Avoiding errors in the laboratory evaluation of potent lupus anticoagulants

被引:12
作者
Penmetsa, Gopi K. [3 ]
Rodgers, George M. [1 ,2 ,3 ]
Smock, Kristi J. [1 ,2 ]
机构
[1] ARUP Labs, Salt Lake City, UT 84108 USA
[2] Univ Utah, Hlth Sci Ctr, Dept Pathol, Salt Lake City, UT 84132 USA
[3] Univ Utah, Hlth Sci Ctr, Dept Med, Salt Lake City, UT 84132 USA
关键词
FACTOR-VIII ANTIBODIES; BETHESDA ASSAY; ELISA SYSTEM; ACTIN FS; DIAGNOSIS; UPDATE; CRITERIA; SAMPLES;
D O I
10.1002/ajh.21666
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 56-year-old female was referred to us for evaluation of a prolonged partial thromboplastin time (PTT) without correction in a 1:1 mix (evidence of an inhibitor), markedly low factor IX activity (1% or less on multiple occasions), and factor IX inhibitor (ranging from 19 to 40 Bethesda units on multiple occasions). Her prothrombin time (PT) was normal. No other laboratory results were provided at the time of her referral. Her physician had treated her with cyclophosphamide and prednisone for a presumed acquired factor IX antibody in preparation for orthopedic surgery.
引用
收藏
页码:272 / 274
页数:3
相关论文
共 17 条
[1]   An approach to factor assays in patients with strong lupus anticoagulants [J].
Armitage, J ;
Ashcraft, J ;
Kim, A ;
Kaplan, HS .
CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 1995, 1 (02) :125-130
[2]  
Blanco AN, 2000, HAEMATOLOGICA, V85, P1045
[3]  
Blanco AN, 2002, HAEMATOLOGICA, V87, P271
[4]  
BRANDT JT, 1995, THROMB HAEMOSTASIS, V74, P1185
[5]   Comparison of three methods for measuring factor VIII levels in plasma [J].
Chandler, WL ;
Ferrell, C ;
Lee, J ;
Tun, T ;
Kha, H .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 120 (01) :34-39
[6]  
CRUICKSHANK MK, 1994, ARCH PATHOL LAB MED, V118, P9
[7]  
de Maistre E, 1998, THROMB HAEMOSTASIS, V79, P237
[8]  
Ghirarduzzi A, 1999, Ann Ital Med Int, V14, P46
[9]   Acquired haemophilia A: errors in the diagnosis [J].
Kazmi, MA ;
Pickering, W ;
Smith, MP ;
Holland, LJ ;
Savidge, GF .
BLOOD COAGULATION & FIBRINOLYSIS, 1998, 9 (07) :623-628
[10]  
Kitchen S., 2009, QUALITY LAB HEMOSTAS, P81