Anodic Oxidized Nanotubular Titanium Implants Enhance Bone Morphogenetic Protein-2 Delivery

被引:56
作者
Bae, In-Ho [2 ,3 ]
Yun, Kwi-Dug [2 ,3 ]
Kim, Hyun-Seung [4 ]
Jeong, Byung-Chul [2 ,3 ]
Lim, Hyun-Pil [2 ,3 ]
Park, Sang-Won [1 ,2 ,3 ]
Lee, Kwang-Min [1 ,5 ]
Lim, Young-Chai [6 ]
Lee, Kyung-Ku [7 ]
Yang, Yunzhi [1 ,8 ]
Koh, Jeong-Tae [1 ,2 ,3 ]
机构
[1] Chonnam Natl Univ, Res Inst Funct Surface Engn, Kwangju, South Korea
[2] Chonnam Natl Univ, Sch Dent, Dent Sci Res Inst, Kwangju, South Korea
[3] Chonnam Natl Univ, Sch Dent, Project BK21, Kwangju, South Korea
[4] Megagen Co Ltd, Kyeongsan, South Korea
[5] Chonnam Natl Univ, Div Engn & Mat Sci, Kwangju, South Korea
[6] Chonnam Natl Univ, Res Inst Med Sci, Kwangju, South Korea
[7] R&D Ctr Titanium & Special Alloys, Kwangju, South Korea
[8] Univ Texas Hlth Sci Ctr Houston, Dept Restorat Dent & Biomat, Houston Biomat Res Ctr, Houston, TX USA
关键词
titanium implant; anodic oxidation; nanotube; bone morphogenetic protein-2 delivery; osseointegration; osteoblast differentiation; FACTOR-BETA SUPERFAMILY; IN-VITRO; BIOMEDICAL APPLICATIONS; OSTEOGENIC PROTEIN; SURFACE; GROWTH; BMP; ATTACHMENT; RESPONSES; MEMBERS;
D O I
10.1002/jbm.b.31606
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Implant failure has been attributed to loosening of an implant from the host bone possibly due to poor osseointegration One promising strategy for improving osseointegration is to develop a functional implant surface that promotes osteoblast differentiation In this study, a titanium (Ti) surface was functionalized by an anodic oxidation process and was loaded with recombinant human bone morphogenetic protein-2 (rhBMP-2) The following four groups of Ti surfaces were prepared. machined (M), anodized machined (MA), resorbable blast medium (RBM), and anodized RBM (RBMA) The surfaces were characterized by scanning electron microscopy and contact angle measurements The results showed that a Ti oxide layer (TiO2) was observed in the anodized surfaces in the form of nanotubes, similar to 100 nm in diameter and 500 nm in length The hydrophilic properties of the anodized surfaces were significantly improved The adsorbed rhBMP-2 loaded on the nonanodized surfaces and lyophilized showed spherical particle morphology However, the adsorbed rhBMP-2 showed a dispersed pattern over the anodized surfaces The velocity of the rhBMP-2 released from the surfaces was measured to determine if the anodized surface can improve in delivery efficiency The results showed that the release velocity of the rhBMP-2 from the anodized surfaces was sustained when compared with that of the nonanodized surfaces In addition, the rhBMP-2 released from the surface was found to be bioactive according to the alkaline phosphatase activity and the level of calcium mineral deposition These results suggest that the TiO2 nano-tubular structure formed by anodizing is a promising configuration for sustained rhBMP-2 delivery (C) 2010 Wiley Periodicals, Inc J Biomed Mater Res Part B Appl Biomater 93B 484-491, 2010
引用
收藏
页码:484 / 491
页数:8
相关论文
共 35 条
[1]   BMP stimulation of bone response adjacent to titanium implants in vivo [J].
Bessho, K ;
Carnes, DL ;
Cavin, R ;
Chen, HY ;
Ong, JL .
CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (03) :212-218
[2]   IDENTIFICATION OF TRANSFORMING GROWTH-FACTOR-BETA FAMILY MEMBERS PRESENT IN BONE-INDUCTIVE PROTEIN PURIFIED FROM BOVINE BONE [J].
CELESTE, AJ ;
IANNAZZI, JA ;
TAYLOR, RC ;
HEWICK, RM ;
ROSEN, V ;
WANG, EA ;
WOZNEY, JM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (24) :9843-9847
[3]   OSTEOINDUCTIVE PROTEINS [J].
ELIMA, K .
ANNALS OF MEDICINE, 1993, 25 (04) :395-402
[4]   In vitro and in vivo behaviour of Ca- and P-enriched anodized titanium [J].
Fini, M ;
Cigada, A ;
Rondelli, G ;
Chiesa, R ;
Giardino, R ;
Giavaresi, G ;
Aldini, NN ;
Torricelli, P ;
Vicentini, B .
BIOMATERIALS, 1999, 20 (17) :1587-1594
[5]   Microfabricated porous silicon particles enhance paracellular delivery of insulin across intestinal Caco-2 cell monolayers [J].
Foraker, AB ;
Walczak, RJ ;
Cohen, MH ;
Boiarski, TA ;
Grove, CF ;
Swaan, PW .
PHARMACEUTICAL RESEARCH, 2003, 20 (01) :110-116
[6]   Anodic plasma-chemical treatment of CP titanium surfaces for biomedical applications [J].
Frauchiger, VM ;
Schlottig, F ;
Gasser, B ;
Textor, M .
BIOMATERIALS, 2004, 25 (04) :593-606
[7]  
GOTTLANDER M, 1991, International Journal of Oral and Maxillofacial Implants, V6, P399
[8]  
KAKOLI D, 2007, ACTA BIOMATER, V3, P573
[9]   Fabrication and Characterization of Functionally Graded Nano-Micro Porous Titanium Surface by Anodizing [J].
Kim, Hyun-Seung ;
Yang, Yunzhi ;
Koh, Jeong-Tae ;
Lee, Kyung-Ku ;
Lee, Doh-Jae ;
Lee, Kwang-Min ;
Park, Sang-Won .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 88B (02) :427-435
[10]  
LIU Y, 2008, BIOMATERIALS BIOMEDI, P115