Simultaneous MV-kV imaging for intrafractional motion management during volumetric-modulated arc therapy delivery

被引:25
作者
Hunt, Margie A. [1 ]
Sonnick, Mark [2 ]
Pham, Hai [1 ]
Regmi, Rajesh [1 ]
Xiong, Jian-ping [1 ]
Morf, Daniel [3 ]
Mageras, Gig S. [1 ]
Zelefsky, Michael [4 ]
Zhang, Pengpeng [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, Box 84,1275 York Ave, New York, NY 10065 USA
[2] Weill Cornell Med Coll, New York, NY USA
[3] Varian Med Syst, Palo Alto, CA USA
[4] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, 1275 York Ave, New York, NY 10021 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2016年 / 17卷 / 02期
关键词
image-guided radiotherapy; motion monitoring; fiducial tracking; INTERNAL MARKER TRACKING; REAL-TIME TRACKING; DIGITAL TOMOSYNTHESIS; GUIDED RADIOTHERAPY; PROSTATE-GLAND; SYSTEM; LOCALIZATION; MEGAVOLTAGE; VERIFICATION; ALGORITHM;
D O I
10.1120/jacmp.v17i2.5836
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the accuracy and clinical feasibility of a motion monitoring method employing simultaneously acquired MV and kV images during volumetric-modulated arc therapy (VMAT). Short-arc digital tomosynthesis (SA-DTS) is used to improve the quality of the MV images that are then combined with orthogonally acquired kV images to assess 3D motion. An anthropomorphic phantom with implanted gold seeds was used to assess accuracy of the method under static, typical prostatic, and respiratory motion scenarios. Automatic registration of kV images and single MV frames or MV SA-DTS reconstructed with arc lengths from 2 degrees to 7 degrees with the appropriate reference fiducial template images was performed using special purpose-built software. Clinical feasibility was evaluated by retrospectively analyzing images acquired over four or five sessions for each of three patients undergoing hypofractionated prostate radiotherapy. The standard deviation of the registration error in phantom using MV SA-DTS was similar to single MV images for the static and prostate motion scenarios (sigma = 0.25 mm). Under respiratory motion conditions, the standard deviation of the registration error increased to 0.7 mm and 1.7 mm for single MV and MV SA-DTS, respectively. Registration failures were observed with the respiratory scenario only and were due to motion-induced fiducial blurring. For the three patients studied, the mean and standard deviation of the difference between automatic registration using 4 degrees MV SA-DTS and manual registration using single MV images results was 0.07 +/- 0.52 mm. The MV SA-DTS results in patients were, on average, superior to single-frame MV by nearly 1 mm - significantly more than what was observed in phantom. The best MV SA-DTS results were observed with arc lengths of 3 degrees to 4 degrees. Registration failures in patients using MV SA-DTS were primarily due to blockage of the gold seeds by the MLC. The failure rate varied from 2% to 16%. Combined MV SA-DTS and kV imaging is feasible for intratreatment motion monitoring during VMAT of anatomic sites where limited motion is expected, and improves registration accuracy compared to single MV/kV frames. To create a clinically robust technique, further improvements to ensure visualization of fiducials at the desired control points without degradation of the treatment plan are needed.
引用
收藏
页码:473 / 486
页数:14
相关论文
共 29 条
  • [1] Prostate planning treatment volume margin calculation based on the exactrac X-ray 6D image-guided system:: Margins for various clinical implementations
    Alonso-Arrizabalaga, Sara
    Gonzalez, Luis Brualla
    Ferrando, Juan V. Rosello
    Peidro, Jorge Pastor
    Torrecilla, Jose Lopez
    Meseguer, Domingo Planes
    Hernandez, Trinidad Garcia
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : 936 - 943
  • [2] Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy
    Azcona, Juan Diego
    Li, Ruijiang
    Mok, Edward
    Hancock, Steven
    Xing, Lei
    [J]. MEDICAL PHYSICS, 2013, 40 (03)
  • [3] FIRST DEMONSTRATION OF COMBINED KV/MV IMAGE-GUIDED REAL-TIME DYNAMIC MULTILEAF-COLLIMATOR TARGET TRACKING
    Cho, Byungchul
    Poulsen, Per R.
    Sloutsky, Alex
    Sawant, Amit
    Keall, Paul J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (03): : 859 - 867
  • [4] The first clinical treatment with kilovoltage intrafraction monitoring (KIM): A real-time image guidance method
    Keall, Paul J.
    Ng, Jin Aun
    O'Brien, Ricky
    Colvill, Emma
    Huang, Chen-Yu
    Poulsen, Per Rugaard
    Fledelius, Walther
    Juneja, Prabhjot
    Simpson, Emma
    Bell, Linda
    Alfieri, Florencia
    Eade, Thomas
    Kneebone, Andrew
    Booth, Jeremy T.
    [J]. MEDICAL PHYSICS, 2015, 42 (01) : 354 - 358
  • [5] A METHOD FOR SELECTIVE REMOVAL OF OUT-OF-PLANE STRUCTURES IN DIGITAL TOMOSYNTHESIS
    KOLITSI, Z
    PANAYIOTAKIS, G
    PALLIKARAKIS, N
    [J]. MEDICAL PHYSICS, 1993, 20 (01) : 47 - 50
  • [6] Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy
    Kupelian, Patrick
    Willoughby, Twyla
    Mahadevan, Arul
    Djemil, Toufik
    Weinstein, Geoffrey
    Jani, Shirish
    Enke, Charles
    Solberg, Timothy
    Flores, Nicholas
    Liu, David
    Beyer, David
    Levine, Lisa
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04): : 1088 - 1098
  • [7] Observations on real-time prostate gland motion using electromagnetic tracking
    Langen, Katja M.
    Willoughby, Twyla R.
    Meeks, Sanford L.
    Santhanam, Anand
    Cunningham, Alexis
    Levine, Lisa
    Kupelian, Patrick A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04): : 1084 - 1090
  • [8] Intrafraction Verification of Gated RapidArc by Using Beam-Level Kilovoltage X-Ray Images
    Li, Ruijiang
    Mok, Edward
    Chang, Daniel T.
    Daly, Megan
    Loo, Billy W., Jr.
    Diehn, Maximilian
    Quynh-Thu Le
    Koong, Albert
    Xing, Lei
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (05): : E709 - E715
  • [9] Real-time automatic fiducial marker tracking in low contrast cine-MV images
    Lin, Wei-Yang
    Lin, Shu-Fang
    Yang, Sheng-Chang
    Liou, Shu-Cheng
    Nath, Ravinder
    Liu, Wu
    [J]. MEDICAL PHYSICS, 2013, 40 (01)
  • [10] Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging
    Liu, W.
    Wiersma, R. D.
    Mao, W.
    Luxton, G.
    Xing, L.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24) : 7197 - 7213