Effect of Induced Periimplantitis on Dental Implants With and Without Ultrathin Hydroxyapatite Coating

被引:10
作者
Madi, Marwa [1 ]
Zakaria, Osama [2 ]
Ichinose, Shizuko [3 ]
Kasugai, Shohei [4 ]
机构
[1] Univ Alexandria, Dept Oral Med Periodontol Diag & Radiol, Fac Dent, Alexandria 21411, Egypt
[2] Pharos Univ, Fac Dent, Dept Oral Surg, Alexandria, Egypt
[3] Tokyo Med & Dent Univ, Res Ctr Med & Dent Sci, Tokyo, Japan
[4] Tokyo Med & Dent Univ, Oral Implantol & Regenerat Dent Med, Tokyo, Japan
关键词
dental implants; hydroxyapatite; periimplantitis; bone; CALCIUM-PHOSPHATE COATINGS; VIVO DISSOLUTION BEHAVIOR; INDUCED PERI-IMPLANTITIS; TITANIUM IMPLANTS; CLINICAL-PERFORMANCE; BONE RESPONSE; PART II; SURFACE; OSSEOINTEGRATION;
D O I
10.1097/ID.0000000000000331
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to compare the effect of ligature-induced periimplantitis on dental implants with and without hydroxyapatite (HA) coat. Methods: Thirty-two dental implants (3.3 mm wide, 13 mm long) with 4 surface treatments (8 implant/group) (M: machined, SA: sandblasted acid etched, S: sputter HA coat and P: plasma-sprayed HA coat) were inserted into canine mandibles. After 12 weeks, oral hygiene procedures were stopped and silk ligatures were placed around the implant abutments to allow plaque accumulation for the following 16 weeks. Implants with the surrounding tissues were retrieved and prepared for histological examination. Bone-to-implant contact (BIC) and implant surfaces were examined using scan-ning electron microscopy and energy dispersive x-ray spectroscopy. Results: Histological observation revealed marginal bone loss and large inflammatory cell infiltrates in the periimplant soft tissue. Sputter HA implants showed the largest BIC (98.1%) and machined implant showed the smallest values (70.4%). After 28 weeks, thin sputter HA coat was almost completely dissolved, whereas plasma-sprayed HA coat showed complete thickness preservation. Conclusion: Thin sputter HA-coated implants showed more bone implant contact and less marginal bone loss than thick HA-coated implants under periimplantitis condition.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 45 条
[1]   Long-term effects of magnetron-sputtered calcium phosphate coating on osseointegration of dental implants in non-human primates [J].
Alexander, Fuegl ;
Christian, Ulm ;
Stefan, Tangl ;
Christoph, Vasak ;
Reinhard, Gruber ;
Georg, Watzek .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (02) :183-188
[2]   Bone properties surrounding hydroxyapatite-coated custom osseous integrated dental implants [J].
Baker, M. I. ;
Eberhardt, A. W. ;
Martin, D. M. ;
McGwin, G. ;
Lemons, J. E. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 95B (01) :218-224
[3]  
Brunski JB, 2000, INT J ORAL MAX IMPL, V15, P15
[4]   Highly crystalline Mp-1™ hydroxylapatite coating Part II:: In vivo performance on endosseous root implants in dogs [J].
Burgess, AV ;
Story, BJ ;
Wagner, WR ;
Trisi, P ;
Pikos, MA ;
Guttenberg, SA .
CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (04) :257-266
[5]   Enhanced bone apposition to a chemically modified SLA titanium surface [J].
Buser, D ;
Broggini, N ;
Wieland, M ;
Schenk, RK ;
Denzer, AJ ;
Cochran, DL ;
Hoffmann, B ;
Lussi, A ;
Steinemann, SG .
JOURNAL OF DENTAL RESEARCH, 2004, 83 (07) :529-533
[6]  
Cochran DL, 1998, J BIOMED MATER RES, V40, P1, DOI 10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO
[7]  
2-Q
[8]   THE ADVANTAGES OF COATED TITANIUM IMPLANTS PREPARED BY RADIOFREQUENCY SPUTTERING FROM HYDROXYAPATITE [J].
COOLEY, DR ;
VANDELLEN, AF ;
BURGESS, JO ;
WINDELER, AS .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (01) :93-100
[9]   The effect on bone growth enhancement of implant coatings with hydroxyapatite and collagen deposited electrochemically and by plasma spray [J].
Daugaard, Henrik ;
Elmengaard, Brian ;
Bechtold, Joan E. ;
Jensen, Thomas ;
Soballe, Kjeld .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2010, 92A (03) :913-921
[10]  
Davies John E, 2003, J Dent Educ, V67, P932