Annual simulation, energy and economic analysis of hybrid heat pump systems for residential buildings

被引:50
作者
Bagarella, G. [1 ]
Lazzarin, R. [1 ]
Noro, M. [1 ]
机构
[1] Univ Padua, Dept Management & Engn, Vicenza, Italy
关键词
Hybrid system; Heat pump; Boiler; Cut off temperature; Bivalent temperature; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2016.01.089
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air source heat pumps have a well known unfavourable characteristic: in the coldest period of the year, when the building heating load is at maximum, the heat pump capacity is reduced. A possible solution is to size the heat pump to cover only a fraction of the peak load using a second heat generator in "hybrid heat pump system". In this study, a dynamic model of a hybrid system was built, and several seasonal simulations were carried out (considering two different climates) to study how the choice of the cut off temperature can influence the annual efficiency of the system and to understand if a bivalent parallel plant can lead to energy savings compared to a bivalent alternative system. With both the considered climates, when a large size heat pump is selected (low bivalent temperature), there might be no benefits by setting a cut off temperature lower than the bivalent temperature, and the differences between the energy performances of the bivalent alternative system and those of the bivalent parallel system are negligible. On the other hand, when a low size heat pump is preferred (high bivalent temperature), the bivalent parallel system can lead to appreciable energy savings compared to a bivalent alternative plant. The main economic advantages of a hybrid system, with respect to the monovalent heat-pump plant, comes from the lower annual electric and gas energy needs. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:485 / 494
页数:10
相关论文
共 18 条
[1]  
AiCARR Italian Association for Air Conditioning Heating and Refrigeration, 2015, ACQ CALD SAN DIM ACC
[2]  
[Anonymous], 2015, EMERSON COPELAND SEL
[3]  
[Anonymous], 2015, COMP PERC PREZZ EN E
[4]   Domestic demand-side management (DSM): Role of heat pumps and thermal energy storage (TES) systems [J].
Arteconi, A. ;
Hewitt, N. J. ;
Polonara, F. .
APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) :155-165
[5]   Cycling losses in refrigeration equipment: An experimental evaluation [J].
Bagarella, Giacomo ;
Lazzarin, Renato M. ;
Lamanna, Biagio .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (08) :2111-2118
[6]   Energy and economic analysis of different heat pump systems for space heating [J].
Busato, Filippo ;
Lazzarin, Renato M. ;
Noro, Marco .
INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2012, 7 (02) :104-112
[7]   A simplified method to evaluate the seasonal energy performance of water chillers [J].
Cecchinato, Luca ;
Chiarello, Manuel ;
Corradi, Marco .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (09) :1776-1786
[8]   Experimental assessment and dynamic analysis of a hybrid generator composed of an air source heat pump coupled with a condensing gas boiler in a residential building [J].
Di Perna, Costanzo ;
Magri, Guglielmo ;
Giuliani, Giuliano ;
Serenelli, Giorgio .
APPLIED THERMAL ENGINEERING, 2015, 76 :86-97
[9]   Performance of a finned-tube evaporator optimized for different refrigerants and its effect on system efficiency [J].
Domanski, PA ;
Yashar, D ;
Kim, MS .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (06) :820-827
[10]   An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump [J].
Dong, Jiankai ;
Deng, Shiming ;
Jiang, Yiqiang ;
Xia, Liang ;
Yao, Yang .
APPLIED THERMAL ENGINEERING, 2012, 37 :380-387