Analysis of alternative parameters of dynamic resistance measurement in high voltage circuit breakers

被引:12
作者
dos Santos Sousa, Herbet Filipe [1 ]
de Oliveira, Adriano Costa [1 ]
Rocha Xavier, George Victor [1 ]
de Santana, Henrique Nunes [1 ]
da Costa, Edson Guedes [1 ]
Ferreira, Tarso Vilela [2 ]
机构
[1] Univ Fed Campina Grande, Campina Grande, Brazil
[2] Univ Fed Sergipe, Aracaju, Brazil
关键词
wear; electric resistance measurement; electrical contacts; circuit breakers; dynamic resistance measurement; high-voltage circuit breaker contacts; inevitable degradation processes; electric arcs; current interruption capacity; operational faults; efficient evaluating techniques; degradation level; HVCB contacts; static resistance measurement; main contacts; arcing contacts; mean resistance; DRM curve; AC degradation; nonstandardised technique; specified parameters; DRM technique; continuous evaluation; HVCB ACs; real wear conditions; CONTACT RESISTANCE;
D O I
10.1049/hve.2019.0046
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Throughout its lifetime, high-voltage circuit breaker (HVCB) contacts suffer from inevitable degradation processes, especially during the formation of electric arcs. Highly degraded contacts can reduce the current interruption capacity and increase the chances of operational faults, which might lead to considerable financial losses. Therefore, the use of efficient evaluating techniques is a key factor to achieve systems reliability. The dynamic resistance measurement (DRM) is a technique that can be used to evaluate the degradation level of HVCB' contacts. It stands out from the usual technique, static resistance measurement, by allowing the assessment of both the main contacts and the arcing contacts (ACs). Usually, the mean resistance or the area under the DRM curve is used to estimate the AC degradation. However, DRM is a non-standardised technique and there are no specified parameters to evaluate the real wear conditions. Therefore, an analysis of alternative parameters extractible from the DRM technique is presented in this study, such as amplitude and variance of the DRM curve. The results attest the possible use of more than one parameter for the continuous evaluation of HVCB ACs, characterising the DRM as a more complete and precise diagnosis tool.
引用
收藏
页码:197 / 202
页数:6
相关论文
共 21 条
[1]   Intelligent Failure Diagnosis for Gas Circuit Breakers Based on Dynamic Resistance Measurements [J].
Abdollah, Mohammad ;
Razi-Kazemi, Ali A. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (09) :3066-3077
[2]  
[Anonymous], 2015, THESIS
[3]  
[Anonymous], 2015, THESIS
[4]  
[Anonymous], 2007, 622711 ISIEC
[5]  
[Anonymous], 1999, C3709 ANSIIEEE
[6]  
Bagherpoor A., 2016, T POWER DELIVER 0802, V32, P1776
[7]   Electrical erosion test and condition assessment of SF6 CB contact sets [J].
Chen, Gong ;
Lan, Lei ;
Pan, Zhuohong ;
Wen, Xishan ;
Wang, Yu ;
Wu, Yang .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (08) :1901-1909
[8]  
Claesson L., 2007, IMPROVING EFFICIENCY
[9]   THEORY OF HARDNESS AND MEASUREMENTS APPLICABLE TO CONTACT PROBLEMS [J].
HOLM, E ;
HOLM, R ;
SHOBERT, EI .
JOURNAL OF APPLIED PHYSICS, 1949, 20 (04) :319-327
[10]  
Jeyaraj S.G., 2011, IET C REL TRANSM DIS