Determination of environmental estrogens and bisphenol A in water samples by ultra-high performance liquid chromatography coupled to Q-Exactive high resolution mass spectrometry after magnetic solid-phase extraction

被引:27
作者
Zhao, Yan [1 ,3 ,4 ]
Bai, Xiao-Lin [1 ]
Song, Tao [4 ]
Zhang, Guo-Lin [1 ]
Yuan, Yun-Cong [1 ,3 ]
Liu, Yi-Ming [1 ,2 ]
Liao, Xun [1 ]
机构
[1] Chinese Acad Sci, Chengdu Inst Biol, Chengdu 610041, Sichuan, Peoples R China
[2] Jackson State Univ, Dept Chem & Biochem, Jackson, MS 39217 USA
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Sichuan Willtest Technol Co Ltd, Chengdu 610041, Sichuan, Peoples R China
关键词
Water; Environmental estrogens; Bisphenol A; Fe3O4@nSiO(2)@mSiO(2)-CHO-MNPs; Magnetic solid phase extraction; UHPLC-Q-Exactive HRMS; ENDOCRINE-DISRUPTING CHEMICALS; SORPTIVE EXTRACTION; TRACE ANALYSIS; SURFACE-WATER; MICROSPHERES; NANOPARTICLES; REMOVAL; SHELL; CORE; GLUCOCORTICOIDS;
D O I
10.1016/j.microc.2019.104212
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel, simple and rapid method based on the magnetic solid-phase extraction (MSPE) combined with ultra-high performance liquid chromatography coupled to Q-Exactive high resolution mass spectrometry (UHPLC-Q-Exactive HRMS) was developed for the determination of bisphenol A, 17 beta-estradiol, dienestrol, hexestrol, and diethylstilbestrol in water samples. In this study, novel aldehyde group functionalized core-shell mesoporous silica magnetic nanoparticles were used as adsorbents for purification and enrichment of the environmental estrogens and bisphenol A for the first time. The main factors including desorption solvent, adsorbent amount, adsorption time and desorption time affecting the performance of MSPE procedure were investigated in detail. Linearities with determination coefficients higher than 0.998 were obtained for all the target compounds, and the mean recoveries were in the range of 81.7-96.3%. The intra-day and inter-day precision were satisfactory with the relative standard deviations in the range of 2.3-8.1% and 3.5-9.9%, respectively. The limits of detection were found between 0.2 and 3.0 ng/L. Finally, the developed MSPE-UHPLC-Q-Exactive HRMS method was successfully applied for determination of the environmental estrogens and bisphenol A in water samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Simultaneous determination of 61 hormones in water by solid phase extraction-ultra performance liquid chromatography-tandem mass spectrometry
    Chen, Yueqin
    Ma, Ming
    Xu, Hongdan
    Pan, Chunyan
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2024, 42 (09) : 866 - 874
  • [42] Determination of type A trichothecenes in coix seed by magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes coupled with ultra-high performance liquid chromatography-tandem mass spectrometry
    Maofeng Dong
    Wenshuai Si
    Weimin Wang
    Bing Bai
    Dongxia Nie
    Weiguo Song
    Zhihui Zhao
    Yirong Guo
    Zheng Han
    [J]. Analytical and Bioanalytical Chemistry, 2016, 408 : 6823 - 6831
  • [43] Simultaneous determination of seven bisphenol analogues in surface water by solid-phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry
    Wang, Qiuxu
    Feng, Qiyan
    Hu, Guanjiu
    Gao, Zhanqi
    Zhu, Xueqiang
    Epri, James Epua
    [J]. MICROCHEMICAL JOURNAL, 2022, 175
  • [44] Determination of fluoroquinolones in food samples by magnetic solid-phase extraction based on a magnetic molecular sieve nanocomposite prior to high-performance liquid chromatography and tandem mass spectrometry
    Yu, Hao
    Jia, Yuqian
    Wu, Ri
    Chen, Xiangfeng
    Chan, T-W Dominic
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (13) : 2817 - 2826
  • [45] Determination of type A trichothecenes in coix seed by magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes coupled with ultra-high performance liquid chromatography-tandem mass spectrometry
    Dong, Maofeng
    Si, Wenshuai
    Wang, Weimin
    Bai, Bing
    Nie, Dongxia
    Song, Weiguo
    Zhao, Zhihui
    Guo, Yirong
    Han, Zheng
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (24) : 6823 - 6831
  • [46] Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography
    Liu, Xiaomei
    Sun, Zhiwei
    Chen, Guang
    Zhang, Wanwan
    Cai, Yiping
    Kong, Rongmei
    Wang, Xiaoyan
    Suo, Yourui
    You, Jinmao
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1409 : 46 - 52
  • [47] Determination of patulin in apple juice using magnetic solid-phase extraction coupled with high-performance liquid chromatography
    Yu, Youwei
    Fan, Zhefeng
    [J]. FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2017, 34 (02): : 273 - 281
  • [48] Determination of diazinon in water and food samples using magnetic solid-phase extraction coupled with liquid chromatography
    Mohammadnia, Maryam
    Heydari, Rouhollah
    Sohrabi, Mahmoud Reza
    Motiee, Fereshteh
    [J]. SEPARATION SCIENCE PLUS, 2020, 3 (09) : 428 - 437
  • [49] Highly sensitive determination of endocrine disrupting chemicals in foodstuffs through magnetic solid-phase extraction followed by high-performance liquid chromatography-tandem mass spectrometry
    Liu, Jianghua
    Wu, Di
    Yu, Yanxin
    Liu, Jichao
    Li, Guoliang
    Wu, Yongning
    [J]. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2021, 101 (04) : 1666 - 1675
  • [50] Curcumin loaded magnetic graphene oxide solid-phase extraction for the determination of parabens in toothpaste and mouthwash coupled with high performance liquid chromatography
    Razavi, Nourolhoda
    Es'haghi, Zarrin
    [J]. MICROCHEMICAL JOURNAL, 2019, 148 : 616 - 625