A Comparison in Proximal Tibial Strain Between Metal-Backed and All-Polyethylene Anatomic Graduated Component Total Knee Arthroplasty Tibial Components

被引:19
|
作者
Small, Scott R. [1 ,2 ]
Berend, Michael E. [1 ]
Ritter, Merrill A. [1 ]
Buckley, Christine A. [2 ]
机构
[1] St Francis Hosp Mooresville, Ctr Hip & Knee Surg, Joint Replacement Surg Indiana Res Fdn, Mooresville, IN USA
[2] Rose Hulman Inst Technol, Terre Haute, IN 47803 USA
来源
JOURNAL OF ARTHROPLASTY | 2010年 / 25卷 / 05期
关键词
loading; total knee arthroplasty; implants; strain; alignment; FINITE-ELEMENT-ANALYSIS; CEMENTED COMPONENTS; IMPLANT MIGRATION; CANCELLOUS BONE; FATIGUE FAILURE; RANDOMIZED RSA; EARLY FIXATION; REPLACEMENT; ALIGNMENT; DESIGNS;
D O I
10.1016/j.arth.2009.06.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Loading in total knee arthroplasty (TKA) is multifactorial and dependent on alignment, ligament balance, patient, and implant factors. Abnormal loading has been linked to clinical failure; however, the respective contribution of each factor to failure is not well known. This study defined the effect of metal backing on loading patterns in the proximal tibia. Composite tibiae were implanted with metal-backed and all-polyethylene Anatomic Graduated Component TKA tibial components (Biomet, Inc, Warsaw, Ind) and coated with photoelastic material allowing full-field dynamic strain quantification. In simulated varus loading distributions, significant increases in measured strain were observed ranging from 40% to 587% for all-polyethylene vs metal-backed tibial components. Higher observed strains in the proximal tibia observed with all-polyethylene tibial components could possibly explain increased clinical failure rates observed with this TKA design.
引用
收藏
页码:820 / 825
页数:6
相关论文
共 50 条
  • [1] A comparison of all-polyethylene and metal-backed tibial components in total knee arthroplasty
    Dojcinovic, S.
    Selmi, T. Ait Si
    Servien, E.
    Verdonk, P. C. M.
    Neyret, P.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (04): : 364 - 372
  • [2] CLINICAL COMPARISON OF ALL-POLYETHYLENE AND METAL-BACKED TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY
    APEL, DM
    TOZZI, JM
    DORR, LD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (273) : 243 - 252
  • [3] All-polyethylene versus metal-backed tibial component in total knee arthroplasty
    Longo, Umile Giuseppe
    Ciuffreda, Mauro
    D'Andrea, Valerio
    Mannering, Nicholas
    Locher, Joel
    Denaro, Vincenzo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (11) : 3620 - 3636
  • [4] All-Polyethylene versus Metal-Backed Tibial Components in Total Knee Arthroplasty
    AbuMoussa, Samuel
    White, Charles Cody
    Eichinger, Josef K.
    Friedman, Richard J.
    JOURNAL OF KNEE SURGERY, 2019, 32 (08) : 714 - 718
  • [5] All-polyethylene versus metal-backed tibial component in total knee arthroplasty
    Umile Giuseppe Longo
    Mauro Ciuffreda
    Valerio D’Andrea
    Nicholas Mannering
    Joel Locher
    Vincenzo Denaro
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 3620 - 3636
  • [6] All-polyethylene compared with metal-backed tibial components in total knee arthroplasty
    Hart, WJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (08): : 1615 - 1615
  • [7] Metal-backed and all-polyethylene tibial components in total knee replacement
    Rodriguez, JA
    Baez, N
    Rasquinha, V
    Ranawat, CS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 174 - 183
  • [8] Cemented All-Polyethylene and Metal-Backed Polyethylene Tibial Components Used for Primary Total Knee Arthroplasty
    Voigt, Jeffrey
    Mosier, Michael
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (19): : 1790 - 1798
  • [9] Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty
    van Hamersveld, Koen T.
    Marang-Van de Mheen, Perla J.
    Nelissen, Rob G. H. H.
    Toksvig-Larsen, Soren
    ACTA ORTHOPAEDICA, 2018, 89 (04) : 412 - 417
  • [10] All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty
    Jean Brihault
    Alessandro Navacchia
    Silvia Pianigiani
    Luc Labey
    Ronny De Corte
    Valerio Pascale
    Bernardo Innocenti
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 2550 - 2559