Charge-monitoring laser-induced acoustic desorption mass spectrometry for cell and microparticle mass distribution measurement

被引:58
作者
Peng, Wen-Ping
Lin, Huan-Chang
Lin, Hsin-Hung
Chu, Minglee
Yu, Alice L.
Chang, Huan-Cheng
Chen, Chung-Hsuan [1 ]
机构
[1] Acad Sinica, Genom Res Ctr, Taipei 115, Taiwan
[2] Acad Sinica, Inst Phys, Taipei 115, Taiwan
[3] Acad Sinica, Inst Atom & Mol Sci, Taipei 115, Taiwan
关键词
cells; charge detection; ion trap; mass spectrometry; microparticles;
D O I
10.1002/anie.200700309
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Mass exodus: A mass spectrometer for the rapid measurement of mass distributions of cells and microparticles is described. A discharge process is used to provide cells with thousands of charges so that direct charge measurement can be achieved. This device was used to measure microparticles with masses as high as 1015 Da and to distinguish cancer cells from normal cells. (Figure Presented). © 2007 Wiley-VCH Verlag GmbH & Co. KGaA.
引用
收藏
页码:3865 / 3869
页数:5
相关论文
共 31 条
[1]   Electrospray ionization of a whole virus: Analyzing mass, structure, and viability [J].
Bothner, B ;
Siuzdak, G .
CHEMBIOCHEM, 2004, 5 (03) :258-260
[2]   Ion trap mass spectrometry of fluorescently labeled nanoparticles [J].
Cai, Y ;
Peng, WP ;
Chang, HC .
ANALYTICAL CHEMISTRY, 2003, 75 (08) :1805-1811
[3]   Analysis of polyethylene by using cyclopentadienyl cobalt chemical ionization combined with laser-induced acoustic desorption/Fourier transform ion cyclotron resonance mass spectrometry [J].
Campbell, JL ;
Fiddler, MN ;
Crawford, KE ;
Gqamana, PP ;
Kenttämaa, HI .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4020-4026
[4]   TRAPPING, DETECTION, AND MASS DETERMINATION OF COLIPHAGE T4 DNA IONS OF 10(8) DA BY ELECTROSPRAY-IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, RD ;
CHENG, XH ;
MITCHELL, DW ;
HOFSTADLER, SA ;
WU, QY ;
ROCKWOOD, AL ;
SHERMAN, MG ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1995, 67 (07) :1159-1163
[5]  
FOLEY GE, 1965, CANCER, V18, P522, DOI 10.1002/1097-0142(196504)18:4<522::AID-CNCR2820180418>3.0.CO
[6]  
2-J
[7]  
Fuerstenau S.D., 2001, Angew. Chem. Int. Ed, V113, P559
[8]   Molecular weight determination of megadalton DNA electrospray ions using charge detection time-of-flight mass spectrometry [J].
Fuerstenau, SD ;
Benner, WH .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (15) :1528-1538
[9]  
Fuerstenau SD, 2001, ANGEW CHEM INT EDIT, V40, P982, DOI 10.1002/1521-3773(20010316)40:6<982::AID-ANIE9822>3.0.CO
[10]  
2-4