Diffusion tensor magnetic resonance imaging and fiber tracking in spinal cord lesions:: Current and future indications

被引:64
作者
Ducreux, Denis
Fillard, Pierre
Facon, David
Ozanne, Augustin
Lepeintre, Jean-Franois
Renoux, Jerome
Tadie, Marc
Lasjaunias, Pierre
机构
[1] Univ Paris 11, Dept Neuroradiol, CHU Bicetre, F-94270 Le Kremlin Bicetre, France
[2] INSERM, LIMEC, UMR 788, F-94275 Le Kremlin Bicetre, France
[3] Asclepios Res Project, F-06902 Sophia Antipolis, France
[4] Univ Paris 11, Dept Neurosurg, CHU Bicetre, F-94270 Le Kremlin Bicetre, France
关键词
D O I
10.1016/j.nic.2006.11.005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Diffusion-weighted imaging and fractional anisotropy may be more sensitive than other conventional magnetic resonance imaging techniques to detect, characterize, and map the extent of spinal cord lesions. Fiber tracking offers the possibility of visualizing the integrity of white matter tracts surrounding some lesions, and this information may help in formulating a differential diagnosis and in planning biopsies or resection. Fractional anisotropy measurements may also play a role in predicting the outcome of patients who have spinal cord lesions. In this article, we address several conditions in which diffusion-weighted imaging and fiber tracking is known to be useful and speculate on others in which we believe these techniques will be useful in the near future.
引用
收藏
页码:137 / +
页数:12
相关论文
共 35 条
  • [1] Alexander AL, 2000, MAGNET RESON MED, V44, P283, DOI 10.1002/1522-2594(200008)44:2<283::AID-MRM16>3.0.CO
  • [2] 2-V
  • [3] [Anonymous], 1998, J COMPUT ASSIST TOMO
  • [4] Bammer R, 2000, AM J NEURORADIOL, V21, P587
  • [5] A simplified method to measure the diffusion tensor from seven MR images
    Basser, PJ
    Pierpaoli, C
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) : 928 - 934
  • [6] MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. BIOPHYSICAL JOURNAL, 1994, 66 (01) : 259 - 267
  • [7] Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
  • [8] ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03): : 247 - 254
  • [9] BASSER PJ, 1998, P INT SOC MAGN RES M, P1226
  • [10] Diffusion tensor imaging in multiple sclerosis:: a tool for monitoring changes in normal-appearing white matter
    Cassol, E
    Ranjeva, JP
    Ibarrola, D
    Mékies, C
    Manelfe, C
    Clanet, M
    Berry, I
    [J]. MULTIPLE SCLEROSIS JOURNAL, 2004, 10 (02) : 188 - 196