Static analysis of a new scheme of two stage refrigeration cycle with the combination of FAM Z01 and FAM Z05 adsorbents

被引:14
作者
Akisawa, Atsushi [1 ]
Umair, Muhammad [2 ]
Enoki, Koji [3 ]
Nakayama, Masayuki [1 ]
机构
[1] Tokyo Univ Agr & Technol, 2-24-16 Nakacho, Koganei, Tokyo 1848588, Japan
[2] PMAS Arid Agr Univ Rawalpindi, Muree Rd, Shamsabad 46000, Rawalpindi, Pakistan
[3] Univ Electrocommun, 1-5-1 Chofugaoka, Chofu, Tokyo 1828585, Japan
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2018年 / 92卷
基金
日本科学技术振兴机构;
关键词
Adsorption refrigeration; Two stage adsorption cycle; FAM Z01/Z05; Duhring diagram; WATER ADSORPTION CHILLER; PERFORMANCE EVALUATION; SILICA-GEL; DRIVEN; SYSTEM; ZEOLITES; PAIR;
D O I
10.1016/j.ijrefrig.2018.04.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents static analyses of two stage adsorption cycle using FAM Z01 and FAM Z05 as the adsorbents. The conventional two stage system consists of four adsorbent beds. In contrast, in new scheme three beds were used assigning FAM Z01 and FAM Z05 combination for low and high pressure sides, respectively. The objectives of this study were to evaluate the performance of two stage cycle with the Z01 and Z05 combination of adsorbent pair, and to compare the performance with that of the conventional two stage cycle using Silica-gel. Static analysis based on Duhring diagram was employed to estimate the performances of specific cooing effect (SCE) and COP. It was found that the cycle with new combination gives SCE more than twice compared with the conventional Silica-gel-water system at the heat source temperature of 55 degrees C. The sensitivity analysis was also performed for optimal mass allocation to adsorbent beds. (C) 2018 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:143 / 153
页数:11
相关论文
共 30 条
[11]   Development of novel type of two-stage adsorption chiller with different adsorbents [J].
He, Z. H. ;
Huang, H. Y. ;
Deng, L. S. ;
Yuan, H. R. ;
Kobayashi, N. ;
Kubota, M. ;
Huhetaoli ;
Zhao, D. D. .
INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 :1996-1999
[12]   Novel water vapor adsorbent FAM-Z01 and its applicability to an adsorption heat pump [J].
Kakiuchi, H ;
Shimooka, S ;
Iwade, M ;
Oshima, K ;
Yamazaki, M ;
Terada, S ;
Watanabe, H ;
Takewaki, T .
KAGAKU KOGAKU RONBUNSHU, 2005, 31 (05) :361-364
[13]   Adsorption characteristics of AQSOA zeolites and water for adsorption chillers [J].
Kayal, Sibnath ;
Sun Baichuan ;
Saha, Bidyut Baran .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 92 :1120-1127
[14]   Optimal solar COP prediction of a solar-assisted adsorption refrigeration system working with activated carbon/methanol as working pairs using direct and inverse artificial neural network [J].
Laidi, Maamar ;
Hanini, Salah .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (01) :247-257
[15]   Performance evaluation of a zeolite-water adsorption chiller with entropy analysis of thermodynamic insight [J].
Li, Ang ;
Bin Ismail, Azhar ;
Thu, Kyaw ;
Ng, Kim Choon ;
Loh, Wai Soong .
APPLIED ENERGY, 2014, 130 :702-711
[16]  
Marlinda, 2014, Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers, V31, P1
[17]   Simulation study of a two-stage adsorber system [J].
Mitra, Sourav ;
Kumar, Pramod ;
Srinivasan, Kandadai ;
Dutta, Pradip .
APPLIED THERMAL ENGINEERING, 2014, 72 (02) :283-288
[18]   Experimental investigation on the optimal performance of Zeolite-water adsorption chiller [J].
Myat, Aung ;
Choon, Ng Kim ;
Thu, Kyaw ;
Kim, Young-Deuk .
APPLIED ENERGY, 2013, 102 :582-590
[19]   Performance Comparison of Three-Bed Adsorption Cooling System With Optimal Cycle Time Setting [J].
Rahman, Abul Fazal Mohammad Mizanur ;
Miyazaki, Takahiko ;
Ueda, Yuki ;
Saha, Bidyut Baran ;
Akisawa, Atsushi .
HEAT TRANSFER ENGINEERING, 2013, 34 (11-12) :938-947
[20]  
Rahman AF, 2012, J ENVIRON ENG, V7, P92