Determination of environmental estrogens and bisphenol A in water samples by ultra-high performance liquid chromatography coupled to Q-Exactive high resolution mass spectrometry after magnetic solid-phase extraction

被引:27
|
作者
Zhao, Yan [1 ,3 ,4 ]
Bai, Xiao-Lin [1 ]
Song, Tao [4 ]
Zhang, Guo-Lin [1 ]
Yuan, Yun-Cong [1 ,3 ]
Liu, Yi-Ming [1 ,2 ]
Liao, Xun [1 ]
机构
[1] Chinese Acad Sci, Chengdu Inst Biol, Chengdu 610041, Sichuan, Peoples R China
[2] Jackson State Univ, Dept Chem & Biochem, Jackson, MS 39217 USA
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Sichuan Willtest Technol Co Ltd, Chengdu 610041, Sichuan, Peoples R China
关键词
Water; Environmental estrogens; Bisphenol A; Fe3O4@nSiO(2)@mSiO(2)-CHO-MNPs; Magnetic solid phase extraction; UHPLC-Q-Exactive HRMS; ENDOCRINE-DISRUPTING CHEMICALS; SORPTIVE EXTRACTION; TRACE ANALYSIS; SURFACE-WATER; MICROSPHERES; NANOPARTICLES; REMOVAL; SHELL; CORE; GLUCOCORTICOIDS;
D O I
10.1016/j.microc.2019.104212
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel, simple and rapid method based on the magnetic solid-phase extraction (MSPE) combined with ultra-high performance liquid chromatography coupled to Q-Exactive high resolution mass spectrometry (UHPLC-Q-Exactive HRMS) was developed for the determination of bisphenol A, 17 beta-estradiol, dienestrol, hexestrol, and diethylstilbestrol in water samples. In this study, novel aldehyde group functionalized core-shell mesoporous silica magnetic nanoparticles were used as adsorbents for purification and enrichment of the environmental estrogens and bisphenol A for the first time. The main factors including desorption solvent, adsorbent amount, adsorption time and desorption time affecting the performance of MSPE procedure were investigated in detail. Linearities with determination coefficients higher than 0.998 were obtained for all the target compounds, and the mean recoveries were in the range of 81.7-96.3%. The intra-day and inter-day precision were satisfactory with the relative standard deviations in the range of 2.3-8.1% and 3.5-9.9%, respectively. The limits of detection were found between 0.2 and 3.0 ng/L. Finally, the developed MSPE-UHPLC-Q-Exactive HRMS method was successfully applied for determination of the environmental estrogens and bisphenol A in water samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Determination of fipronil and its metabolites in egg samples by UHPLC coupled with Q-Exactive high resolution mass spectrometry after magnetic solid-phase extraction
    Zhao, Yan
    Bai, Xiao-Lin
    Liu, Yi-Ming
    Liao, Xun
    MICROCHEMICAL JOURNAL, 2021, 169
  • [2] Cucurbit(n)uril-functionalized magnetic composite for the dispersive solid-phase extraction of perfluoroalkyl and polyfluoroalkyl substances in environmental samples with determination by ultra-high performance liquid chromatography coupled to Orbitrap high-resolution mass spectrometry
    Huang, Zhenzhen
    Liu, Peng
    Lin, Xia
    Xing, Yudong
    Zhou, Yan
    Luo, Yuehua
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1674
  • [3] Determination of estrogens by solid-phase quadruplex stable isotope dansylation coupled with liquid chromatography-high resolution mass spectrometry in environmental samples
    Wu, Minghuo
    Miao, Enming
    Xu, Wenxue
    Xu, Weiping
    Hu, Yufeng
    Zhan, Jingjing
    Zhou, Hao
    TALANTA, 2020, 219
  • [4] Determination of bisphenol A in tea samples by solid phase extraction and liquid chromatography coupled to mass spectrometry
    Alnaimat, Ala S.
    Carmen Barciela-Alonso, Maria
    Bermejo-Barrera, Pilar
    MICROCHEMICAL JOURNAL, 2019, 147 : 598 - 604
  • [5] Determination of Estrogens in Milk Samples by Magnetic-Solid-Phase Extraction Technique Coupled With High-Performance Liquid Chromatography
    Wang, Juan
    Cheng, Chunsheng
    Yang, Yaling
    JOURNAL OF FOOD SCIENCE, 2015, 80 (12) : C2655 - C2661
  • [6] Quantitative performance of liquid chromatography coupled to Q-Exactive high resolution mass spectrometry (HRMS) for the analysis of tetracyclines in a complex matrix
    Solliec, Morgan
    Roy-Lachapelle, Audrey
    Sauve, Sebastien
    ANALYTICA CHIMICA ACTA, 2015, 853 : 415 - 424
  • [7] Development of a solid-phase extraction with capillary liquid chromatography tandem mass spectrometry for analysis of estrogens in environmental water samples
    Kozlik, Petr
    Bosakova, Zuzana
    Tesarova, Eva
    Coufal, Pavel
    Cabala, Radomir
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (15) : 2127 - 2132
  • [8] Selective magnetic solid-phase extraction of amide herbicides from fish samples coupled with ultra-high-performance liquid chromatography with tandem mass spectrometry
    Gao, Lei
    Qin, Dongli
    Chen, Zhongxiang
    Bai, Shuyan
    Du, Ningning
    Li, Chenhui
    Hao, Qirui
    Wang, Peng
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (04) : 896 - 907
  • [9] Ultra-high performance liquid chromatography tandem mass spectrometry for the determination of five glycopeptide antibiotics in food and biological samples using solid-phase extraction
    Deng, Fenfang
    Yu, Hong
    Pan, Xinhong
    Hu, Guoyuan
    Wang, Qiqin
    Peng, Rongfei
    Tan, Lei
    Yang, Zhicong
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1538 : 54 - 59
  • [10] Determination of ten iodinated X-ray contrast media by solid-phase extraction and ultra-high performance liquid chromatography coupled with high-resolution orbitrap mass spectrometry
    Cheng, Xinying
    Ji, Qiuyi
    Wang, Xuebing
    Guo, Jiehong
    Chen, Xianxian
    He, Huan
    Yu, Nanyang
    Li, Shiyin
    Yang, Shaogui
    Zhang, Limin
    MICROCHEMICAL JOURNAL, 2022, 177