POWERLINE INTERFERENCE REMOVAL TECHNIQUE USING DIGITAL NOTCH FILTER IN ECG

被引:0
|
作者
Rahul, Jagdeep [1 ]
Sora, Marpe [1 ]
机构
[1] Rajiv Gandhi Univ, Dept Elect & Commun Engn, Itanagar 791112, Arunachal Prade, India
来源
ADVANCES AND APPLICATIONS IN MATHEMATICAL SCIENCES | 2021年 / 20卷 / 07期
关键词
breast cancer classification; transfer learning; DESIGN;
D O I
暂无
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
ECG signal analysis plays a vital role in the diagnosis of heart abnormities. The presence of noise can change the primitive characteristics of the ECG signal. The ECG signal gets affected by the powerline interference noise (PLI) during the time of signal acquisition. In this paper, digital quality factor (Q) varying notch IIR filter with a zero-phase filtering technique is proposed to remove the power line interference in the ECG signal. The correlation factor is estimated for its validation between the filtered ECG and raw ECG signal. The quality factor of digital IIR notch filter is tuned to achieve a better correlation coefficient and signal to noise ratio (SNR) of filtered ECG signal. The highest correlation factor unity is achieved at the quality factor of 1. The proposed technique is also tested and validated on the MIT-BIH database.
引用
收藏
页码:1269 / 1277
页数:9
相关论文
共 50 条
  • [11] ADAPTIVE DIGITAL NOTCH FILTER DESIGN ON THE UNIT-CIRCLE FOR THE REMOVAL OF POWERLINE NOISE FROM BIOMEDICAL SIGNALS
    FERDJALLAH, M
    BARR, RE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (06) : 529 - 536
  • [12] Artifact Removal from ECG Signal using Notch Filter for Developing Countries
    Gupta, Varun
    Singh, Gavendra
    Sharma, Rohit
    Pahuja, Sharvan Kumar
    MEMS, NANO AND SMART SYSTEMS, PTS 1-6, 2012, 403-408 : 120 - +
  • [13] Design and implementation of IIR Notch filter for removal of power line interference from noisy ECG signal
    Chourasia, Ravi Kumar
    Narwaria, Ravindra Pratap
    INTERNATIONAL JOURNAL OF COMPUTER SCIENCE AND NETWORK SECURITY, 2012, 12 (09): : 70 - 74
  • [14] Fractal and EMD based removal of baseline wander and powerline interference from ECG signals
    Agrawal, Sakshi
    Gupta, Anubha
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (11) : 1889 - 1899
  • [15] A new method based CEEMDAN for removal of baseline wander and powerline interference in ECG signals
    Yao, Liping
    Pan, Zhongliang
    OPTIK, 2020, 223
  • [16] An Adaptive Notch Filter for Narrow Band Interference Removal
    Varshney, Neeraj
    Jain, R. C.
    2013 NATIONAL CONFERENCE ON COMMUNICATIONS (NCC), 2013,
  • [17] Simultaneous powerline interference and baseline wander removal from ECG and EMG signals by sinusoidal modeling
    Zivanovic, Miroslav
    Gonzalez-Izal, Miriam
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (10) : 1431 - 1441
  • [18] Separating Nonstationary Powerline Interference from ECG Using Empirical Mode Decomposition
    Li, Guo-jun
    Hao, Xiao-jie
    Hui-Zhong
    Zhou, Xiao-na
    MECHANICAL ENGINEERING AND GREEN MANUFACTURING II, PTS 1 AND 2, 2012, 155-156 : 736 - +
  • [19] Powerline interference suppression in high-resolution ECG
    Bazhyna, A
    Christov, II
    Gotchev, A
    Daskalov, IK
    Egiazarian, K
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 561 - 564
  • [20] Removal of ECG Artifacts From EEG Using an Effective Recursive Least Square Notch Filter
    Dai, Chenxi
    Wang, Jianjie
    Xie, Jialing
    Li, Weiming
    Gong, Yushun
    Li, Yongqin
    IEEE ACCESS, 2019, 7 : 158872 - 158880