.
    Parisini, Irene
    Muddle, Andrew
    Murnane, Darragh
    Ali, Jogoth
    Brown, Marc
    Page, Clive
    Forbes, Ben
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 106 (01) : 313 - 321
  • [9] Scintigraphic comparison of budesonide deposition from two dry powder inhalers
    Newman, SP
    Pitcairn, GR
    Hirst, PH
    Bacon, RE
    O'Keefe, E
    Reiners, M
    Hermann, R
    EUROPEAN RESPIRATORY JOURNAL, 2000, 16 (01) : 178 - 183
  • [10] Non-dimensional functional relationship for the fine particle fraction produced by dry powder inhalers
    Mendes, P. J.
    Pinto, J. F.
    Sousa, J. M. M.
    JOURNAL OF AEROSOL SCIENCE, 2007, 38 (06) : 612 - 624